Issue with HP FlexFabric 10Gb 2port 534FLR-SFP

$
0
0

Hello,

does anyone have issue with  FlexFabric 10Gb 2port 534FLR-SFP on Ubuntu 18.04?

My setup is - two interfaces in lacp bond and mtu 6000 .

The problem is that my servers are crashing with:

An Unrecoverable System Error (NMI) has occurred (Service Information: 0x00000000, 0xE0FF0000)
ASR Detected by System ROM

PCI Bus Error (Slot 0, Bus 0, Device 2, Function 2)

That is happening on three servers (DL380 Gen9) with similar hardware/firmware/settings.

They are with the latest SP and unfortunately,  warranty has expired.


HP DL380pG8 E5-2609 Latest Drivers and Bios Utility

$
0
0

Hi All,

 

I am looking for "HP DL380pG8 E5-2609" server's utilities to check Windows Server 2012 r2 drivers updates and Bios updates.

The server is out of warranty and has no contract support with HPE.

Thanks in well Adv.

Best Regards

Faisal

B140i RAID5 write @ 80 MBs read @ 500 MBs

$
0
0

Just wanted to ask what peoples experience are with these base model ML30G9 with a B140i embedded controller using 4x MB001000GWFWK 1TB SATA drives in RAID5?

  • I have enabled/disabled write cache and it does not make any difference
  • I have enabled/disabled controller caching - no difference
  • Tried different drivers 62.6.0.64, 62.8.0.64 and 62.12.0.64

According to ATTO, the highest write is 80 MB/s (Megabytes p/s)  from 4MB although read is fantastic at 450 MBs+ at 4KB.

Any help would be much apprecaited.

I have logged a case and was advised it was write cache and waiting for further reply.

HP ML150 Gen9 SSD on sata port on Motherboard

$
0
0

Hi,

I have a new HP ML150 Gen9 Tower, with dual 1TB SATA connected to the b140 storage controller. Using them in raid 0. Windows 2016 installed and everything runs perfect.

Now i decided to connect a loose SSD harddrive to a free sata connecter on the motherboard. The problem is that windows does not recognize the disk at all. Not te be found in device manager or anywhere else.

If i temporarily switch the bios from UEFI to Legacy i can see the drive in de boot options screen. So the drive seems te be properly recognized by the server. I also tested the ssd in a client pc and it works properly.

Can anyone give me advise in this matter?

Thx!

Dave

system management homepage no items impossible d'installer HPE Insight Management WBEM Providers

$
0
0

la page affiche "no items" pour regler le probleme il indique d'installer les elemment suivant :

HPE Insight Management WBEM Providers and/or HPE Insight management Agents

mais il est impossible de les installer, je suis sous windows serve 2016

DL380 Gen 10 SAS HDD installation

$
0
0

Hello I have a DL380 Gen10 Server and I installed 2 SAS 10K HDD P/N 872477-B21. With intelligent provisioning the system can not see any disk do I have to set up anything to make them visible, the SR100S is enabled, the disks lights up but the system tells me that no disks are installed....any suggestions?

The P/N on the HPE box is 872477-B21 but on the HDD is written another P/N 876938-001

Raid hard disks don't blink!

$
0
0

I have a server hp proliant dl180 g6, the raid keeps drops every few hours, i find the leds of all disks turned off.

Replace disks in a RAID 1

$
0
0

Hello good afternoon.

I currently have a HPE ML110 G9 server with a 4GB p440 controller and the integrated b140 controller, in which I have the WS 2016 operating system in RAID 1. Currently in RAID 1 I have two 120GB OCZ TR150 disks with 20,000 working hours, and I would like to replace the two.

What would be the best system to replace the discs?

1 .- I make a backup of the operating system (I have backups made by Windows), change the disks and and reinstall the operating system of the backup? (I dont like this system very much).

2.- Replace a disk, let the system rebuild the new unit, and then replace the other and let it rebuild again.

The new discs that I want to incorporate are two Samsung 860 Pro 250GB, which have a larger size than the old OCZ. Once the two new 250GB disks are incorporated, will I be able to expand the total capacity from the SSA?

Thank you!


