Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

HP Proliant ML10 Gen9 Drivers Server 2016

$
0
0

hello, i'm new, please talk me where is download driver HPE ML10 Gen9 for windows 2016 standar. Thank you.


HPE ML350 Gen10 with both LFF and SFF - is it possible?

$
0
0

Hello,
I'm thinking about buying an ML350 Gen10 server (877621-421). It's an 8x SFF model with Xeon Silver 4110 processor and 16GB RAM. I was wondering if it's possible to additionally build in the 4xLFF HDD cage kit (874566-B21). That would physically give me 4xLFF + 8xSFF hot-swap drives. I understand this model comes standard with the HPE Smart Array P408i-p Gen10, to which I can connect 8 drives. I'm assuming the controller has 2x miniSAS connectors. I could wire one of those to the 4xLFF cage, and one to the 4x SFF cage. That would mean I lose connectivity to 4 of the 8 SFF drives, but that's no problem for me. I could install upto 4xLFF drives and 4xSFF drives simultaneously.

Does anyone know if this is possible? The quickspecs only talks about a 4x4x4 LFF or a 8x8x8 SFF configuration - never about a mix of SFF and LFF.

Extra info - in case you need more information:
I want to go this route because I want the Silver 4110 processor, and the systems that come with the 4xLFF cage only come with the Bronze processor. I'm not able to customise this with my local reseller.
Also, I preferably need both SFF and LFF: LFF for my storage drives, and SFF for my OS SSD's.

- This server is to replace our existing server: Superm***o; 2x XEON 5160 processors; 2x WD Black 7k2 2TB SATA in hw RAID1 (no cache) gives me 2TB of total storage which is almost full now. Current performance is good enough for us. (Most storage consists of Word documents, pictures and the like...)
- It's tasks will be VMware with fileserver (Linux, ~50 SMB users), firewall (pfSense) and digital signage (Linux/Xibo).
- New storage capacity needs to be about 8TB, hence I'm looking at 4x SAS or SATA drives, 7k2 LFF 4TB in hw RAID10 (2GB cache) (833928-B21).
- Becaus this type of storage might be rather slow (?), I'm planning to install the OSses on 2x SSD 240GB in RAID1 (P04556-B21).
- We are a non-profit, so cost is an big issue for us. 8TB of storage in 10k SAS or SSD is not affordable for us. Also 2.5" is out, because I think they are too expensive for the amount of storage that I need and my budget.

I'm also open to consider other options, but I do need 8TB of storage, a good enough processor, 16GB of RAM and my budget is ~4000 Euro. And please remember my actual/initial question is whether I can mix LFF and SFF drive cages in the ML350 Gen10.

Thank you so much for your help!
Martin.

CPU temperature

HP Smart Array P420i Controller physical failure error

$
0
0

Hello all,

I've encountered an error message at the HP Smart Array P420i Controller and its HPSA1 battery stating that the physical element is missing. I have the batttery capacitor, the errors are still showing. Does it mean that the controller is faulty and needs replacement ? The server is an HP Proliant DL380 Gen8.

Thank you,

Proliant Dl 580 G7 SPP

$
0
0

In one of our client has few DL 580 G7 servers and need to update the firmware, but it's not under warranty and also the HP support will not be there i hope for G7. is it safe to update the SPP.

he's running with Windows 2012

ilo5 snmp v3 query

$
0
0

I need to set up snmp v3 users on a large number of servers in iLO.  So, I want to do it using hponcfg (can send to a large chunk of servers at once through salt).  I did this on one server as a test.  The user was added.  However, when I attempt to send a query, I just get a timeout.  I set with: 

USER=username
AUTHPASS='authpass'
PRIVPASS='privpass'
PASSWORD='ilopass'
INDEX=1
cat > ilo_snmp.xml << EOF<RIBCL VERSION="2.0"><LOGIN USER_LOGIN="administrator" PASSWORD="${PASSWORD}"><RIB_INFO mode="write"><MOD_SNMP_IM_SETTINGS><SNMP_USER_PROFILE INDEX="${INDEX}"><SECURITY_NAME VALUE="${USER}" /><AUTHN_PROTOCOL VALUE="1"/><AUTHN_PASSPHRASE VALUE="${AUTHPASS}"/><PRIVACY_PROTOCOL VALUE="1"/><PRIVACY_PASSWORD VALUE="${PRIVPASS}"/></SNMP_USER_PROFILE></MOD_SNMP_IM_SETTINGS></RIB_INFO></LOGIN></RIBCL>
EOF
hponcfg -f ilo_snmp.xml

Is there another setting I need to change?  I've been reading the iLO5 user guide, but have not found the answer yet.  Currently running iLO vs 1.37 and using hponcfg vs 5.4.

