ML350p Tower + P800 + P822

$
0
0

Hi!

 

I'm writing this in the hope it will help somebody.

 

We have a ML350p gen8 tower server. We wanted to install one P822 controller and also a P800 controller on the same board.

 

We have Storage Controllers (P4xx) onboard, Slot 1+ Slot 2.

 

The only setup we were able to find and work was intalling P800 in Slot 3 and P822 in Slot 4.

 

P822 can only be installed in Slot 3 or 4, but when installed in Slot 3 the Slot 4 must be empty. Also, when the P800 is installed in any of the slots from 5 through 9 there is an undocumented Boot Error "1783-Slot 9 Array Controller is in a lock-up state due to a hardware configuration failure.".

 

Undocumented because the P800 works fine in Slot 9 until the P822 is inserted!

 

Because P822 does not support MSA50 - we were forced to keep both controllers. 

 

In case this helps somebody... maybe it can also be added to customer advisories, so as people know about this!

 

Regards,

 

Mihai Ionescu


Viewing all articles