ML350 G6 Server: Error reading power values from microcontroller

$
0
0

Just wanted to ask  for help in following issue:

HP ML350 G6 server with redundant power supply, 750W each no errors during boot or in IML logs have error in the iLO2 interface related to power:

Error reading power values from microcontroller. No valid data can be gathered

Unable to communicate with power microcontroller

Server is updated to all current firmware and othervise runs OK, with only one issue: restarts itself after shutdown. (BIOS is set to: NOT RESTART AFTER SHUTDOWN)

System ROM: D22 (05/21/2018)

iLO2 Firmware: V2.33 (03/20/2018) Advanced version

RAM installed: 144GB 1333mhz (6 x 8GB + 6 x 16GB)

As reccomended in few old posts, server was shut down compleately, disconnected from power and restarted in 20 min, did not resolved the issue.

Any help would be much apprecaited.

 

Third-Party Software Update Catalogs in SCCM not able to download/Publish

$
0
0

Hi!

(Might be posted in the wrong location)

I'm a config manager (SCCM) administrator, and  in the latest release of SCCM 1806, they have included a feature called "Third-Party Software Update Catalogs" which basically means WSUS can handle third-party updates.

I am however having some issues with 1 out of 4 updates from the HPE catalog?!

I'm suspecting the bold-marked link below to be wrong. It is atleast not the same link when I Published/downloaded the other updates

[34, PID:8952][10/03/2018 14:15:57] :PollingWorkMonitor: There are 1 jobs that are pending the jobs table.
[34, PID:8952][10/03/2018 14:15:57] :PollingWorkMonitor: Starting job 72057594037927950 for subject 5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849.
[34, PID:8952][10/03/2018 14:15:57] :Creating a new SyncUpdate work item for update 5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849, jobid is 72057594037927950
[56, PID:8952][10/03/2018 14:15:57] :SyncUpdate: 'HPE ProLiant Server Firmware 2018.06.0 (Update:'5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849' Vendor:'HPE ProLiant Updates' Product:'Firmware Bundles')' is synchronized to WSUS without content, revision to add content is required.
[56, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Checking if certificate is registered for server %ServerName%
[56, PID:8952][10/03/2018 14:15:57] :SyncUpdate: 5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849 - Downloading file: 'http://updatespublisherlocalsourcepublishedsoftwareupdate/' to 'D:\ConfigMgr\ISVTemp\zpkimj12.vlr'.
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: An unexpected error ocurred attempting to download content from 'http://updatespublisherlocalsourcepublishedsoftwareupdate/':
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: ==================== Exception Detail Start =======================
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Exception type: WebException
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Exception HRESULT: -2146233079
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Exception Message: An exception occurred during a WebClient request.
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Exception source mscorlib
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Exception TargetSite Void ThrowForNonSuccess(System.Threading.Tasks.Task)
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: Stack at System.Runtime.CompilerServices.TaskAwaiter.ThrowForNonSuccess(Task task)
at System.Runtime.CompilerServices.TaskAwaiter.HandleNonSuccessAndDebuggerNotification(Task task)
at Microsoft.ConfigurationManager.ISVUpdatesSyncAgent.DownloadManager.Request.<DownloadFileAsync>d__24.MoveNext()
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: ===================== Exception Detail End ========================
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: WebException status : 'UnknownError
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: 5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849 - Download of update 5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849 failed, unable to continue
[34, PID:8952][10/03/2018 14:15:57] :STATMSG: (SRVMSG_SMS_ISVUPDATES_SYNCAGENT_UPDATECONTENT_DOWNLOAD_FAIL).
[34, PID:8952][10/03/2018 14:15:57] :STATMSG: (SRVMSG_SMS_ISVUPDATES_SYNCAGENT_UPDATECONTENT_FAIL).
[34, PID:8952][10/03/2018 14:15:57] :SyncUpdate: 5ccaf2ef-9fb4-4e85-8c34-cf04c07ef849 - Completed.

