HP Smart Array P440 Controller operating temperature

$
0
0

Wondering if 85C would be considered a normal operating temperature for P440 controller? 
Thanks

fans.png


ML350p Gen8 Noise

$
0
0
My ML350p Gen8 has been making disturbing noise in a strange pattern. Two of the three fans installed are spinning in a pattern like this
6% for a few secs→goes up to more than 20%→goes down to 6%→goes up and repeat.
The other one sticks to 6%.
I am really annoyed by the noise, and I have to put the device in my own bedroom.
Actually I don't mind if all the fans are spinning at a constant 20%, which has a bearable loudness, but the process of fans spinning up makes a disturbing siren-like noise.
I just disabled PCIe 3.0 support for the integrated P420i controller, the pattern continues, but the fans goes up to about 15%, much better.
Here's my system configuration.
1*E5-2670 stepping C1
4*DDR3 ECC Reg 4GB 1333MHz RAM by Kingston
1*500GB Seagate Pipeline (controller Channel A Port 1)
1*2TB Seagate Desktop (controller Channel B Port 1)
No PCI express devices attached
OS is Server 2012 R2
All firmwares are up to date with Intelligent Provisioning the exception, which is version 1.62 instead of 1.62b.
Any ideas on how to completely solve this problem?
BTW the fans spinning up are fan 3 and fan 4, which are at the lower half of the device, where the P420i controller is located. I guess this strange pattern has something to do with P420i, wonder if I can put an LSI HBA on the device and disable P420i.

HP Proliant DL180 G6 LO-100 PW Reset/Enable Usernames through IPMIUTIL

$
0
0

Hey guys,


I bought a used server and it looks like all but one of the user accounts are disabled according to IPMIUTIL. I was wondering if anyone would know a way to enable the other users through this tool or if someone had a good explanation of how to do it through IPMITool. Although I would prefer IPMIUTIL.

ILO 4 CLI References

$
0
0

Hi,

I want to configure a HP Proliant Gen 8 BL660 ILO 4 From the commands Line, so i need a CLI references to do it,

please help me.

 

Thanks 

10Gb 2-port 561FLR-T slow copy speed

$
0
0

We have purchased a couple off 10Gb 2-port 561FLR-T put them I DL380 GEN8 servers and one HPE 5900AF-48XGT (10 GB switch). The cables are CAT 6 max length 2 M.

 

We have tried almost every settings, 10 GB full duplex on nic and switch. Testing different settings enable, disable Virtual machine ques, increase/de crease checksum, buffers and ………

 

Whatever we do the file copying never passes 300 MB/s .

What settings should I have on the NIC to get most throughput?

 

HP Smart Array B110i 32 Bit Raid Drivers Needed

$
0
0

 Hi,

 

I am stucked in situation where i am unable to restore my machine with Symantec Backup Recovery, As the SRD (Symatec Recovery DISK) is based on 32 Bit os i cannot load Smart Array B110i 64 Bit Drivers which is available on hp site. But i am unable to find 32 Bit Driver for Smart Array B110i. So i cannot see the target drive in SRD Enviroment. As no drivers are available for RAID Card. Please do needful.

 

Please help. I am unable to find way out for this.

total memory - ecc test failed

$
0
0

I have an ML 350 G5 with the above error message in insight diagnostic offline diagnostic test

Is this a dimm error ? If yes how can i find which dimm is ?

HDD not regognized as HP Genuine

$
0
0

Hello,

we have a problem with a HP DL380p G8 Server showing a replaced HDD yellow because ist is not authenticated.

We have installed the latest firmware & drivers for the array controller P420i, but the drive is alway reported as degraded and showed "Authentication Failed".

in SMH, if you choose WBEM as datasource, the drive is reportet green, but if you choose SNMP as datasource the drive is reported yellow. See screenshots.

What the heck is going on there? Any suggestions?


Power Supply - What is maximum operating temperature ?

Adding hard drive in exisiting array

$
0
0

I have a server hp Proliant DL380P G8

installed windows 2012r2  standard edition

server it has smart array p420i

I have configured RAID 5 array with three hard drives 600GB SAS

recently i added one more drive with same capacity   it's showing all the drives in Array

but in disk management tool it's not showing anything let me know please what would the problem

would be appreciate your quick response

 

 

 

DL380 G5 CPU upgrade from dual core to quad core not working

$
0
0

I currently have a single Xeon dual core 5130 in my system (DL380 G5).  I also have the board supporting up to the quad core 5430's (436526-001).  I have attempted multiple 5430's and VRM's out of working systems, but none will boot.  The fans run at high RPM, and no video is present.  iLO still functions.  Replacing with the 5130 again, it boots fine.  

Steps taken:

I have completed a full ROM upgrade using the HPE SPP from 2016.

I have attempted one 5430 and VRM at a time, or both.  I have attempted 4x VRM's (known working) and 3x 5430's.

I have reset NVRAM and iLO.

 

Any ideas?  I would be able to bump up this system from a single dual core 2.0ghz proc to 2x quad core 2.6ghz procs, which would be a HUGE performance jump.

HP DL360 G6 Error hard disk after replace the hard disk fail

$
0
0

We have the HP DL360 G6 server.

When we checking the system and see the erros with hard disk.

