Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Browsing all 10362 articles
Browse latest View live

DL380 G5 - CPU upgrade E5335 to E5472 No Video

Hi,I have a pair of Xeon E5472 CPUs I wanted to use to upgrade one of my DL380 G5 servers but after doing so I get no video, all fans run at 100% and iLO thinks the old CPUs are still in there while...

View Article


HP DL360 G4p - maximum possible SATA HDD capacity

We have obsolete HP ProLiant DL360 G4p server with 2x SATA HDD of 500 GB.According to the HP Product Bulletin, the highest possible option for this server is HP 750GB 1.5G SATA 7.2K 3.5" HDD.My...

View Article


ASR debugging

Hey there,I am new to HP servers, and I was reading up on the ASR feature. I suspect that this feature is responsible for our sudden server reboots and would like to know how I can find out if this is...

View Article

Need more space

I have a DL380 G5 with a Smart Array P400 and am running out of space on one of my drives. There are 3 arrays made up of 8 disks. The array in question is RAID 1+0 and made up of 4, 146GB SAS drives....

View Article

MIB Change on Proliant G8?

Hi,I'm trying to add the OID to monitor HP physical disks status on my DL380 G8 with WIndows 2012 and MIB walker tool cannot find anything for this model. I am using  OID 1.3.6.1.4.1.232.3.2.5.1.1.6...

View Article


Hyper-V 2012R2 Core with SMHP and SSA

Hello,i've just setup a ML310eG8v2 with a P212 and as a OS Hyper-V 2012R2 Core. Systems is running good, but i want to monitor the RAID and the System. So i want to install System Management Homepage...

View Article

RAID 1 + TRIM on Smart Array B120

Hi there,We have a ML310e ProLiant Gen8 server with a Smart Array B120i controller and two 1TB hard drives configured in RAID1.We want to replace the hard drives with solid state drives, is it possible...

View Article

DL380 Gen9 BIOS Upgrade

Hi AllI  need to upgrade BIOS in our DL380 Gen9 to avoid problems with Timezone and DST.I've got the Online ROM Flash Component  (1.52_11-10-2015(2 Dec 2015), and we're planning to upgrade as soon as...

View Article


DL380 G8 - Fan Speed Increase when adding expansion card

I've noticed when adding a expansion card (NIC) into my DL380 G8 the fan speeds increase, I've installed the newest HP Service Pack with the latest drivers, tried a few different cards in different...

View Article


Server 2012 Gen8 - User profile service failed the logon

moved to Software=>Products=>PC Software=>ITRC Remote Lights-Out Mgmt (iLO 2, iLO, RILOE II) Forum

View Article

HP ML110 Server reporting incorrect memory

Hi, My HP ML110 is report that it has 8GB of memory when it actually has 16GB. Can you please advise what I can do to fix this issue? Thanks

View Article

Server 2012 R2 on ML310e

I have a HP Proliant ML310e Gen8 v2 Server with a B120i RAID Controller.   There are 4 2TB hot swap SATA 6Gb/s 7200 rpm drives.   I am configuring the RAID 1+0 for the system.   This server will be...

View Article

Proliant DL380 G7 Won't Start Without Both Power Supplies

Hi, I have an HP Proliant DL380 G7 that has dual 460 watt power supplies.  If I have both power supplies plugged in at the same time, then the server will boot and get through the POST just fine.  If...

View Article


DL360 Gen9 and write caching

We have a DL360 Gen9 that we need to enable write caching on with Windows Server 2012R2. I can definitely confirm it's on on the controller using the Smart Storage Administrator but whenever I try to...

View Article

Power supply for DL360

Hi,I am purchasing the following profile and need to know if I can use the 500W power supply or do I need to go to the 800W?(1) Proliant DL360 (G 9) Rack Server/TV Xeon E5 (2620) 2.4 GHz 16 GB (No HDD)...

View Article


HP DL380 G6 RAID 1+0 - 2 drives, both predicted failure - Will not rebuild

Hi there,I have inherited a HP DL360 G6 that is displaying 'Predicted Failure' on both of the two drives in the RAID array.I attended the server location today with a new drive and HOT swap replaced it...

View Article

DL180 g6 running Open-E RAID Software - Cache Controller Failure

Hello,I've recently taken over as IT Director at a small school district for someone that unexpectedly passed away.  I'm currently the only full-time IT person at the school.When in the CLI for my...

View Article


Proliant gen8 don't recognize 2 x 8gb ram

Good morning,I've a MicroServer proliant Gen8 with Intel(R) Xeon(R) CPU E3-1220L V2 @ 2.30GHz processor.Total memory is 16 gbProcessor 1  1   Good, In Use  Yes  647658-081   DIMM DDR3  8192 MB  1333...

View Article

Proliant ML 350 G6

My servers are losing connectivity. I have 4 servers in the network, two of them are Proliant ML 350 G6 servers and they are losing connectivity with each other. One is the domain controller, one is...

View Article

How can I get the SAID for a old product sot that I can access the...

HiI tried to download the lateest BIOS for my DL360 G5, obviously, I am not allow to download it without a service agreement or warranty or something else.Here is the question: How can I get the...

View Article
Browsing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>