Unable to Find Sata Disk while installing Rhel7 in HP DL380 Gen Server

Hi,I have HP Dl380 Gen9 Server with HP Smart Array p440ar integradted HBA/Raid Controller. I don't want Raid so I have enabled HBA mode. After enabling HBA mode and I have start installtion with...

View Article


No inicia Server Proliant ML370G5, pxe-e61 media test failure check cable

Que tal buen dia, Pido de su apoyo ya que no logra iniciar el servidor, el mensaje que me indica esPXE-E61: Media test failure, check cablePXE-M0F Existing Broadcom PXE ROMPor lo que he indagado sobre...

View Article


RAID 0 - NVMe Enterprise SSD in ProLiant Gen9

Upon first setup and install of our new server, the HPE storage management utility, did not recognize my 2 new disks, which i would like to setup in RAID 0 or 1.Using this ProLiant Gen 9 server and 2 x...

View Article

Installation W.S2012 on Proliant DL180 G6

Hello Everyone,I'm trying to install and configure an old Proliant 180G6 that my IT department gave to me, there are 8 new hard drives and no OS installed. I need to configure RAID + Windows Server...

View Article

Image may be NSFW.
Clik here to view.

RAID 6 (ADG) vs. RAID 60 or RAID50 comparison and use case scenario comparison ?

Hi All,I'm confused with configuring the new LUNs for my backup server purpose, so can anyone here pelase share some explanation as to when to use RAID 6 (ADG) vs. RAID 60 or RAID50 ? Smart Array P411...

View Article


tarjeta integrada mastor g220

hola buenas tarde..cambio el sistema  operativo de mi proliant ml310e gen8 v2   para w10  y no puedo conseguir los drivers y co ntroladores de video me pueden ayudar a solucionarlo , le descargo los...

View Article

hp proliant hardware diagnostics UEFI - system health reports

when i launch hp proliant embedded application - hardware diagnostics UEFI the system health report on Memory says Other! what is this Other! means all other items set OK but memory is Other!could...

View Article

DL580G8 and G7 Get-HPiLOMemoryInfo incomplete info

I'm running a sweep to check memory configuration on servers I manage and I found a weird problem where in case of these two models the commandlet Get-HPiLOMemoryInfo doesn't return Memory_Details and...

View Article


Newbie! trying to get my DL 380 G6 to recognize my 24 port Raid controller

Good day!I am a hobbyist trying to make some hardware I have work,  not sure what I am doing wrong at this point.I have a “HP Proliant DL380 G6”  configured for Windows 2k8 R2It has 1TB in storage on 6...

View Article


Image may be NSFW.
Clik here to view.

Intel S3700 SSD drives in Proliant Dl380 Gen 9

I was watching an Openstack presentation where they had in a DL380G9 22 SAS disks (I guess in the front bays) and 4 Intel SSD S3700 drives.My questions are:1- can non-hpe ssd disks be attached to the...

View Article

Re: HP DL360 G8 - server 2012 factory reset server operating system

Hi please advise how to factory restore windows server 2012 

View Article

Can't update ilo2 on proliant ml350 g6 server in windows server 2008

http://i.imgur.com/J1M7UBS.png 

View Article

UPS featuring safe shutdown of DL60 Gen9 Server

Hi,I am looking to pair my HPE ProLiant DL60 Gen9 Server with a UPS that will stay connected constantly and will shut the server down gracefully if the battery charge reaches depletion. My current...

View Article


Upgrade DL380p G8 from SFF to LFF

Hi,I have DL380p G8 Server with 8 SFF bays and a DvD drive in a seperate 8 bay enclosure. I would like to drop 8 x 3.5 SAS drives i have available into the machine. To do this i believe i need to...

View Article

LTO-7 on ProLiant G7

Hello.I have ProLiant DL380 G7  Product ID: 470065-368  y. 2013  dont support LTO-7 (2015) .With Smart Array P410i  and  468406-B21 HP SAS Expander Card with  1 free ext.  SFF-8088.Need to buy LTO-7...

View Article


P440ar & battery: TRIM not supported w/RAID? Battery-backed write cache in...

Hi,We recently bought two DL380 Gen9's (768345-425) which include the HP Smart Array P440ar Controller and HP Smart Storage Battery. Yesterday I was adding SSD's to the machines and noticed in Linux...

View Article

iLO web interface missing information

Hello, i'll try to explain the issue as best i can. I had configured iLO on 2 DL360p Gen8 servers about a month or two ago. They are running ESXi 6.0u2. Today, one of the server fans was screaming, so...

View Article


Big ADU Array Problems with HP ProLiant DL360p Gen8

Hello ppl,it sounds like a joke, but one of my workers missunderstood my order and pulled 6x 146GB SAS drives out of a powered off server, since i was stupid enough to think that this never gonna...

View Article

"Application cannot be start. Contact the application vendor"

I have a prolem in using Remote Control on iLO homepage.Proliant DL380e GEN8.I can not run Remote Control. When i click on .NET, it displays "Application cannot be start. Contact the application...

View Article

How to easily choose the boot like simple computer ?

I try since two day to choose a ssd disk on odd sata for boot.Omv is intalled on. But i can only boot on with F9 after a bios error while server trying to find system.I don't unterstand what the...