The custom catalog settings are listed here:
2018-10-03 14_43_45-Window.png

And this is the remaining updates which are downloaded/published fine: (exept the first one which is my issue)
2018-10-03 14_45_18-Window.png

Hope someone can help me :)

Best Regards

Christian

Find the latest firmware downloads for your Storage Disk Enclosures

AlertMail with PowerShell

$
0
0

How does one use PowerShell to set the AlertMail "Enable SMTP Secure Connection (SSL/TLS)" option on a Gen10.  I dont see any parameter to set this with the "Set-HPEiLOAlertMailSetting" cmdlet in the latest PowerShell module for iLO.

Thanks

NK

Problem with a Raid 1+0 array on a Proliant DL380 G7 - Smart Array 410i

$
0
0

We have a DL380 had system board failure. Specifically, the disk controller. Took a couple trips, but they got the machine back up and running. However, there is a problem with a RAID 1+0 array on the server.

The file system on this Raid is up and apparently fine.  Running RedHat.

The problem is that the array thinks it has 3 failed disks, and the controller thinks there are 3 spare disks.

array B (SAS, Unused Space: 0  MB)


      logicaldrive 2 (1.6 TB, RAID 1+0, Interim Recovery Mode)

      physicaldrive 1:5 (box 1:bay 5, SAS, 0 MB, Failed)
      physicaldrive 1:7 (box 1:bay 7, SAS, 0 MB, Failed)
      physicaldrive 1:8 (box 1:bay 8, SAS, 0 MB, Failed)
      physicaldrive 2C:2:7 (port 2C:box 2:bay 7, SAS, 300 GB, OK)
      physicaldrive 2C:2:8 (port 2C:box 2:bay 8, SAS, 300 GB, OK)
      physicaldrive 3C:2:2 (port 3C:box 2:bay 2, SAS, 300 GB, OK)
      physicaldrive 3C:2:3 (port 3C:box 2:bay 3, SAS, 300 GB, OK)
      physicaldrive 3C:2:4 (port 3C:box 2:bay 4, SAS, 300 GB, OK)
      physicaldrive 4C:1:1 (port 4C:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 4C:1:2 (port 4C:box 1:bay 2, SAS, 300 GB, OK)
      physicaldrive 4C:1:3 (port 4C:box 1:bay 3, SAS, 300 GB, OK)
      physicaldrive 4C:1:4 (port 4C:box 1:bay 4, SAS, 300 GB, OK)
      physicaldrive 5C:1:6 (port 5C:box 1:bay 6, SAS, 300 GB, OK, active spare)

   unassigned

      physicaldrive 5C:1:5 (port 5C:box 1:bay 5, SAS, 300 GB, OK)
      physicaldrive 5C:1:7 (port 5C:box 1:bay 7, SAS, 300 GB, OK)
      physicaldrive 5C:1:8 (port 5C:box 1:bay 8, SAS, 300 GB, OK)

 

Doesn't take long to see that there is a house keeping issue here.

We tried reseating one of the drives to see if that would get the controller to figure it out, but that didn't happen.

 

My next thought is that we could go in hpacucli and remove the "failed" disks and add in the spares.

  • Ctrl slot=0 array B remove drives=1:5,1:7,1:8
  • Ctrl slot=0 array B add spares=5C:1:5,5C:1:7,5C:1:8

Then, I'm not sure what command to use to get the spares to take over and be full members of the array and not just spares.

Is there any danger to this? If we have to, we can delete the disk and array, and rebuild them, but we already had a week long outage due to the failure, and would rather keep the machine up.

Any help would be appreciated?

 

thanks,.

Paul.

 

 

 

 

Error creating cache SSD for raid5 array

$
0
0

Hello all.

