Hi to all.
I have a two problem.
I've a server with 2 disk in raid 1 with this logical drive status: Ready for rebuild.
But rebuild does not take place.
Yesterday IML logged this event: "Drive Array Device Failure (Slot 2, Bus 1, Bay 1)",Drive Array Subsystem,Critical,1,21/08/2014 12.36,21/08/2014 12.36
but
thi is the result of ADU:
disk0: Last Failure Reason: 0x07 (Drive timeout)
disk1: Last Failure Reason: 0x05 (Mark bad operation failed)
............not bad............
It seem that both drive have problems...
Have you to seggest some way to resolve replica issue?
What is the active disk with true data?
Actually I can't upgrade firmware because I can't have phisical access to the server (prod server i nanother location).
HD MODELS:
HP 36GB 15K Ultra320 SCSI Pluggable BF03688284 Hard Drive
CONTROLLER MODEL:
Smart Array 641
tnx