Im having a similar issue on a brand new out of the box, HP DL380 Gen9, whereby the Array B140i shows up as working, but when i try and run the configuration, it keeps telling me there are no physical disks present, but ive 8 of them installed in the system.
No disk drives detected on DL380 G9 with B140i
e200i on Raid 5 logical drive Parity Initialization Status at 0%
Hi there,
I have a HP ML350 G5 where we have replaced a failing HD in a Raid 5 array of 3 disks, the replacement drive has synchronised but in ACU it still shows a information alert for the Parity Initialization Status (currently at 0% and has been for the last 4 days since the drive was changed).
If I view the Information Status Messages I get a Code 785; Background parity initialization is currently queued or in progress on Logical Drive 1 (136.7 GB, RAID 5). If background parity initialization is queued, it will start when I/O is performed on the drive. When background parity initialization completes, the performance of the logical drive will improve.
I need to change another drive soon as it is displaying F155: The read/write hard error rate recorded in the monitor and performance log is above the acceptable threshold.
However I daren't change another drive until the parity sync is complete, does anyone have any thoughts as to futher actoin I should take?
Thanks in advance
Host bus adapter H222 and RAID for Prolian DL380e Gen8
Hello,
I have server DL380e Gen8 (P/N: 648255-421) with B120i RAID controller and H222 Host Bus Adapter with attached tape drive (LTO 5). Up to now I was using configuration with 4 LFF SATA drives. Now I've added 2 more LFF SATA drives but unfortunately I cannot find second cable for the backplane ( 2 port SATA cable 675856-B21) because is not available any more (which is extremely strange for server still in warranty)
If I connect the second port on the backplane with SAS cable to the internal port of the H22 Host Bus Adapter, will the RAID controller see the disk?
how to check ipv6 gw info from ilo4
hi,
I would like to check the Ipv6 address and Gw informatio via ilo4 console. we are using ILO FW- 1.51 Jun 16 2014
ther reason is we inable launch ilo via web so we need to check if there is any ipv6 isue as we are using ipv6 addres.
THanks
Proliant ML350 G5 E200i controller failed battery message cannot be remedied
I get the message below for the E200i controller on the system. Even though the battery voltage checked out, I bought a replacement, and the message stayed the same. So I got a brand new controller ... and the message STILL persists.
I've installed every updated driver for the system that's available, save for the BIOS update, which HP will not let you have without a service agreement. The drive controller is Intel 6300ESB Ultra ATA, and I have the latest drive
There are two connectors on the card that have never been connected to anything. Does something besides the bus connector have to be attached to the motherboard to report the battery power? Is there any difference between what the program reports for a weak battery and NO battery?
Stand alone remote console for Linux systems
Hello,
Is there a HP stand alone remote console for linux? Similar to HPLOCONS for windows http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f842ceb31cf48d392e22705a8?
I looking for a stand alone remote console that works in linux OS to connect to a 'ProliantDL380e Gen8' machine.
Thanks,
Aishwarya
get ahs logs using scripts
how to get ahs logs when there is no ilo GU access. we are using linux os in blade where we can loign normally.
Thanks
Nag
ML350p G8 P420i Additional Drive Cage
Hello,
I have an ML350p G8 Server with an LFF Drive Cage with 6 x 1TB SAS. But soon i need more Disk Space.
It's possible to add an second LFF Drive Cage to the P420i Controller?
Thanks for Help
ML330 G6
I bought a new External Tape LTO 3000 ultrium but my SAS controoler (P410 if i recall correct) dont have Externarl Port.
I search for P212 but seem to be in "no sold anymore" state.
My question is: can i use H222 HOST BUS ADAPTER or a P222 on my server (both is raccomanded for G8 servers)
In teory exist a cable that permit use internal SFF8087 using a pci "slot". I cant figure out if is AE464A or AG452A. In both case seem to easy to find a H222 controller.
Thanks
System currently defaulted to typical configuration settings ?
Hi,
I've got Proliant DL 360 G7 which is behaving erratically, it always lose the iLO configuration (IP address kept on changing by DHCP) and everytime I reboot the server it always taking so long time to show the POST screen, because it must go to the memory diagnostic screen.
I also see there is a glimpse of error during the reboot mentioning about
System currently defaulted to typical configuration settings
Somehow the OS running is not affected by this, I wonder what could be the cause and the solution to this issue ?
p212 controller allows only two logical drive creation? Wht is the solution for more?
Hello,
Currently my zero memory p212 card, can only create two logical array. If I buy, 256 MB memory board, can I add two more disk and create four arrays?
ML350Gen9 IP2.30.275 server2012r2 "Windows: not supported"
Hi Everyone,
Every search I have made on this has no reference to the above error or relates to other issues entirely.
