Smart Array 641 RAID 5 Rebuild Pending

$
0
0

I have a ProLiant ML350 with a Smart Array 641 and 6 HDD's.  2 x 72.8 Gb and 4 x 146.8 Gb

 

There is NO Backup at the moment. 

 

The original configuration was:

 

2 x 72.8 Gb, 1 logical drive, RAID 0, Operating System (Server 2008 32bit) (ID 0, 1)

1 x 146.8 Gb, 1 logical drive, Misc Data Drive (ID 2)

3 x 146. Gb, 1 logical drive, RAID5, Primary Data Drive  (ID 3, 4, 5)

 

The drive ID3 was failing and it was removed from the server. The server used the RAID5 with only ID4 & ID5 for 2 days.  However, half of the data was missing.

 

I have a new replacement drive and have attempted to run a rebuild.  The RAID5 controller get's rebuilt, but stays on 0% when going to recover the logical drive.

 

Is there anything I can do?  The original drive still powers on, is there a way to temporarily get the data accessible in order to run a backup?

 