Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Browsing all 10362 articles
Browse latest View live

Proliant DL380 G - My Processor does not support Intel VT-x/EPT.

Came here to ask the experts. I a running an issue setting up nested ESXi inside ESXI server. My Processor does not support Intel VT-x/EPT. Is there anything I can do to tweak this, maybe with new...

View Article


DL360 G9 - SMH webpage and WBEM Providers - Physical Drives not visible

I have following problem: I have installed System Management Homepage and WBEM Providers to monitor my hardware on HP Proliant DL360 G9 (Windows Server 2012 R2) but in "Storage" tab there is no...

View Article


DL120G5 Bios update now fans running at full speed

HITrying to install Win2008R2 on a HP DL120G5. But ran into the embedded sata controller isue that won't allow Windows to detect my mirror array. And after several days of Googling I decided to update...

View Article

Proliant Drive Storage requirements help needed

Hi all, Can someone advise me on the components required to get 20 drives operational in a DL380G9 server. Spec I have identified at the moment: 1 x Proliant DL380 G9 Server (752689-B21)1 x Smart Array...

View Article

HP Proliant DL380 and DL580 G5 RAM Upgrade

Hi We want to upgrade our HP Proliant DL380 and DL580 G5 server memoy. I found 2 conflicting specs as below, http://h20564.www2.hp.com/hpsc/doc/public/display?docId=emr_na-c01673345...

View Article


DL380 G7 - Can't add second CPU

I have a DL380 G7 server with 1 E5620 processor.  When I try to add another E5620, when I power up the server, all the fans turns but the server won't boot. I have tried both CPU in socket 1 and they...

View Article

iLO 4 issues

In my Lastest batch of DL360 Gen8 sand DL380 Gen8 servers (order of about 40 systems), A little over 25% of them are having iLO issues.Wondering is anyone has seen any similar isues or has Ideas on...

View Article

Mixing different memory modules in DL 385 G7

Hi, I'd like to know if I can reuse the spare memory module from HP Proliant Blade (BL 465c G7) server into the HP Proliant DL 385 G7 server (573087 -371) ? Current Memory Module that is used on DL 385...

View Article


Getting email alert "A 'Host Health status change' Change in health status...

Folks, Can anyone here please suggest me what is happening with the server which sends multiple daily email like below: -----Original Message-----From: server1@domain.comSubject: Foundation Agents:...

View Article


SmartArray 410 reporting only 1.5GBPS

I have two DL180's with the exact same hardware specs but only one reports a speed of 3.0GBPS under hpacucli. The other reports 1.5BGBPS and the only discernible difference appears to be the port used...

View Article

SA-P800, ADU will not configured device : The cache is permanently disabled ?...

Hello We replaced a P400 card in a DL 320s G1 with a Smart Array P800 inorder to expand storage with a MSA 70. When I access the ACU utility  the following error appears : 351 Smart Array P800 in Slot...

View Article

How to remove a failed spare from an array?

Proliant ML350 G5, Smart Array E200i. A spare drive failed, and was replaced with another drive that turned out to be smaller than the original. The status of the physical drive is now as follows:...

View Article

Proliant ML350 G5 server keeps restarting randomly

Our Proliant ML350  G5 server keeps restarting randomly.Here is the Integrated Management Log entries from HP Diagnostics Tool: System Crash - Message: Windows bug check, STOP: 0x0000007F...

View Article


Create bootable HP USB Key for update RAID Controller Firmware

Hi, I have many new servers have problem with NMI error on Storage controller and require to install update firmware v1.34 (B)(11 Dec 2014) by offline update because my new servers did not have OS...

View Article

Prdictive Failure Drives

I have several drives on a server that are in Predictive Failure.Can I replace them 1 at a time?

View Article


m400 test system?

The m400 catridges contain ARMv8 processors meant for operation within a dense cluster of such in a Moonshot chassis.  My team is porting our data pipeline to run on the ARMv8 ISA and we'd like to get...

View Article

DL320 G6 enable Smart Array B110i SATA RAID Controller AFTER the OS is...

Hi,I have a server - DL320 G6 -with 2 hard drives.  Disk 0 is unallocated and Disk 1 has the OS (Windows Server 2008) AND it's been partitioned into two logical drives.  Looking at the server specs,...

View Article


Should I just give up on these DL165 G7 ilo100's?

I've inherited a farm of DL165 G7's, some have been waiting on their "ilo100" board installation since they were installed. As for the ones that have a ilo100 installed, the ilo100 seems totally...

View Article

ML350p Gen8 ticking noise

helloi purchased two ML350p Gen8 with 12Gb 15K sas disks ( yes the salesman fooled me and i didnt do a proper research ) , but i keep hear ticking every 5 minutes : tik tik tik tik tik tik .i did a...

View Article

Image may be NSFW.
Clik here to view.

Non-stop disk activity and Smart Array P222 controller in HP Proliant Gen 8...

Hi,We boughta server"HPProLiantDL320e Gen8 V2" with 2hard drives.We also boughta card"DynamicHP Smart ArrayP222Controler(512MB, v6.00) 1logicaldrive"to make thesedrives in RAID-1. We currently have...

View Article
Browsing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>