[root@DAN1-IMF-1B ~]# syscheck
Running modules in class hardware...
OK

Running modules in class net...
OK

Running modules in class disk...
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: Health, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_00], SMART Failure: HARDWARE IMPENDING FAILURE GENERAL HARD DRIVE FAILURE. Physical disk: 1I:1:1, Controller Slot: 0, Serial number: 6SE1T3YJ0000B119M5SC., First occurred: Tue Aug 4 19:37:37 2015 ICT.
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: FailedReadSmartSelfTestLog, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_01], Read SMART Self-Test Log Failed. Physical disk: 1I:1:2, Controller Slot: 0, Serial number: 6SE2H8BP0000B130JKE6., First occurred: Sat Sep 19 06:37:38 2015 ICT.
* smart: FAILURE:: MINOR::5000000000000800 -- Server Disk Self Test Warning
* smart: FAILURE:: Failure type: FailedReadSmartData, Failure message: Device: /dev/cciss/c0d0 [cciss_disk_01], failed to read SMART values. Physical disk: 1I:1:2, Controller Slot: 0, Serial number: 6SE2H8BP0000B130JKE6., First occurred: Sat Sep 19 06:37:38 2015 ICT.
* hpdisk: FAILURE:: MAJOR::3000000080000000 -- HP Disks need intervention.
* hpdisk: FAILURE:: Failure message: logicaldrive 1 for controller in slot 0 is Interim Recovery Mode.
* hpdisk: FAILURE:: MAJOR::3000000080000000 -- HP Disks need intervention.
* hpdisk: FAILURE:: Failure message: physicaldrive 1I:1:1 for controller in slot 0 is Failed.
One or more module in class "disk" FAILED

Running modules in class proc...
OK

Running modules in class system...
OK

LOG LOCATION: /var/TKLC/log/syscheck/fail_log
[root@DAN1-IMF-1B ~]# hpacucli ctrl all show config

Smart Array P410i in Slot 0 (Embedded) (sn: 5001438010368F90)

array A (SAS, Unused Space: 0 MB)


logicaldrive 1 (279.4 GB, RAID 1, Interim Recovery Mode)

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, Failed)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)

SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438010368F9F)

[root@DAN1-IMF-1B ~]# hpacucli ctrl all show detail

Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 5001438010368F90
Cache Serial Number: PAAVPID1046103G
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 3.52
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 400 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True

We replace the failed hard disk with a new hp hard disk. And then the error was be clear. But, after few days.  We checking again. The hard disk error again, and we replaced continues with a new hard disk. But it been same! The hard disk to be error

Hope anyone here can provide some advice. If you need further information. Do let me know.

Thank you in advance.

 

Changing the existing Logical Drive Stripe Size and RAID type one by one ?

$
0
0

Hi All,

My predecessor has made some mistake in the planning and the deployment of the large backup server which has caused the backup process to runs very slow.

So now my goal here is to reconfigure everything to the Veeam Backup Best practice. But I can only allowed to do it manually partition by partitionnot destroying the whole production backup.

  1. How can I change the existing Logical Drives RAID type from RAID50 and RAID6 into just RAID 5 ?
  2. Regarding the Stripe / Full Strip Size, how can I change it to use the largest value possible ?

Migrate.JPG

Note: I'm running on Windows Server 2008 R2.

Any help and suggestion would be greatly appreciated.

Thanks

ML350 G5 mix and match options

$
0
0

Greetings all,

Hope this finds you well.

So, we were recently 'gifted' some ML350 servers from an offsite location.  I currently have all Dell gear in my shop and have no hands-on with HPE gear so, here I am looking to you.  :)

I have 4 ML350 servers, 1 G4 and 3 G5.  What I want to do is make one decent machine out of it..

I'm focusing on the 3 G5 boxes at this point as they are all identicle: 2GB RAM, Xeon 5130 (single proc), and 8 bay, 2.5" HDD cage.

I want to pull all the RAM into one box, double up on the CPU, and double up on hte HDD cage.  

My questions: what do I need hardware/software wise in order to do this?  I know I need a PMM to load up the 2nd processor but can I actually use a second HDD cage and 8 more drives natively?  Can I pull the RAID expansion card from the G4 (HP SMART ARRAY 642 CONTROLLER (012591-000) in the G5 to accomodate the second cage?

A lot of questions, but I'm trying to work with what I have as money is non-existent. (At least according to the folks that make way more that me...)

Thanks everyone.

Cheers,
MC

HP ProLiant DL180 G5 - NOISE

$
0
0

 While the HP ProLiant DL180 G5 server running cooler is very loud . BIOS version O19 from 10 / 25/2010. SN:CZC8377290

OS: Microsoft Windows Server 2008 Standard 32-bit SP2. temperature mode is normal.

I read similar topics. there said that the problem in updating your BIOS, but I was already the latest version

Help solve the noise problem! Smiley Sad


esata card for HP ML350P Gen8

$
0
0

I need a hot pluggable esata interface on a HP ML350P server running Windows 2008 R2 server. I have tried using the Startech PEXESATA2, which I have used succesfully on a HP DL380P Gen8, but this is not detected on the ML350P (does not appear in device manager). On Startech advice have tried the PEXESAT32, but the server crashes to a blue screen with the message NMI:Channel Check/IOCHECK. Has anyone succesfully got an eSATA card working on this server, and if so what type?

Smartarray p400 reporting predictive drive failure even after replacing drive

$
0
0

We have a server with a P400 controller in a raid 5 configuration. We replaced a drive because of predictive drive failure warnings. But soon after replacing with a new drive we have the same warning messages for the new drive. Could this be a false alarm?

HP ML350 G5

Raid 5 configuration 3x146 SAS

Thank you.

Problèmes durant l'installation ML370 G5

$
0
0

I No devices found to install Red Hat Enterprise Linux in the RED-HAT 3.0 installation
???? can help me PLEASE ????

no driver found redhat install

$
0
0

hello

i have this problme ''' no driver found redhat install 3.0''''

can help me ????

Unrecoverable system error (NMI) 0x7FBCE8F6

$
0
0

 

I got  this error from our new server DL380 Gen9.  Any idea how to fix this?

 