Stop: 0x000007b When Migrating from DL360G4 to G5

$
0
0

Hi, I hope someone can help me.

My customer has several DL360G4p's that they are wishing to migrate to DL360G5's when ever I attempt a migration im left with a BSOD on boot, the full stop error is.

STOP: 0x0000007B (0xF741B84C,0xC0000034,0x00000000,0x00000000)

This error is an inacessible boot device probably due to the different RAID controllers.

The process I followed for the migration was to use NTbackup to backup the following directories.

c:\windows\*.*
C:\program files\*.*
c:\Documents and settings\**

System State.

A little trick i use to migrate between hardware platforms using different raid controllers is to rename the target raid driver sys file to that of the source server. In this case, I renamed the driver for the G5 (HPCISSS2.SYS) to the driver used by the source (CPQCISSM.SYS). This process has always worked in the past but between these platforms this process also fails.

I have also attempted to migrate using Acronis Universal restore, this software alows you to load drivers for the target server during the restore but this also fails.

Any assistance you could offer would be great.

Thanks.

 

 

P.S. This thread has been moevd from BackOffice Products to ProLiant Servers (ML,DL,SL). - Hp Forum moderator