I have 3 new DL380p Gen8 which I updated to latest firmware using SPP and installed ESXi 5.5 (HP image)
I have now joined the servers to an existing virtual center install as a new 3 node cluster.
All three alarm for the the same 5 hardware temerature sensors in Vitual center
- LOM CARD
- PCI 1
- PCI 2
- HD Controller
-System Management Module - iLO Zone
Connecting to the iLO web consoles for the 3 servers I can initally not find these sensors as part of the "Sensor Data" under "System Information" > "Temperatures" . If I then check to "Show missing Sensors" the following are show as Not Installed.
12-HD Max System 5 0 Not installed N/A N/A
27-LOM Card I/O Board 14 14 Not installed N/A N/A
28-PCI 1 I/O Board 13 13 Not installed N/A N/A
29-PCI 2 I/O Board 13 13 Not installed N/A N/A
30-PCI 3 I/O Board 13 13 Not installed N/A N/A
31-PCI 4 I/O Board 7 13 Not installed N/A N/A
32-PCI 5 I/O Board 7 13 Not installed N/A N/A
33-PCI 6 I/O Board 7 13 Not installed N/A N/A
Can anyone explain what is going on here? Why is Virtual Center alarming for sensors that are not installed?
Should they be installed? Are they phyically missing from the server or just missing drivers?
Is this a Vmware Virtual Center problem or a hardware issue with the 3 servers?
Initally the iLO firmware was on 2.02 but I have upgraded to 2.03 and the problem is still there.
If I reset the sensor data in virtual center the problem initally disappears but the alarms re-occur on the next refresh of the sensor data?
Firmware Information
HP Ethernet 1Gb 4-port 331FLR Adapter 5719-v1.38 NCSI v1.2.46.0
HP ProLiant System ROM 02/10/2014
HP ProLiant System ROM - Backup 02/10/2014
HP ProLiant System ROM Bootblock 03/05/2013
HP Smart Array P420i Controller 6.00
iLO 2.03 Nov 07 2014
Power Management Controller Firmware 3.3
Power Management Controller Firmware Bootloader 2.7
SAS Programmable Logic Device Version 0x0C
Server Platform Services (SPS) Firmware 2.1.7.E7.4
System Programmable Logic Device Version 0x32