Replacing HP P410 with P420 and keeping the data
hi Would it be possible to replace HP P410 raid card with a HP P420 raid card while keeping the data? because my hp p410 is fault. and i can not find new p410 . i can buy p420. my server is DL380 G7....
View ArticleML310E Gen8 V2 - AMS Service Error on Debian/Ubuntu
I keep getting the below error every second after installing the HP Agentless Management Service on Debian 7 / Ubuntu Server 14.04.2 LTS Loading kernel module for a network device with CAP_SYS_MODULE...
View ArticleHP Smart Array B110i RAID 0 to RAID 1 Migration
I've recently inherited a server to support and I'm after some advice on migrating a RAID 0 set up on the Smart Array B110i to RAID 1. The server is a HP ProLiant ML110 G6.The current server has a...
View ArticleNew Smart Array Installation Cabling
I have a DL380P Gen 8 with an additional P220 HBA (2x internal mini SAS ports) that I need to cable up to the drive backplane, but I can't seem to find the correct cabling, or may I just don't see how...
View ArticleProliant DL360e gen8 raid 1 sync after swap hdd
My company just bought new HP Proliant DL360e gen8. I just config Raid 1 and need to know if the HDD faulty and need to swap with new HDD it is need to install any software for new HDD sync the data....
View ArticleDependencies of hp-health-10.10-1710.30.rhel6.x86_64
hello,i am facing issue of dependencies when trying to install Hp-health below are the dependencies appreciate you r help. rpm -qp -requires hp-health-10.10-1710.30.rhel6.x86_64 .rpmwarning:...
View ArticleSmartArray P400 (and P400i) - Enabling No-Battery write cache - Works on...
Heres what I have:- Server1 - DL360 G5P400i embedded - firmware v7.22Battery status = Failed Server2 -Dl380 G5P400 in slot 1 - firmware v5.26Battery status = Failed On Server1, in ACU, if I go into...
View ArticleHP System Management homepage - Cannot display the webpage
Windows 2003 Server.Not getting anything on https://127.0.0.1:2381/ or https://localhost:2381/Both SNMP and HP System Management Homepage (v7.3.3) services are running.What to check first? Or just...
View ArticleProLiant ML310e Gen8 v2 CPU Temperature Stuck at 40*C in iLo and SNMP
I have four ProLiant ML310e Gen8 v2 servers. On each of the servers the reported CPU temperature from iLo and SNMP is always 40*C and never changes. I've tried clearing the NVRAM and restting iLo which...
View ArticleHP Servers Expert Day on April 28th & 29th
Hello Everyone, Back by popular demand, we are hosting our next HP Servers Expert Day on April 28th & 29th. Please mark this on your calendar. Join the HP Support Forum and post your questions....
View Articleproliant dl360e gen8 a second processor
Purchased a second processor for the server hp proliant dl360e gen8 (668814-421) - Intel Xeon E5-2407 2.20Gh . Memory for a set. When the server boots, I get an error: 245 Proccesor Power-on Issue:...
View ArticleSFF Drives in a ML350 Gen 9
I need a server for a project and I'm looking at getting a ML350 Gen9 fitted with a P440ar/2G Smart Array and 8 SFF SAS drives as that is what is currently available on the shelf of my local supplier...
View ArticleUpgarade ML350G6 to Xeon X5672
Hi I´m about to upgrade an ML350 G6.I would like to install a Xeon X5672 (3.2 Ghz), replacing a Xeon E5606 (2.13 Ghz)Could anyone recommend, which modules of ram tu use to obtain 16GB.No special...
View ArticleiLo Embedded User Partition
Hello, I just have a little question. I search on the net without result.In the Proliant Server G9 it's possible to make in the iLo an Embedded User Partition with 1GB and install the ESXi 5.5. But...
View ArticleIs firmware update for Network and Smart Array Controller P420i possible via...
We have some bunch of bare metal DL380p Gen8 servers and I am working on updating the firmware for different components. I configured the iLO4 and upgraded the firmware for iLO4 from 2.07 to 2.10. I...
View Articleproliant 370 G5 battery failure issue
Am getting a battery failure error on Proliant 370 G5 server. OS installed is server 2003. I have replaced the battery with the new one 2 times, and i have also waited for around 48 hours after...
View Articlehelp with G9 teaming
Pulling my hair out here! We have new G9 servers (380, 360 etc) and configuring our build to work on these hardware - everything is scripted/automated. I noticed that NCU is now no longer supported! We...
View ArticleWhole Server and iLO is slowing down, because of big iLO AHS Log
Yesterday the SIM Server notified that one of the iLO is no longer reachable.Trying to reach the iLO Web Console shows a very very slow responding.Than we see troubles with the Virtual Servers, as with...
View ArticleHP OneView for vmWare vCenter 6
Is there a OneView for vmWare vCenter that works with vCenter 6?
View ArticleHP G4 RAID 5 statuts failed
Hi,Please help!!!We have one of our HP G4 server wich don't boot.We have the error message : logical drives) disabled due to possible data loss.We checked the array configuration and find that the raid...
View Article