Hp ML110 G5

Hi, I have HP ML110 G5 Server & i attched 2x2TB HDD in Server But it's shown Only 1How i used Both HDD in Server insted of 1??? Thank YouBhaumik Patel

View Article


Proliant DL380 gen and VMWare VSAN compatibility

We are planning to use some Proliant DL380 Gen9 servers together with VMware VSAN but there aren't any SAS adapters from HP certified for VSAN. Does anybody knows when we can expect a certified SAS...

View Article


Proliant ML310e G8 boot error, boot logical drive is configured but missing...

Following a power outage the server will no longer boot up.  During bootup  I  get the following... HP Dyanamic Smart Array B120i RAID Controller (v3.06.0m 0MB) 0 Logical Volume1785-Drive Array Not...

View Article

P410 lockups on 256 SMART calls when firmware >= 5.70

Can anyone confirm some behavior we're seeing with the HP Smart Array P410 controller? Our disk monitoring system uses the SMART attributes provided by disks to provide us with early notification of...

View Article

DL380 & DL560 - How to change resolution settings

When interfacing with a FPM185 KMM  KVM, I receive 'out of range' messages .  How do I or were can I find the steps to modify the resolution settings on DL380/DL560 servers?  P.S. This thread has been...

View Article


hpsum doesn't install the root\hpq namespace

Hi all, On a server already joined in a domain i try to install the latest SPP using hpsum from the cli: ./hpsum /s /veryv /use_wmi /express_install However when i list all the namespaces i can't see...

View Article

Smart Array b110i can only detect 700GB of 3TB

Hi support, My server HP ML110G7 now has raid 1+0 (1TB x 2). Now i just want to add (3TB x 2) for storage only.. When i try to use the F8 in bios, it only allows me to create a logical drive of only...

View Article

RAID ADG enabler modules is missing or failed.

the setup:NetWare 6.5 SP8, HP DL380G5, with smart array e200i.3 disks are configured in raid5, now trying to add a 4th disk, using cpqonlin.nlm, which is the ACU for NetWare.When I start the tool, and...

View Article


HP Proliant DL160 Gen9 problem with drivers

Hello,I have got problems with two drivers for this server:1. Universal Seriall Bus ControllerPCI\VEN_8086&DEV_8D31&SUBSYS_8030103C&REV_052. Ethernet...

View Article


1.2TB SAS HDD temperature 60 C - OK? - DL380 Gen9

Hi, I've just setup a new DL380 Gen9 using 7 x 1.2TB, 2.5" SAS 10K drives.(HDDs Part No: 718162-B21, Manufactured Aug 2014)All drives have a current temperature above 55 °C, some have 60-61 °C, even...

View Article

P410i Array Controller ..Convert Raid 0 to Raid 1

We have a DL385 G7 Server with p410i Array controller.Have two drives ,during installation ,it took te default option of raid 0 and now we need to convert the array to raid 1.One disk showing...

View Article

HP Ethernet 10Gb 2-port 571FLR-SFP+ Adapter + Vmware ESXi Driver

Hi, I just bought HP Ethernet 10Gb 2-port 571FLR-SFP+ Adapter for my DL 380P G8 servers. There is no VMware 5.x driver for this card.  Only SLES and Redhat. normal / not normal ?  Do I have to change...

View Article

DL 560 G8 restart twice

One of our client bought DL 560 G8 (part number 686792-B21) He has  one P420I embedded smart array controller, 4 HP Disks ( Two HP 120 GB 2.5" Internal Solid State drive and two HP 300GB 6G SATA Value...

View Article


HP Ml350 g6 410i raid config with 8 600gb drives

Looking for some advice on configuring an ML350 G6 with the 410i on-board controller. The machine is being built with new SAS drives of 600GB capacity. We have 8 drives available (had 8 300GB drives...

View Article

Hot Spare Disk Replacement

I am having the following issue. I hope someone shed light on how to resolve this. We got a DL385 G7 box used as VMware ESX host and that was installed in the local LUN was configured with 5xdisk  RAID...

View Article


Image may be NSFW.
Clik here to view.

Smart Array P400 (HDD Drive upgrade)

Ive had the question of 'upgrading/replcement' options of an array, preff without having to fair RAID fallout. im planning to replace these 800's on SMART error notice with 1tb's from SeaGate.but can i...

View Article

p812 controller - JBOD mode?

Hello, Is there any way to put a p812 controller into JBOD mode? We want to use software RAID with a large number of disks. So far I haven't found a way to allow the OS to see indivudal drives that...

View Article


Intra-System Array Migration, p410i, p812

Here is what I would like to do: Move my OS Drive from a p410i controller to a p812 controller.Move one 35 disk drawer of my MDS 600 from a current existing p812 controller to a new p812 controller.I...

View Article

Disk Drive frimware?

Hi folks, This should be easy for someone. How do we find the disk drive firmware rev we are running on a Proliant DL380 G7? It's an ESXi box and I can't seem to locate it thru the ILO. Many thanks in...

View Article

HP Smart Array P400 controller

Hi,is HP Smart Array P400 controller an hot swap controller?How can I change my broken hard disk and re-align my RAID?Thank you.  P.S. This thread has been moevd from ProLiant Storage Systems to...