HP 331FLR Network Self Test Error Code: 604304
HiUnfortunately,the Insight Diagnostics test On intelligent provisioning version 1.61 runon the servermodel DL380p G8 & DL360p G8 With 331Flr that update With SPP 04/2016, Network Self Test on All...
View ArticleHow is disk activity time calculated ?
Dear community,When I run HP SMART Insights utility and diagnose my disks, it says that such disk has X months of activity.Is activity = age ?Suppose I bought a disk 5 years ago but only used it for 1...
View ArticleSNMP and temperature data in Windows 2012 R2
Prior to upgrading our Proliant Gen8 server to Windows 2012 R2, I was able to get the temperatures of the system via SNMP by querying the IP address of the server (10.0.0.2). After the install for...
View ArticleHP Proliant DL380 G7 faulty hard disk not picked up by any applications..
HiI wontder if anyone can help.I have an HP DL380 G7 server running Vmware ESXi 5.5.0 OEM. I noticed that one of the HDDs had developed a fault as the red light was on. I had checked HP SIM (running...
View ArticleHP H241: HPCISSS3 Event ID 5008 and 129 during backup to MSL2024
Recently I noticed HPCISSS3 events 129 in companion with 5008 in the Windows System Event log during backups,The events indicate that a SCSI reset is being isued on the H241 HBA to which a MSL2024...
View ArticleDL380 G7 BIOS update issue
I have a G7 with BIOS version P67 07/02/2013. I tried a couple of recent SSPs but none of them updates the BIOS for some reason. Can someone please suggest a solution to that?
View Articlehp dl380p gen8 ram
i have dl 380p gen8 server. cpu1 2x16 gb ram and cpu2 1x16gb ram. is it correct ram configuration ? just want to learn is there any problem ram configuration ?we are using esxi 5.5 on dl 380p gen8
View ArticleLatest bios version for SE316M1
I have bought a HP SE316M1 server.I cannot find any drivers for it.I have found links on the Internet which link to the old hp.com site instead of hpe.comI found that HP SE316M1 servers are similar to...
View ArticleHP SmartArray P420 "Ready for Rebuild" problem
Hi everyone.As i have already searched the "big bad internet", and found that this error is verry bad in deed.But my issue is a bit diffrent, that i actualy only have one failed drive.I will try to...
View ArticleDoes this 2gb write cache module for P controllers work with the p411?
i have a dl380 G7 with a p411 card and I am curious if the 2G flash backed write cache ,opulent will work in it they look the same, but I don't want to buy it if it won't work
View ArticleHP Proliant ML150 Windows drive locked
hy,I'm configuring a set of 5 servers to replace an industrial SCADA system.Today we finally received the extra RAM sticks we ordered, to install those I powered down the servers and installed the RAM,...
View Articlekernel power
The server has rebooted four times twice a year, it's Proliant ML310eGen8v2, i have no smart array. The server manger software (windows server 2008R2) says:The system has rebooted without cleanly...
View ArticleMoving RAID 10 array from a DL380 G6 to a DL380 G7
I have a server that I would like to move the RAID from one server to another so I can retire the G6. For the most part, the data on the storage part of the array fine (RAID 10, 6 x 1.2TB), if It got...
View Articleram configuration for dl360 g7
HelloI'm trying to install 4 - 4GB sticks of ram into a DL360 G7 that already has 4 - 4GB of ram. I tried various slots includingABC DEG GH and also ABC DEF, but I still get a RAM error during...
View ArticleProLiant DL360p Gen8 ipmi not working
I have an ProLiant DL360p Gen8 server which I want to control with ipmi.When I try to run something against it it says: ipmitool -I lanplus -H $ip -U $user -P $pass Error: Unable to establish IPMI v2 /...
View ArticleProLiant DL380 G6 - won't see drives after failure
I am new to HP and have taken over a server recently. It has an 8 drive bays. They origianlly wanted to add drives to add space because they were out of room. Then, after adding a spare drive to the...
View ArticleStorage Controller P420i
HiWe recently upgraded the firmware on our DL 280p Gen server and now see HpCISSs2 errors on both servers.I was able to eliminate the errors on one of servers by switching to High Performance but the...
View ArticleHyper-V on DL380 Gen 9 E5-2650V3
Hi.I have a D380 G9 server with dual E5-2650 V3 CPUs running Hyper-V on Windows Server 2012R2 Standard. Everything is patched to the latest versions - Windows, BIOS, firmware, drivers etc....
View ArticleHow to install Windows Server 2012 R2 without having smart CD on DL380 G7
Hi All, I have HP Proliant DL380 G7 server and want to install Windows Server 2012 R2 but it is not available in smartstart cd version 8.50, so can anyone please advise how can i install the Windows...
View ArticleInstalled CentOS6.5 to DL20Gen9. However, strange log is output.
Installed CentOS6.5 to DL20Gen9 server configured RAID0.However, strange log is output.cat /proc/mdstat-------------Personalities :unused devices: <none>------------- I confirmed...
View Article