Have taken dleviery of new ML350gen9, and in trying to install Server2012r2 Eval iso ( have tried 3 different ISO's at this stage) from Technet, Intelligent Provisioning will not accept them displaying "Windows: not supported" after selecting the source device and "continue".
We have tried:
- ISO from USB.
- "Rufus" install formatted as both FAT and NTFS
- ISO from WIN network share
unfortunately do not haved a DVD drive to use
IP version is 2.30.275, maintenance firmware check shows latest available from HP is 2.30 (so would be a downgrade if reflashed) and all firmwares are latest.
latest ISO tested is: 9600.17050.WINBLUE_REFRESH.140317-1640_X64FRE_SERVER_EVAL_EN-US-IR3_SSS_X64FREE_EN-US_DV9
Has anyone come across this before?
Thanks,
Chris.
Dl380 Gen9 Won't boot after reboot. - It was just fine before!
Hello
I have a DL390 Gen9 that after a reboot, it wont boot into windows. I have an OCZ Revo Drive and 6 - 2.5" SAS drives in a RAID5 with a hot spare. The OS is on the Revo Drive with Windows 2012 R2 and the data is on the RAID. Originally the OS and data were both on the RAID, but once the server rebooted the OS would not come back up. I tried fixing the mbr, tried repairing windows, and nothing worked. I ended up reinstalling windows. It booted up and life was great, but once it rebooted agian, the same issue occured. Just incase, I installed the OS on the revo drive. I did not reboot afterwards, but they had a scheduled power outage in that office and now that the server rebooted it wont come up again.
I have tried both UEFI and Legacy BIOS mode, tried wiping the RAID, and recreating it, and there are no USB drives or what not plugged into it.
Also, the RAID is set as GPT with 1TB drives, but this is only data now, the OS is on the Revo Drive which is 250GB.
Do yall have any ideas of what could make it not boot into the OS?
Xeon E5 1650v3 with ML150
Hi,
Can i swap my 2609v3 for a 1650v3 if i don't want to use dual CPUs?
Does ML150 support that CPU and can i use the passive heatstick that are mounted on 2609v3?
DL380G9 10-Gb-533FLR-T iscsi Esxi6 iscsi tcp offload aka hardware dependend iscsi
Hi
I have installed a new dl380Gen9 with a HP FlexFabric 10GB 533FLR-T Adapter onboard.
I Used the HP Customized ESXi Build and updated the Server with the last SPP from Oktober.
After the sucessfully install i tryed to use the Hardware dependend iscsi. But i cant see the vmhba under storage in the vsphere client. There is only the SATA controller and the Smartarry but no Brodcom.
I tryed to open a case at hp but i dont get no responde till jet.
I downloaded to be shure the newest firmware and also drivers from the hpe support page for the nic but if i try to upgrade or install im getting the notice that already have the latest driver installed.
I Read the article about iscsi Offlload
The Site 24 under VMware discripes how to configure but well i still cant see the vmhba.3x.
Has anyone the same problem or have any idea how to fix it?
I dont want use the software iscsi cause of the load witch we ar generating over the 10GB nic....
Thanks
Florian
Proliant DL360 gen9 Post code 711 stale during BIOS
Can't boot server. Stop on Post Code 711.
There are two D3000 (x12x6TB SATA) shelves connected to the server.
SAS Cable for ML150 G9
Hi,
Is the cable 729106-001 for use with Two 4-LFF cages but only using one 8087 SAS Port?
ML110G7 and B110i controller
After a crash of our backup server which is a ML110G7 with integrated B110 array controller attached to 2 x SATA 160 GB drives in RAID level 1, we are unable to boot from disk running W2K8R2. So we tried to do a new OS setup, but failed when installing it to disks. OS doesn't see devices, whereas a Linux boot with G-PARTED shows the disks as expected.
We tried to integrate device drivers from website via iLO mounted iso device during installation but it fails. Is it possible controller is damaged allthough option rom shows the disks and recognizes raid and logical drive?
Regards, Klaus
HP QLogic NX2 10/20GbE Multifunction Drivers fails during SPP installation
Hello,
The Installation with SPP 2015.10 fails with package cp025087.exe (HP QLogic NX2 10/20GbE Multifunction Drivers for Windows Server x64 Editions 7.12.41.0 1 Okt 2015) on a Proliant DL385 G7 Server with Windows 2012 R2.
Erromessage in HPSum log is a fault during HP Virtual Bus Device installation. Could someone support me to solve this issue?
regards,
porliant Dl360 G9 how to make partition throw intelligent provisioning
Hello,
we have HP server G9 DL360, i installed windows server 2008 R2 through intelligent provisioning
but did not allow me to select partition drive like (C: and D:)
please help me to slove this matter.
second thing when changing bios form UEFI mode to Lagecy mode the windows does not working.
thanks