Firmware Update NOT

When trying to use the intelligent provisioning to update firmware on a Dl385p G8. I select Bios update chose to continue following the warning that the process cannot be cancelled and then i get an...

View Article


Transferring Files From Windows Server to ESXi Host(s)

I'm trying to follow the instructions HERE at HP so that I can install the HP ESXi Utilities Offline Bundle for ESXi 5.0 and (hopefully) fix an iLO issue I'm having.  Upfront, no I can not go to the...

View Article


ML350 G6 can't see BBWC

I've installed the BBWC 512MB upgrade in a ProLiant ML350 G6, but when I look at the p410i Controller Settings, it doesn't show any batteries as being installed.  If I go to Diagnostics, it shows my...

View Article

HP Ml350e G8 Ram Upgrade Problem

Hi All, I'm attempting to upgrade the ram in my ml350e G8 from its stock 4Gb to 12GB by adding two 4GB ddr3 1333 ECC dimms. The orginal memory is smart memory but the dimms im adding are not.  If i use...

View Article

HP MLXXX with SAS

We are looknig to provision a new server for our customer. They currently have 10 users but are hoping to expand to 20 over the next 2 years. I only sell HP servers but cant find one that fits my...

View Article


Server monitor output shows black and white vertical lines, cannot RDP . 3...

My DL380 G5 had three hard drives with amber lights showing failed. I removed the 8th one since its fan was making a really loud noise. After removing it everything on the server still seemed to work...

View Article

Internal Storage Controller Overheating ( Temperature Sensor 3 , Location...

I now have multiple ML350e Gen 8 Servers that are coming up with this error and a amber light on the front of the case ( amber light flashing on health light ) Tech support has had me upgrade frimware...

View Article

HP Proliant DL380 G5 update firmware for component: dg072abab3

Hi, Wondering if anyone can help.  I have said server and recently we inserted a new hard-drive: DG072ABAB3 HP 72GB 2.5".At the POST screen there is a message requesting that we upgrade the firmware...

View Article


Upgrading from RAID1 to RAID5, possible?

Dear all, I manage a HP Proliant ML 350G6 running Windows Server 2008R2 with over a 79Gb RAID1 (2 * 79GB). Is it possible to move from the current Raid1 to a Raid5 without lossing any...

View Article


Windows Server 2012 setup on a 6TB RAID 5 Partition?

HiI´d like to install Windows Server 2012 std. or Windows Server 2008 R2 on an DL380p Gen8 server with a RAID 5 partition (8 x 1TB disks).Windows creates one partition (in my case 100GB for System),...

View Article

E200 Smart Array failed drive

I have a proliant ML3xx(not sure exact mode)l with 3 x 250 gb hot swap sata raid 5 hard disks, the middle disk looked as if it was failed as the red light was on. I put in a brand new hp drive today...

View Article

The controller reported an error threshold on critical performance unit

please can someone help me, I have 03 ML350 G5 servers they indicate the error is as in attachment, the servers are running well till now. is it necessary to change HDD's  P.S. This thread has been...

View Article

Replacing HD DL 320 G-6 Raid 1 setup

Have one bad HD on raid 1 setup . Have replacement drive both barracuda 250GB Sata drives but different part numbers.Will it work? Thanks

View Article


DL380 G4 - Trouble Shooting without opening up the server?

Hello all, I have a question regardin the DL380 G4 server. On the front of the system an Amber light came on. It reffered to the system health. After looking through the manual it mentioned that I...

View Article

ML150 G6 - New P410 controller not detecting SATA HD's during boot

IhaveaProliantML150G6, 4gbRAM, x2250GbSATAdrives, runningraidviasoftwareb110i, WIN2008SBS.(alldefaulth/wfromoriginalpurchase).  Serverrunsfineandbootswithnoissue, HD'sworkfine....

View Article


Proliant DL385 G5p and smart array controller P222

Hy, please i wanted an information: I have a Proliant DL 385 G5p and i have seen in hp website, controller P222 may be installed in Proliant GEN 8 and not in generation G5/G6 ETC... Why, If I have...

View Article

Expanding an array without data loss in an (old) ML350 G3 with a Smart Array...

I have an old ML350 G3 server with a Smart Array 5300 controller. I want to expand an array in RAID5 with one more disk (of same size of others in array), but ACU (boot from SmartStart CD) does not...

View Article


How to clear NVRAM on HP ML110 G4?

Hi! My HP ML110 G4 server has problems. After the BIOS updating System Board LED indicator CR7 is RED indicating an error has occurred.  Fans Spin, No Video on the screen. I excluded from it all...

View Article

DL320 G6 and VT-d - does anybody have this working?

I'm trying to get VT-d working with Linux and so far have been unsuccessful. I've enabled it in the BIOS and the machine boots fine until I pass the intel_iommu=on parameter to the kernel via grub....

View Article

NIC Teaming

So I have an older DL360 that we need to retire and are moving it to a new server. The new server has 4 nics that we will team together and the old server has two. we have about 1.8TB to move between...

View Article