dl360 gen9 ,Issue with server 3 fron led blinks 3 times stop and again ,with...

Hello,We currently have issue with server HP gen9 3 front leds blinks 3 times and the power led is redWe tried to replace psu still the same , any idea?video demostrate the issue

View Article


Looking for SoftPaq SP34692 - ProLiant ML110 G4 SATA Configuration Utility

Hi all,I've to reinstall a MS Windows Server 2003 to recover application data in an old ML100 G4 that it has the following...

View Article


366T card is showing degrading after insertion in DL380 Gen9

Hello .We have facing one issue.We have DL380 Gen9 server and we need to get on Ericsson sw level 1.12 So we required add new 366T adapter Card.We had insert Adapter card successfully but we are...

View Article

Problem with SPP one ml350 gen10

Hello,i'm having a problem while trying to update firmware on HP server ml350gen10.i've downloader the SPP iso (bp-Convenience-download-201809-0.iso) , made a bootable key with this it and plugged the...

View Article

Embedded Flash error gen9

Hello, We have a WS460c gen9 blade. For a while it has been reporting the degraded status on the storage section. Intelligent Provisioning is not available and while we tried using a recover image for...

View Article


HP Proliant DL380 G7 Xeon ES649

HelloI booted the Dl380 to see what was there. The DL380 was in storage for several years. The company needs to sell it but needs to remove company data. I am unable to vSphere client. Without altering...

View Article

HP DL360 with NIC Board 560 SFP+ compatibility with other SFP + vendors

Hi everyone!I have server HP DL360 with NIC Board 560 SFP+  but I have no original HP SFP+ SingleMode 1310, only multimode. Does anyone know can i use SFP+ from another Vendors (Huawei, Cisco, Juniper...

View Article

Uncorrectable Machine Check Exception (Processor 1, APIC ID 0x00000000, Bank...

i have some issue while i reboot a server HPE DL380 Gen10. it says :Uncorrectable Machine Check Exception (Processor 1, APIC ID 0x00000000, Bank 0x0000000A, Status 0xBE200000'000c110A, Address...

View Article


Ml310 G8 v2 freeze in boot process

Hello! Everybody.I'm having one problem with my server ML310 G8 v2, The boot was normally, but since I'm trying to boot a USB imagem, the server freeze in boot process, more specificly in "Early PCI...

View Article


Image may be NSFW.
Clik here to view.

Windows Server 2008 R2 won't boot after install on HP ProLiant BL460c G6

I created a bootable SmartStart USB drive, then I copied the retail Windows Server 2008 R2 iso to the root of the USB drive. I booted off the SmartStart USB drive and I was able to install Windows...

View Article

DL390 Gen9 - Adding RAM

I have two HP ProLiant DL360 Gen9 servers (Intel(R) Xeon(R) CPU E5-2650 v4 @ 2.20GHz) that are our VMWare cluster. I need to upgrade the RAM from 128GB to 256GB. Is there an easy way I can get the...

View Article

DL360 Gen9 - Adding RAM

I have two HP ProLiant DL360 Gen9 servers (Intel(R) Xeon(R) CPU E5-2650 v4 @ 2.20GHz) that are our VMWare cluster. I need to upgrade the RAM from 128GB to 256GB. Is there an easy way I can get the...

View Article

GPU for DL360 Gen9

Hi,We have a requirement to have a graphics card in a DL360 Gen9. It doesn't have to be anything fancy - something like this would doHas anyone tried this? We have a Gen8 we can test it in, but we...

View Article


Help to get BIOS for ML370 G5

Hello,I m not a pro, I am just a Linux enthusiast, I got a ml370 g5 from "trash" , I fixed it, It's working, I just only need one fw, the bios FW SP73053.exe  at...

View Article

SD Card for VMWare boot on DL380p gen8

Hi,Im having a hard time sourcing the original SD card for the DL380p Gen8. Can I use a 3rd party SD card for this and if yes then what would be a recommended 3rd party SD card?

View Article


Server end of life

We have a server and not sure if the technical support is still provided. Could you please specify the end of life dates for the НР 470065-095 DL 180G6 E5504?Thank you in advance!

View Article

Use the HDD/SDD Model Number matrix to locate the latest firmware for your MSA

Ensure your HPE MSA drives are running current firmware. Use the HDD/SDD Model Number matrix to locate the latest firmware for your MSA array.Based on your model number, this reference matrix provides...

View Article


please provide command where we can differenciate between gen10 and gen9...

please provide command where we can differenciate between gen10 and gen9 virtual machine via linux command . Machine HP here is virtual not Baremetal .

View Article

Intelligent Provisioning and VLAN Tagging

Hello everybody,does anyone have an idea or know how to configure VLAN tagging in Intelligent Provisioning?I want to use IP firmware updatesHowever, VLAN tagging is configured on the swichtports and...

View Article

Smart Path and Smart Array caching

Its unclear to me if enabling Smart Path for an SSD array (RAID1) also implies that Controller caching for that array is disabled. This is what I want; I want all the controller cache to be used by the...

View Article