I have a ProLiant DL380 G6 with a Smart Array P410i. There is a need to create a disk cache for Logical Drive

ctrl all show config detail:

 

=> ctrl all show config detail

Smart Array P410i in Slot 0 (Embedded)
   Bus Interface: PCI
   Slot: 0
   Serial Number: 50123456789ABCDE
   Cache Serial Number: PAAVP9SYA66L
   RAID 6 (ADG) Status: Disabled
   Controller Status: OK
   Hardware Revision: C
   Firmware Version: 2.74
   Rebuild Priority: High
   Expand Priority: Medium
   Surface Scan Delay: 15 secs
   Surface Scan Mode: Idle
   Queue Depth: Automatic
   Monitor and Performance Delay: 60  min
   Elevator Sort: Enabled
   Degraded Performance Optimization: Disabled
   Inconsistency Repair Policy: Disabled
   Wait for Cache Room: Disabled
   Surface Analysis Inconsistency Notification: Disabled
   Post Prompt Timeout: 0 secs
   Cache Board Present: True
   Cache Status: OK
   Cache Ratio: 0% Read / 100% Write
   Drive Write Cache: Enabled
   Total Cache Size: 512 MB
   Total Cache Memory Available: 400 MB
   No-Battery Write Cache: Enabled
   Cache Backup Power Source: Batteries
   Battery/Capacitor Count: 1
   Battery/Capacitor Status: OK
   SATA NCQ Supported: True

   Array: A
      Interface Type: SAS
      Unused Space: 0  MB
      Status: OK
      Array Type: Data



      Logical Drive: 1
         Size: 820.2 GB
         Fault Tolerance: 1+0
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 65535
         Strip Size: 128 KB
         Full Stripe Size: 768 KB
         Status: OK
         Caching:  Enabled
         Unique Identifier: 600508B1001037383941424344451700
         Disk Name: /dev/sda
         Mount Points: None
         Logical Drive Label: A013004550123456789ABCDEA520
         Mirror Group 0:
            physicaldrive 2C:1:4 (port 2C:box 1:bay 4, SAS, 146 GB, OK)
            physicaldrive 2C:1:3 (port 2C:box 1:bay 3, SAS, 146 GB, OK)
            physicaldrive 2C:1:2 (port 2C:box 1:bay 2, SAS, 146 GB, OK)
            physicaldrive 2C:1:1 (port 2C:box 1:bay 1, SAS, 146 GB, OK)
            physicaldrive 3C:1:8 (port 3C:box 1:bay 8, SAS, 146 GB, OK)
            physicaldrive 3C:1:7 (port 3C:box 1:bay 7, SAS, 146 GB, OK)
         Mirror Group 1:
            physicaldrive 3C:1:6 (port 3C:box 1:bay 6, SAS, 146 GB, OK)
            physicaldrive 3C:1:5 (port 3C:box 1:bay 5, SAS, 146 GB, OK)
            physicaldrive 4C:2:4 (port 4C:box 2:bay 4, SAS, 146 GB, OK)
            physicaldrive 4C:2:3 (port 4C:box 2:bay 3, SAS, 146 GB, OK)
            physicaldrive 4C:2:2 (port 4C:box 2:bay 2, SAS, 146 GB, OK)
            physicaldrive 4C:2:1 (port 4C:box 2:bay 1, SAS, 146 GB, OK)
         Drive Type: Data

      physicaldrive 2C:1:1
         Port: 2C
         Box: 1
         Bay: 1
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD5
         Serial Number: BS05P890ESUW0838
         Model: HP      DG146BABCF
         Current Temperature (C): 33
         Maximum Temperature (C): 53
         PHY Count: 2
         PHY Transfer Rate: 3.0Gbps, Unknown

      physicaldrive 2C:1:2
         Port: 2C
         Box: 1
         Bay: 2
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD7
         Serial Number: 3NM3YNN900009819U07U
         Model: HP      DG146ABAB4
         Current Temperature (C): 30
         Maximum Temperature (C): 50
         PHY Count: 1
         PHY Transfer Rate: 3.0Gbps

      physicaldrive 2C:1:3
         Port: 2C
         Box: 1
         Bay: 3
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPDE
         Serial Number: 6SD3CAWK0000B142LPPC
         Model: HP      EG0146FAWHU
         Current Temperature (C): 29
         Maximum Temperature (C): 49
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 2C:1:4
         Port: 2C
         Box: 1
         Bay: 4
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD7
         Serial Number: 3NM3TB5R00009752Y4E9
         Model: HP      DG146ABAB4
         Current Temperature (C): 31
         Maximum Temperature (C): 48
         PHY Count: 1
         PHY Transfer Rate: 3.0Gbps

