problems after changing hard drive

$
0
0

hi forum

 

i have an problem with an hard drive in my server.

it is an ml350 g5 with an p400 controller.

there are two raids installed - on raid 1 an one raid5 with an spare disk

 

one of the disks in the raid5 (an GB0750C8047 with 750 gb) is broken so that the spare is used.

i bought now an 454146-B21BR with 1tb and replaced the drive.

 

now i get error messages:

 

cciss_vol_status /dev/cciss/c0d0

/dev/cciss/c0d0: (Smart Array P400) RAID 1 Volume 0 status: OK. 
/dev/cciss/c0d0: (Smart Array P400) RAID 5 Volume 1 status: OK.   At least one spare drive designated.  At least one activated on-line spare drive is completely rebuilt on this logical drive.  At least one spare drive activated.

  Failed drives:
         connector 1I box 1 bay 3                                                                    INQUIRY FAILED         

  Drives currently substituted for by spares:
         connector 2I box 1 bay 6                 ATA     GB0750C8047                          9QK19B3J             HPG6    

    Total of 1 failed physical drives detected on this logical drive.

 and

 

hpacucli

=> ctrl slot=4 pd 1I:1:3 show detail

Smart Array P400 in Slot 4

   array B

      physicaldrive 1I:1:3
         Port: 1I
         Box: 1
         Bay: 3
         Status: Failed
         Last Failure Reason: Not ready bad sense
         Drive Type: Data Drive
         Interface Type: SATA
         Size: 0 MB
         Serial Number: INQUIRY FAILED
         SATA NCQ Capable: False
         PHY Count: 1
         PHY Transfer Rate: 1.5Gbps

 

does it mean that the new drive isn't ok?

or is it my fault?

 

what can i do now?

 

thx