No disk drives detected on DL380 G9 with B140i
Im having a similar issue on a brand new out of the box, HP DL380 Gen9, whereby the Array B140i shows up as working, but when i try and run the configuration, it keeps telling me there are no physical...
View Articlee200i on Raid 5 logical drive Parity Initialization Status at 0%
Hi there, I have a HP ML350 G5 where we have replaced a failing HD in a Raid 5 array of 3 disks, the replacement drive has synchronised but in ACU it still shows a information alert for the Parity...
View ArticleHost bus adapter H222 and RAID for Prolian DL380e Gen8
Hello,I have server DL380e Gen8 (P/N: 648255-421) with B120i RAID controller and H222 Host Bus Adapter with attached tape drive (LTO 5). Up to now I was using configuration with 4 LFF SATA drives. Now...
View Articlehow to check ipv6 gw info from ilo4
hi,I would like to check the Ipv6 address and Gw informatio via ilo4 console. we are using ILO FW- 1.51 Jun 16 2014ther reason is we inable launch ilo via web so we need to check if there is any ipv6...
View ArticleProliant ML350 G5 E200i controller failed battery message cannot be remedied
I get the message below for the E200i controller on the system. Even though the battery voltage checked out, I bought a replacement, and the message stayed the same. So I got a brand new controller...
View ArticleStand alone remote console for Linux systems
Hello,Is there a HP stand alone remote console for linux? Similar to HPLOCONS for windows http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f842ceb31cf48d392e22705a8?I looking for a stand...
View Articleget ahs logs using scripts
how to get ahs logs when there is no ilo GU access. we are using linux os in blade where we can loign normally. ThanksNag
View ArticleML350p G8 P420i Additional Drive Cage
Hello,I have an ML350p G8 Server with an LFF Drive Cage with 6 x 1TB SAS. But soon i need more Disk Space.It's possible to add an second LFF Drive Cage to the P420i Controller?Thanks for Help
View ArticleML330 G6
I bought a new External Tape LTO 3000 ultrium but my SAS controoler (P410 if i recall correct) dont have Externarl Port.I search for P212 but seem to be in "no sold anymore" state.My question is: can i...
View ArticleSystem currently defaulted to typical configuration settings ?
Hi,I've got Proliant DL 360 G7 which is behaving erratically, it always lose the iLO configuration (IP address kept on changing by DHCP) and everytime I reboot the server it always taking so long time...
View Articlep212 controller allows only two logical drive creation? Wht is the solution...
Hello,Currently my zero memory p212 card, can only create two logical array. If I buy, 256 MB memory board, can I add two more disk and create four arrays?
View ArticleML350Gen9 IP2.30.275 server2012r2 "Windows: not supported"
Hi Everyone,Every search I have made on this has no reference to the above error or relates to other issues entirely.Have taken dleviery of new ML350gen9, and in trying to install Server2012r2 Eval iso...
View ArticleDl380 Gen9 Won't boot after reboot. - It was just fine before!
HelloI have a DL390 Gen9 that after a reboot, it wont boot into windows. I have an OCZ Revo Drive and 6 - 2.5" SAS drives in a RAID5 with a hot spare. The OS is on the Revo Drive with Windows 2012 R2...
View ArticleXeon E5 1650v3 with ML150
Hi,Can i swap my 2609v3 for a 1650v3 if i don't want to use dual CPUs?Does ML150 support that CPU and can i use the passive heatstick that are mounted on 2609v3?
View ArticleDL380G9 10-Gb-533FLR-T iscsi Esxi6 iscsi tcp offload aka hardware dependend...
HiI have installed a new dl380Gen9 with a HP FlexFabric 10GB 533FLR-T Adapter onboard.I Used the HP Customized ESXi Build and updated the Server with the last SPP from Oktober.After the sucessfully...
View ArticleProliant DL360 gen9 Post code 711 stale during BIOS
Can't boot server. Stop on Post Code 711.There are two D3000 (x12x6TB SATA) shelves connected to the server.
View ArticleSAS Cable for ML150 G9
Hi,Is the cable 729106-001 for use with Two 4-LFF cages but only using one 8087 SAS Port?
View ArticleML110G7 and B110i controller
After a crash of our backup server which is a ML110G7 with integrated B110 array controller attached to 2 x SATA 160 GB drives in RAID level 1, we are unable to boot from disk running W2K8R2. So we...
View ArticleHP QLogic NX2 10/20GbE Multifunction Drivers fails during SPP installation
Hello,The Installation with SPP 2015.10 fails with package cp025087.exe (HP QLogic NX2 10/20GbE Multifunction Drivers for Windows Server x64 Editions 7.12.41.0 1 Okt 2015) on a Proliant DL385 G7 Server...
View Articleporliant Dl360 G9 how to make partition throw intelligent provisioning
Hello,we have HP server G9 DL360, i installed windows server 2008 R2 through intelligent provisioningbut did not allow me to select partition drive like (C: and D:)please help me to slove this...
View Article