      physicaldrive 3C:1:5
         Port: 3C
         Box: 1
         Bay: 5
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD5
         Serial Number:         PCWUUMME
         Model: HP      DG0146FARVU
         Current Temperature (C): 28
         Maximum Temperature (C): 39
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 3C:1:6
         Port: 3C
         Box: 1
         Bay: 6
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD5
         Serial Number:         PCWWU1BE
         Model: HP      DG0146FARVU
         Current Temperature (C): 28
         Maximum Temperature (C): 39
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 3C:1:7
         Port: 3C
         Box: 1
         Bay: 7
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD5
         Serial Number:         PCWWTGRE
         Model: HP      DG0146FARVU
         Current Temperature (C): 29
         Maximum Temperature (C): 39
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 3C:1:8
         Port: 3C
         Box: 1
         Bay: 8
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 10000
         Firmware Revision: HPD5
         Serial Number:         PCWWVPSE
         Model: HP      DG0146FARVU
         Current Temperature (C): 31
         Maximum Temperature (C): 40
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 4C:2:1
         Port: 4C
         Box: 2
         Bay: 1
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 15000
         Firmware Revision: HPDG
         Serial Number: 6TB2A1970000B2033UNS
         Model: HP      EH0146FAWJB
         Current Temperature (C): 29
         Maximum Temperature (C): 40
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 4C:2:2
         Port: 4C
         Box: 2
         Bay: 2
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 15000
         Firmware Revision: HPDC
         Serial Number: 3TB0JX6K00009010V8W8
         Model: HP      DH0146FAQRE
         Current Temperature (C): 31
         Maximum Temperature (C): 60
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 4C:2:3
         Port: 4C
         Box: 2
         Bay: 3
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 15000
         Firmware Revision: HPDD
         Serial Number: 3TB143PT00009027TW0D
         Model: HP      EH0146FAWJB
         Current Temperature (C): 31
         Maximum Temperature (C): 59
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 4C:2:4
         Port: 4C
         Box: 2
         Bay: 4
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 146 GB
         Rotational Speed: 15000
         Firmware Revision: HPDC
         Serial Number: 3TB0KQJZ00009011WUYF
         Model: HP      DH0146FAQRE
         Current Temperature (C): 32
         Maximum Temperature (C): 60
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown


   Array: B
      Interface Type: SAS
      Unused Space: 0  MB
      Status: OK
      Array Type: Data



      Logical Drive: 2
         Size: 558.7 GB
         Fault Tolerance: 5
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 65535
         Strip Size: 256 KB
         Full Stripe Size: 512 KB
         Status: OK
         Caching:  Enabled
         Parity Initialization Status: In Progress
         Parity Initialization Progress: 4.11% complete
         Unique Identifier: 600508B1001037383941424344451E00
         Disk Name: /dev/sdb
         Mount Points: None
         Logical Drive Label: AD218B2950123456789ABCDE8CEC
         Drive Type: Data

      physicaldrive 5C:2:6
         Port: 5C
         Box: 2
         Bay: 6
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 300 GB
         Rotational Speed: 15000
         Firmware Revision: 0005
         Serial Number: 6XN2QE540000B324H25H
         Model: SEAGATE ST9300653SS
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 5C:2:7
         Port: 5C
         Box: 2
         Bay: 7
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 300 GB
         Rotational Speed: 15000
         Firmware Revision: 0005
         Serial Number: 6XN2CJEE0000B317C8TB
         Model: SEAGATE ST9300653SS
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown

      physicaldrive 5C:2:8
         Port: 5C
         Box: 2
         Bay: 8
         Status: OK
         Drive Type: Data Drive
         Interface Type: SAS
         Size: 300 GB
         Rotational Speed: 15000
         Firmware Revision: 0005
         Serial Number: 6XN766630000M503VXSK
         Model: SEAGATE ST9300653SS
         PHY Count: 2
         PHY Transfer Rate: 6.0Gbps, Unknown


   unassigned

      physicaldrive 5C:2:5
         Port: 5C
         Box: 2
         Bay: 5
         Status: OK
         Drive Type: Unassigned Drive
         Interface Type: Solid State SATA
         Size: 480.1 GB
         Firmware Revision: CS131122
         Serial Number: PNY09162169920311C89
         Model: ATA     PNY CS1311 480GB
         SATA NCQ Capable: True
         SATA NCQ Enabled: True
         SSD Smart Trip Wearout: Not Supported
         PHY Count: 1
         PHY Transfer Rate: 3.0Gbps


