Rack depth needed for an ML350e G8 ?
Hi, I'm trying to find out the minimum distance (depth) between the front and rear posts of a cabinet, in order to rackmount an ML350e G8. I know the server is 740mm deep (29 1/8") and that the part...
View Article1797-Slot 0 Drive Array - Array Accelerator Read Error Occured
Slot 0 HP Smart Array P400 Controller (256MB, v7.8) 1 logical drive1797-Slot 0 Drive Array - Array Accelerator Read Error Occured Array Accelerator is disabledSlot 0 HP Smart Array P400 Controller...
View ArticleError 24606
Customer keep getting Source: Cissesrv Event ID:24606 after replacing a bad Harddrive for past month. Event log has Logical drive 1 of array controller P410i [Embedded] returned a fatal error during a...
View ArticleDual power supplies, dual voltage
I have a DL360p with dual power supplies. What would happen if I plugged one of the power supplies into a 220V outlet and the other into 110V? I'm thinking it'd be fine, assuming the power switching...
View ArticleProliant DL380e Gen8 Uncorrectable Machine Check Exception
Hello, I'm currently having a hard time troubleshooting the root cause of a random and frequent reboot on a Proliant DL380e Gen8 server. The errors given by the Integrated Management Log are the...
View ArticleML115 has died
Our Proliant ML115 has been running well for a few years. Today it suddenly died. At one stage there was a message on the screen about 'BMC not responding', but now it doesn't even get as far as the...
View ArticleHP SUM 6.0.1 issue upgrading System ROM : Node up to date. No applicable...
Hi,I'm trying to use HP SUM 6.0.1 to deploy a System ROM update on a ProLiant DL380 G6 server. It's an ESXi server running VSphere 5.1. I want to upgrade the server BIOS from version P62 2011.05.05 to...
View ArticleProliant ML350 Gen6 with P410i controller - cannot migrate to RAID 1+0
Hello! Recently our storage (and AD) server was planned for RAID migration on storage volume for better performance benefits. In past it was running 8 SATA drives (each 1TB) in RAID 5+0 configuration,...
View ArticleHow to replace RAID Drive
I have an old Proliant DL380 (I think G1) running Windows Server 2003. I've got four SCSI drives in a RAID 5 config. I think I need to replace one of the drives (ID 3). When I run the HP Array...
View ArticleRIBCL syntax for Storage information of Gen8 server
Hi, I am confused about using RIBCL to get server information. When I use iLO 4 web interface (firmware version 1.30), I can get Storage Information (section Server information) with two types of view:...
View ArticleSplit mirror without removing either hard drive
I have a ML350 G6 server that i would like to split the array on for recovery purposes (Planning risky upgrade). The server has a single RAID 1 mirror and the integrated 410i controller. I have no...
View ArticleMax hard drive sizes for ML350 G3 server with Smart Array 641 controller?
Hello, I have inherited a spare ML350 G3 server which seems to be about 10 years old. It is a tower case with 6 hot-swap bays and the Smart Array 641 controller. I am interested in possibly using this...
View ArticleHP DL120 G6 - AHCI Windows 2003 std 64bit install
Hi, Having a bit of trouble with a DL120 G6, Windows 2003 and AHCI. When I enable it in the BIOS the windows setup failed with a BSOD (0x0000007B). I have tried lots of different drivers to get it...
View ArticleHow to know all the related MIBs of HP DL380 Gen8
I want to do the fault management with Gen8. Is there any document describng this?
View Articlereplace drive in raid 5 in dl380 g7
Hello,I've got a dl380 g7 and one of the drives is flashing amber but also flashing green. It means that the drive is still working but will fail soon. I have 6 drives in this raid with one spare. My...
View ArticleDL 180 G6 update firmware controller P410
good morning to all,Should I upgrade the firmware of the controller (P410 on DL 180 G6).The installed version is 3:52, the latest version available is 6:40 SBS 2003 operating system is 32-bit.Can I...
View ArticleProLiant ML350 G6
Hi all, I have just run the support pack psp-9.10.w2k8.i386 against one of our test servers. This server has 5 SAS disks installed on the internal P410i raid controller. 2 disks are in a mirror and 3...
View ArticleDL350 Intelligent provisioning is looking for Optical or ILo media...
Have a brand new HP DL350. I am trying to do the IP using the F10 key. When i get in and start selecting the OS etc, i get a message that says "please insert optical or ILO media before proceeding"....
View ArticleESATA Card Supported (ProLiant DL380 G7)
Looking for a add in card to be able plug into the PCI risers. I tried two and both didnt work properly.. Anyone have a fairly inexpensive card? Machine again is a "ProLiant DL380 G7" Thank you
View ArticleHP Proliant DL360p Gen8 Memory Speed
Dear all, we have a new DL360p Gen8 sever with 1 x Intel(R) Xeon(R) CPU E5-2660 v2 @ 2.20GHz.The server is populated with 12 x 16GB RDIMM 1866Mhz. Memory configuration is attached. The memory however...
View Article