Hi All,
Recently updated RAID controller firmware version to 8.32 after a recent lockup of the RAID controller on a DL360pGen8 causing the server to freeze with the following message log in the hp IML log :
CRITICAL: Drive Array Subsystem - Drive Array Controller Failure (Slot 0)
But for some strange reason had another lockup on another DL360pGen8 server with the same critical errors shown in the IML logs post firmware update to 8.32 :
CRITICAL: Drive Array Subsystem - Drive Array Controller Failure (Slot 0)
The only indication of the fault is in the IML log shown above. Also, after conducting 2x reboots on the same server the machine came online successfully and since then can't see the fault/lockup/array controller failure happen again.
Can someone put me in the right direction to ascertain the reason behind the P420i array controller failure after updating to fw version 8.32 ? Are there any special logs I can retrive to get more info about the fault ? Is there anyway to simulate the fault again since it seems to be an intermittent fault ?
Thanks
csid2174