   Enclosure SEP (Vendor ID HP, Model HP SAS EXP Card) 248
      Device Number: 248
      Firmware Version: 1.52
      WWID: 50014380065CE765
      Box: 2
      Vendor ID: HP
      Model: HP SAS EXP Card

   Expander 250
      Device Number: 250
      Firmware Version: 1.52
      WWID: 50014380065CE766
      Box: 1
      Vendor ID: HP

   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 249
      Device Number: 249
      Firmware Version: RevC
      WWID: 50123456789ABCED
      Vendor ID: PMCSIERA
      Model:  SRC 8x6G

=>

but when I try to create ldcache I get the following error:

=> ctrl slot=0 create type=ldcache drives=5C:2:5 datald=2

Error: This operation is not supported with the current configuration. Use the
       "show" command on devices to show additional details about the
       configuration.
Reason: Not supported

 

What am I doing wrong?

Are there any other restrictions besides the ldcaсhe array?

 

Redhat linux OS installation

$
0
0

i need to install redhat linux 6.0 on DL 380 gen 10 server , so is it possible.?


Have an ML350 gen10 with e208i-a controller, Can I also use the onboard SATA controller?

$
0
0

I want to add a LFF drive cage to my ML350 gen10 with an e208i-a controller that already has 8 sff.  Is there a way to use the onboard sata controller for the LFF drives?  If not, how can I make it work?  buy another sata controller?  Any recommendations? I don't need hardware raid for the sata drives. 

How to add a sound card to Proliant DL380 G7

$
0
0

Hi 

I have a one question about ,"How can i install The sound card on the server Proliant DL380G7"

I installed the ESXI 6.0 on this server and now i need a sound card , can you guid me how can i use sound adaptor ?

 

thanks

I can't access to intelligent provisioning via F10.

$
0
0

as in the object I can't access to intelligent provisioning via F10 , on ML350 GEN10

As suggested in other posts, I installed the Intelligent Provisioning Recovery Media for Gen10 v. 3.20 but the problem persists.

I can't access to intelligent provisioning via System Utilities.

I can access to intelligent provisioning via Ilo. Here we can the see the wizard for the first configuration. I can run the wizard until the end, and arrive to see in the browser a a screen with teh following message : "Intelligent provisioning api is not registered yet.please wait while the server is booting to itelligent provisioning.....". meanwhile the server switches off and on automatically and goes to the home screen with only the F10 button visible and active: but the intelligent repository doesn't start.

What can I do ?

Thanks
Andrea

HPE Smart Array P816i-a SR Gen10 changing box number

$
0
0

Hi All,

 

I have 4 DL380 Gen10 servers with "HPE Smart Array P816i-a SR Gen10"

On 3 servers I have "Internal Drive Cage at Port 3I, Box 3, OK", on the 4th I have "Internal Drive Cage at Port 3I, Box 8, OK",

so my disk are named

 3I:8:1 (SAS HDD, 4.7 TB), 3I:8:2 (SAS HDD, 4.7 TB), 3I:8:3 (SAS HDD, 4.7 TB), 3I:8:4 (SAS HDD, 4.7 TB)

instead of

3I:3:1 (SAS HDD, 4.7 TB), 3I:3:2 (SAS HDD, 4.7 TB), 3I:3:3 (SAS HDD, 4.7 TB), 3I:3:4 (SAS HDD, 4.7 TB)

Is there any ways to rename box 8 in box 3?

 

Thanks

HP Insight Foundation Agents Properties

$
0
0

H90 DL380, Window 2008 r2.

Not able to start the service of HP Insight Foundation Agents in manual and Automatic.

Message :

Winodws could not start the HP Insight Foundation Agents service on Local Computer.

Error : 1608 : The dependency service or group failed to start.