HP Proliant ML350 G6 wont start after power off
Yesterday, I had to power off our server because of maintenance of the electric grid, ups was getting empty.When I tried to power on the server it won’t turn on, I have no leds on at all, all is off...
View ArticleHP System Event Notifier did not notify me of a failed hard drive
Have a Proliant ML360 G6 that experienced a failed drive in a RAID array two days ago. System Event Notifier is installed and setup, yet it never notified me about the failed drive. I only knew about...
View Article1720-Slot 0 Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure
HP PROLIANT ML350 G5 - WINDOWS 2003 R2When I was using 2 hard disk (Raid 1+0) ,it was showing 1720-Slot 0 Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure (Box1: Bay 2) and Green light...
View ArticleWhere/how to complain about a badly-handled hardware support case?
My DL360p Gen8 had a iLO malfunction that required motherboard replacement although the non-iLO part of the machine was fine. It took the 'engineers' 3 visits on 3 consecutive days to fix the problem...
View ArticleHP Redundant Power Supply 399771-B21 and 39771-001 (Are they same?)
We have the following ServerProLiant ML370 G5 with two HP Redundant Power Supply (399771-B21) (One of the Redundant Power Supply is found failed)ProLiant ML350 G5 with HP Redundant Power Supply...
View ArticleProLiant BL460c G7 iLO3 Upgrade
We have an ProLiant BL460c G7 currently oniLO Firmware Version 1.28 Jan 13 2012We want to update this but struggling to navigate the HP Website to get the correct ILO Version to download.We have...
View ArticleProliant DL380 G7 - Not detecting PCI raid controller
HI allI have recently purchased a DL380 G7 for internal dev use. I also bought a Smart array P812 to use with an External MS60 drive array. With the card installed in the PCI Express X8 slot on the...
View ArticleDL585g5 VMWare get PCI Bus Error however PCI slot 1 is empty.
HI There,I have a server Dl585g5 and running VMware ESX5.1. IT is getting critical PCI BUS error - PCI Bus Error (Slot 1, Bus 64, Device 13, Function 0) and results in Panic Screen.However the PCI slot...
View ArticleHP P4300 G2 hang before BIOS
Hi. I have 4 HP P4300 Storages. Two of them hangs during boot and they show nothing on monitor (completely black). The front Led turns red and I can't access the servers. Any suggestion?
View ArticleUsing SSD as cache for RAID array in DL980 G7
I am looking at purchasing a used HP DL980 G7 server with 8 10-core E7-4780 processors. It is to be used for engineering simulation calculations requiring an SMP configuration, as opposed to a...
View ArticleML150 G6 Won't Turn On
Out of Warranty HP ProLiant ML150 G6 Server will not turn on.Solid green on power source.Solid amber power button. There is a solid green LED on the board that is marked "LED1" with "R13" just below...
View ArticleAdd Drives to Raid 10
Hello Everyone, Since I setup the server, ML350p Gen8, I have installed 16 drives of HP 300GB 10K, 8 for the P420i (integrated) and 8 for the addtional P420 (PCIe). Drives on channels 4 and 8 are...
View ArticleDisk Writes/sec and Disk transfer/sec eq zero, for about 6 seconds every...
Hi,The problem I have is on a HP DL 380p Gen8, Microsoft SQL database server with Windows 2012R2. The SmartArray controller P420i has the latest 7.02 firmware, Caching enabled, battery ok, Physical...
View Article"SSD Over Provisioning Optimization" -- how long does it take?
Question summary: How long does 'SSD Over Provisioning Optimization' really take?Background: I'm setting up some new servers with large disk arrays -- 6 x 1.6TB SSDs. I want all my storage in one...
View Articleupdate Firmware bios dl380 gen9
hello,where to find the latest bios for dl380 Gen9 server ?my server is guaranteed and can not download ...there is a padlock ???My opérating system is debian jessie.thank ben
View ArticleDoes the HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter(700751-B21) support LLDP?
Hello, everyone.I work at HPE Porto Alegre/Brazil and we bought a HP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter(700751-B21) to use with a DL Server.I would like to know if this adapter supports LLDP. I...
View ArticleDL380 G6 PCIe- Riser cards
Hello, I have a DL380G6 server that we are trying to add 2x 10GBe interfaces to and needed to install an additional Riser Card to provide the extra PCIe lanes needed. When we booted it up the server...
View Article็How to add new ROM firmware P89 v2.20 into existing HPSUM repository (SPP...
Hi Experts,I found that the SPP v.2016.04 come with DL360 Gen9 firmware (P89 v2.00) which have problem with Smart Array battery module. I have downloaded ROM P89 v2.20 already, and what to add to HPSUM...
View ArticleHPE ProLiant DL180 Gen9 + HPE Smart Array P440/4G: SAS/SATA disks + drives...
Hello,I'm trying to figure out what HP genuine SATA or SAS drives to select for a low cost solution consisting of factory pre-configured:HPE ProLiant DL180 Gen9 (HP Code L9N12A) + HP Smart Array...
View ArticlePerformance of RAID 1 on HP H240 HBA Controller
Hi HPE experts,Very complex hierarchy, however I would first like to know if I am posting in the right Forum on HP H240 HBA Controller on a Proliant ML 150 Gen 9 Server. Please advise if I am not.I...
View Article