Disk controller for ML350
Hello, I have a ProLiant ML350 server at home that I use as a file server. I recently bought four 4TB drives for it to upgrade storage. What I did not check is that the onboard HP Smart Array E200I do...
View ArticleHP Intelligent Provisioning 1.62 and Server 2012 R2 family OS
When installing Hyper-v server 2012 r2 with IP 1.62, IP detects 2012 R2 family OS.If i select windows server 2012 r2 Standart OS - it seems to be ok.But if i select Hyper-v server 2012 R2 (wich i...
View ArticleIs it possible to upgrade my ml150 G6 to quad core CPU?
Hallo:I currently have a ml150 G6 with a dual core CPU e5502. I wanted to find out if I can upgrade it to two quad core CPUs e5530.The S/N is 519728-001Thanks!
View Articlesnmp monitoring on DL380 G9
Hi Running CentOS 6.6 (32bit) and the latest hp-snmp-agents installed (hp-snmp-agents-10.20-2789.26.rhel6.i686). Having issues with snmp monitoring. It works fine and after a while snmpwakl has a...
View ArticleDL360G6 / Smart Array P410i / numbering bay / numbering hard drives front
hello,the system management show me on the Physical Drive - Port 1I Box 1 Bay 7 status failed.i have a raid 1 with 2 hard drives. on both hard drives the blue led blinks. nothing happens when ipress...
View ArticleHP Proliant DL375 G1 hp-health
Hi I am trying to install hp-health on a server with Debian (jessie) on it. However the installation fails due to missing "hpasmd" command. The /opt/hp/hp-health/bin folder contains some binaries, but...
View ArticleHP SmartSTart hangs at this screen upon booting... Help?
Trying to boot my DL380 G6 with the SmartSTart 8.70-B and it hangs at this screen: (please see attachment) Anyone have any ideas?
View ArticleP812 Array Accellerator disabled
We have a P812 controller in an Se326M1 (DL180 G6) and the array accelerator is disabled. Output from the CLI is this: Cache Board Present: True Cache Status: Permanently Disabled Cache Status...
View ArticleFBWC on Proliant ML350e in RAID10 makes any sense ?
Hi, I have an ML350e running and I'm wondering if I will really see any difference when installing a 512 MB FBWC module on the B120i RAID controller ? The controller is configured for a RAID10 array...
View ArticleProLiant ML110 G5 ready for W2K12R2?
Good morning from Germany. I've got a short question. I've taken over two networks in my company. One network is running the ProLiant ML110 G5 Servers on W2K8R2.From our Enterprise Admins I have to...
View ArticleH240ar upgrade to P840, data loss?
Hello forums, could someone please clarify, is Simple RAID 50 created by H240ar Smart HBA in raid mode compatible with Smart Array Controller P840? Or upgrade to P840 means blanking all drives and...
View ArticleHP DL370 G6 - UPGRADE CPU or Motherboard?
I am looking to purchase a HPDL370 G6 from a friend (used). It currently has 2 x Xeon W5580 Quad core CPU @ 3.20 ghz.It will be used as: 1. NAS server2. Plex transcoder3. General use Question is: 1....
View ArticleHP ProLiant ML110 G7 - P212 Smart Array RAID
I created my four 4TB hard drives to RAID0 using my HP Smart card. I had a 12TB logical volume. Then when I added my datastore storage using HP vSphere client, I was only able to create a 10.92TB...
View ArticleAdd Secondary smart array on ML 350 g6 to add a second Bay drive
Hello, We are triing to add a second bay drive on a ML 350 g6. There is a Smart arry P410i on board and we are triing to add a second P410 on a pci slot to have the extra SAS. the bios as been...
View ArticleHP ML350 Gen 9 - Power Supply redundancy with x4 RPS enablement kit
Hi. I got an ML350 Gen 9 with 3x 800 Watts PSU. Per review on HP Power Advisor max power load is around 750 watts. 1x 800 Watts PSU should be able to power up the server. I plug one PSU, the server...
View ArticleML380p Gen8 fan load problem
hii have a HP ml380p-gen8. i installed ESXi 5.5 on the server and every thing was ok. today i put 2 new HDD in server, go to p420i controller and made a new pool. (before i just have 2 HDD ) after ESXi...
View ArticleML350G9 - Expand RAID 10 over two cages
Hello, I have the following situation: ProLiant ML350 G9 with an RAID10 over 8 SFF disks on the first cage. It used the internal Smart Array P440AR.Now I have put a Smart Array P840/4GB controller and...
View ArticleAdd more drives to G1610T microserver
I bought a G1610T microserver a couple months ago to make a media server using xpenology. This allows upto 12 drives, but of course this server only have space for 4. Does anyone know of any way to...
View ArticleML380p Gen8 fan speed problem
hii have a HP ml380p-gen8. i installed ESXi 5.5 on the server and every thing was ok. today i put 2 new HDD in server, go to p420i controller and made a new pool. (before i just have 2 HDD ) after ESXi...
View ArticleChanging Mirroring RAID disks
Hello .. I have a DL380 server with raid configured as mirroring with only two harddisks ( 0 and 1) As we lost some files due to a software bug I removed both the HD's ( 0 and 1). Instead I put an old...
View Article