booting issue (possible overheating?)

I have a rack of servers and they are all on battery backup. Over the weekend we had a bunch of storms and the power went out. Our battery backups keep them online for roughly 2 or so hours. Our A/C...

View Article


error LEDs HP Proliant ML370 G4

when I turn onthe server, notall LEDslight up. attach Image

View Article


ML350 G5 server - Smart Array E200i Firmware Update

Hello, I have an issue reported through iLO2 IML for a ML350 G5 Server: 1794-Drive Array - Array Accelerator Battery Charge Low. The current version of the Smart Array Controller is 1.80. The server...

View Article

HP SPP 2/14 Hanging while loading

Hi all, I just downloaded and burned the February 2014 Service Pack for ProLiant, and upon attemtping to run it in a DL380G5 system (which would run the one from 9/13 just fine), it gets to the loading...

View Article

Re: few questions about ProLiant DL360 G7

Hi. first must say thx for help post.I got only one processor installed, and I add RAM where be original when I got server in my hand's like on attached picture, I think is some issue on motherboard or...

View Article


Advice for avoiding configuration errors when swapping System Board on an...

Hi, Just a few months before retirement, a ML370 G3 has developed the redundant fan issue and periodically shuts down due to fan #3 failing (even though the fan has been swapped / is known to be good)....

View Article

HP ProLiant ML370 G4

I need manual/diagram to motherboard at HP PrioLiant ML370 G4, I need to know the function for each LEDs. attach image. thanks

View Article

Proliant ML370 => Fan problem

Hi, I've a ML370 with a fan Problem. This server refuse to boot saying that there is not enought redundant fan solution. I've 6 hot-swapable fan in it, and only three of them are spinning. They are...

View Article


ML370 G3 Redundant Fan Failure

Getting a 1611 error on this server. Fans 2,3,4 show as failed. Replaced fan with known good (one from slot 5) and still fails. Anyone seen this before? This server's only about 18 months old and has...

View Article


P420 configuration performance

Hi  all, I have a question concerning what will best for a rais 5 array utilisation on windows 2012: is it better, for a performance point of view, to create a single logical drive and create 2 windows...

View Article

Smart Array 410i logical drive extended but size not updated in RedHat

I've added 2 disks to the Smart Array 410i and extended the logical drive, but I am unable to rescan thecciss driver to update the drive size in the OS.  I've tried a reboot and that doesn't work...

View Article

SPP 2014.02 + DL385 G7 + Win2008 R2 SP1 U1 = bad news

Folks, Is there some known flakiness in the combination of SPP 2014.02 + DL385 G7 + Win2008 R2 SP1 U1?  I've tried this install on two different servers and both have done the same thing: go into a...

View Article

HP ML350e and installing Oracle Linux 6.5

Trying to install Oracle Linux 6.5 and get Kernel Panic when it boots. Can I install on this server oracle linux? If yes, what should be done that would not get errors?  Thanks!

View Article


serious issues with HP ProLiant DL

I've been recently tasked the wonderful "luxury" of managing a Windows 2003r2 Standard server running on an HP ProLiant DL. I don't have the exact model or generation at the moment, but I'll add that...

View Article

updates for the HP ProLiant DL360 G5

is there an easy way to verify and update if necessary all the updates for the HP ProLiant DL360 G5? from what I've discovered, you need access to Version Control Repository Manager, but I don't see...

View Article


serious issues with HP ProLiant DL 380 G5

I've been recently tasked the wonderful "luxury" of managing a Windows 2003r2 Standard server running on an HP ProLiant DL. I don't have the exact model or generation at the moment, but I'll add that...

View Article

Problem in DL580 G7

Hi i use 3host with 512 GB ram in DL580 with X cluster in Vsphere 5.5 u1 last moth i have standlone host for mangeing my eva 6000 .my eva must b user HBA for mangeing the Vdisk ,I use standlone host...

View Article


2x300GB SFF HP not showing in my computers

Dear Friends .. i have newly installed HP ProLiant DL380p Gen8 E5-2609 P420i/512MB FBWC 4x1Gb Flex 1x8GB(L) 2x300GB SFF HP DVD-RW 1x460W and installed microsoft windows server 2008 r2 standard edition...

View Article

HP Proliant DL180 G6 with ESXi 5.0.0 - Continuous I/O error

Hi There, Previously, I've posted an issue which I was facing with the server in detail as I am a newbie to Proliant servers. It's on a P410 smart array with RAID 6 (two disk fault tolerance - 1TB x...

View Article

Hpsa problems

Hello, My system worked perfectly for fews months but since 1-2 weeks I have a big issue. Sometimes, in /var/log/messages I got messages like that : hpsa 0000:04:00.0: Abort request on C0:B0:T0:L0hpsa...

View Article