Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Browsing all 10362 articles
Browse latest View live

DL 360 GEN9 (This device cannot find enough free resources that it can use....

HELLO We are very dissapointed by this Server DL 360 GEN9. We have done all that is possible, all methods, all advices that were given by the HP technical solution consultant. The problem is not...

View Article


Proiant ML110 G3

Hi I have Proliant ML110 G3 serverWe install Windows server 2003, but two days later stopped workingI inside on the side of the motherboard light is red ledAnd the team no part, we leave with the...

View Article


upgrading HDs in RAID 1

Hi, New at this and would like to ask a few questions. - Using an HP DL360 G6- 2 drives of 300GB in a RAID 1- upgrading to new 1.2 TB drives as there is hardly any space left on the main OS partition....

View Article

ML350 G6 with 2 CPU Intel Xeon E5645 2.4GHz won't turn on with 2 CPU

Hi everyone, I am going crazy with this machine, here is what happen:The server has been working for over 5 years with the same memory and CPU, but one day after a shutdown, maintenance and then when I...

View Article

DL380 G5 boots to wrong time zone

Hello All, I have a dl380 G5 server that i have esx 5.5i installed and it keep booting to the wrong time zone even after i change it in the bios.  Anyone have any advice on what to check?  

View Article


HP DL380p G8 + MSA 2040

I am using DL380p G8 with one 4port 331FLR 1G NIC and one 2 port 530SFP+ 10G NIC, all of them are connecting to a MSA 2040 with iSCSI. When I try to create MPIO on the server, it works, unless I reboot...

View Article

Diags

Hi I have an old ML350 G3, no smart array controller fitted - just one drive (Ultra320 146GB) in a hot swap bay which is  connected directly to the embedded scsi controller. Insight states there's no...

View Article

Ml310E and LSI 9261-9i Issues

Good Day,i have so many problems with the LSI 9261-8i and Hp ML310E GEN 8 V2 server. I can enter the controller config but I cannot see any drives when trying to create a new config. I can see the...

View Article


New Drives failing in new DL385p Gen 8 server

Hi,I recieved a new DL385p GEN 8 server yesterday with 8 new disks.Loaded the disks and attempted to configure the RAID array (P420i controller) only to find 2 disks had failed. I swapped the disks...

View Article


Retasking DL380 G6 server - best way

I am retasking a number of DL380 G6 servers. The hardware configuration is appropriate. I will be installing Windows Server 2008 x64 on these units. Windows does not recogize the disk array out of the...

View Article

hp proliant ml310e gen8 v2 CentOS Installation Problem

hi when i try to install CentOs 7 i got this monitor problem.. any help?

View Article

Need "power on hours" stats for drives (DL380-G7)

 When I recently setup a new array on this server I used some tool that displayed the "power on hours" for all the installed (SFF) drives. I don't remember which tool I used but it was either embedded...

View Article

HP Proliant DL 360 Gen6 does not detect SSD

Hello, We have two servers HP Proliant DL 360 Gen6 with HP H221 Host Bus Adapter and HP D2700 Disk Enclosure connected to it. And the issue is that server does not detect SSDs installed to HP D2700....

View Article


SPP 2015?

Hi! I wonder there is no SPP in 2015 yet? When will the first one available? 

View Article

HP SUM Loading screen going round??

I cannot seem to run HP SUM (09.2014 version) on most of my servers - when it runs Inernet Explorer 10 it just states loading and the arrow thing goes round and round but does not proceed. I decided to...

View Article


ML350 G5 Power Supply - DPS-800GB A Schematic

Hi I'm repairing a power supply, part-number 379123-001, and have been looking for the schematic.Anyone knows where to get it from?I already emailed Delta Electronics and they told me to ask HP.  To...

View Article

Correct Cable for Ultra3 Performance

I am purchasing an ML370 and a Smart Array 5304 with 18.2GB Ultra3 Hot Plug 15K disk Drives. Does anyone know what correct cable to use to connect the array controller and the hard disks to achieve the...

View Article


RAID-5 WRONG CALCULATION BY SERVER

Hi, Im a new IT admin in my cimpany, and I have a server that already is configured with 8 SAS drives in RAID-5, but they have different sizes, let me tell you the server and storage details: HP...

View Article

Part number for connecting P212/256 with two disk 300Gb 6G SAS

Hi all, I have a ML110G6.I bought a new smart array controller (HP 462834-B21) and 2 disk (516824-B21) But I need SAS cable for connecting disk and controller.What câble I need (496013-B21+496012-B21)...

View Article

DS-KZPCC-UB

Hi all , I am new in town. I have a customer asking more information about an original replacement battery kit  shipped with a Manufacturing date code too old ( MFG code 59451= Nov 2009).He is saying...

View Article
Browsing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>