Problems with SAAP license
I have an unusual problem which I caused by offering to help a client upgrade a G7 system, a generation I'd skipped in my normal useage. For reasons passing understanding it is necessary to purchase...
View ArticleDL380 G5 memory setup?
Hi, I have an old hp dl380 g5 with 32gb ram (4x8GB 2Rx4 PC2 5300F 555 11 E0). I need more ram and i can get cheap 4x 4GB (2Rx4 PC 5300F 555 11 E0). Did the server support this setup? Best RegardsMaik
View ArticleMissing VID folder during RAID0 Windows install on Proliant Microserver Gen 8...
I was reinstalling windows and I wanted to make sure that I had a "clean BIOS" so I ran the reset BIOS in the BIOS and now when I get to the Windows installation screen no drives are detected to...
View ArticleIs ML10v2 with Pentium G3240 CPU official compatible with vSphere 5.5 (HP...
Hello Sorry for Offtopic but i have a question about the Ml10 v2. Maybe you can help me. Is the ML10v2 with the Pentium G3240 CPU official compatible with vSphere 5.5 (HP Vsphere Image) ?...
View Article2nd top backplane shows fault for all drives connected to it - DL360 G6
We recently added a second 4 bay backplane, spare part # 532147-001 to one of our DL360 G6 servers and for some reason when checking in iLO, all 4 drives are showing as Fault under drive status (See...
View Article"iLO: Undefined" - what do I need to change to put something in here please?
When I use the Integrated Remote Console I get the window header saying Server (name OK) | iLo: undefined. Where do I need to fill in something please to remove the "undefined" label (my tidy mind!)...
View Articlep410i smart array: cache disabled; wrong cache board attached
Hello, we recently installed a 1GB bbwc on a p410i smart array, dl 385 G7. upon restarting the server we saw the following error in iLO: POST error: 1795 - slot X drive array - cache module...
View ArticleML150 G9 and WS2012 R2 Foundation Edition
Hello, can I install Windows Server 2012 R2 Foundation Edition on HP ML150 G9?
View ArticleDirect Install Win Server 2008 r2 on dl30 G9
Is that possible to install windows sever 2008 r2 manual without use provision?
View Articleserver's shut down
Helo I needto prove that might be a problem for servers when they shut downin an abnormalway, forexample,fault current.I've donesome research on the net,but I did not finda credibledocument showing...
View ArticleDL120G6 won't boot with PCIe->SATA card & connected drive
Hi,I've got an DL120 G6 machine with 4xHDD connected to the mobo controller in a RAID10.I am trying to add an SSD to be used as a cache space for an app server.The mobo does not support more than 4x...
View ArticleHP Proliant DL380 G4 Server Firmware Update
We have an HP Proliant DL380 G4 Server that needs a firmware update on its Smart Array 6i storage controller. Following the documentation, I've downloaded the firmware update file cp009357, but it does...
View ArticleMicroserver Gen8 celeron. Halt at POST message 0114
I have just purchased a microserver and I thought I would be nice to it and upgrade the 2gb ram to 16. I have purchased a 2x8gb kit of Kingston 2400mhz non ecc ram, in case they didn't work it's the...
View ArticleML350 G5 Won't Boot with 2 CPUS
I have never heard of this issue before, so I am thinking maybe it is specific to this rig. I have tried several matching CPUs, and the rig won't boot. It boots fine with a single processor. So I know...
View ArticleDl380G9 - Fan issue
Hello, got some troubles with the Fans of our DL380G9.The fan speedvariesquite strongwhich is reflectedinpermanentvolumechanges.HP Support blames not supported HGST 8TB HE Drives for this behaviour -...
View ArticleHow to check if hardware RAID is configured
Hello Everybody,I have Server HP DL380 G5,I used HP smart start to configure RAID 1 and RAID 5 and Loaded Windows Server 2008 R2 Retail Disk on to RAID 1..This is my questions:1-When Windows COmpleted...
View ArticleAdding 534562-B21 HP 1G Flash Backed Cache to ML350 G6, no drives seen
Hello! I have an ML350 G6 with an embedded P410i ZM array controller. I have one array of two 450GB 15K SAS drives. When I bought it, Ingram Micro's HP support told me that cache is not needed for a...
View ArticleProblem with HP DL380G5. Please help
Hello, I am having an issue with HP DL380G5 server which has WINDOWS 2008 system installed on it.The system restarts occasionally and I could not find any serious error messages in Windows system logs...
View Articlehp proliant ml10v2 + server 2008r2 sp1
Product Name: hp proliant ml10 v2Operating System: Microsoft Windows Server 2008 r2 enterprice (64-bit)sorry for my english.new hp proliant ml10 v2. raid 1 was configurate (using hp util) and enable in...
View ArticleDL 360 GEN9
Collectedthe server (1processor,6 cores), installed Windowsserver 2008R2. There were problems, if you shut down the serveran error occurs.If you restart the server, all is well.All driversare up to date!
View Article