Missing Base System Device Driver ProLiant DL380 G7

$
0
0

Hi all

Could you please help to identify drivers , i have ProLiant DL380 G7 with server 2016 installed on it

 

here the drivers

 

\VEN_103C&DEV_3307&SUBSYS_3309103C&REV_04\4&20dd2eef&0&02E4

 

thanks a lot for your help

 

 

 

Upgrading an ML350 G5 proliant server with a P800 array controller

$
0
0

Hi,

In my company we have a very old server Proliant 350G5 running Windows server 2003 with a P800 array controller. We are now looking into upgrading the whole system, mainly because windows server 2003 is no longer supported since 2015.

I searched the web but I couldn't find a definitive answer to this question: can I keep the P800 array controller if we buy a new proliant server, maybe the ML350 G10 with windows server 2016, or do I have to also buy a new array controller?

 

 


[ProLiant DL360e Gen8] NAND Error

$
0
0

 Hello everyone,
I am currently having issues with NAND error, currently error i have is: 
Controller firmware revision 2.10.00 NAND read failure: Media is in a WRITE-PROTECTED state

But it shuffles always.. Let me first tell you fully what have i tried doing, so i upgraded iLo to latest version 2.61 and there was error about NAND I did click 'Format Embedded Flash and reset iLO' after reboot it came up working BUT Intelligent Provision was not working still, so I tried updating it on latest version, after update i started seeing again NAND read failure, now I tried several times clicking 'Format Embedded Flash and reset iLO' it didnt work, then after a while i tried also over HPQLOCFG to run 'FormatFlash' script, which did not do anything, I even tried shuting down server and taking out power cords for few minutes and putting them back.

Here is log from script:

<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='No error'
/>
</RIBCL>
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='No error'
/>
</RIBCL>
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='No error'
/>
</RIBCL>
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='Forcing a format of the partition after the iLO reset.'
/>
</RIBCL>
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='No error'
/>
</RIBCL>
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='No error'
/>
</RIBCL>
<?xml version="1.0"?>
<RIBCL VERSION="2.23">
<RESPONSE
STATUS="0x0000"
MESSAGE='No error'
/>
</RIBCL>


Script succeeded

Any ideas what should I do to get it working again, and solve Intelligent Provision?
Looking forward to your answers!

HPE DL380p Gen8 P420i Self-test failure (cmd = 0h, err = 00h, loockup = 0DEAD: DEADh)

$
0
0

Greetings. I have a problem with the xxx server. When loading the server on the screen, I get the RADI-controller error: Slot 0 HP Smart Array P420i Controller Initializing ... 1783-Slot 0 Drive Array Controller Failure!  [Self-test failure (cmd = 0h, err = 00h, loockup = 0DEAD: DEADh)] The server does not load. A logical disk was made on the RAID array 1 + 0 of 4 disks 146 GB. There is no backup copy of the logical disk contents. I must save the contents of the disk when restoring the system. There is no contract with HPE for this server yet. There is no possibility to open paid repair. It is necessary to restore the server by local engineers. What can be done? If I move 4 disks to another similar server - is it possible to access the contents of the disk without losing it? On the second server, the layout of the RAID controller is similar to a broken server.

DL380 G6 reboot

$
0
0

hello,

i have problem in my server HP DL380 G6 that continually reboot  

i tried to replace RAMs it's still the same problem but when i tried to put the processor in slot2 it's boot normly and shows this msg "processor is not in the correct slot"

i think that the slot1 is damged 

Is there anything else I could try?

SN1100Q Status Lights

$
0
0

Will the status lights show "UP/ACT" as long as there is a fiber connection to a live port, or does that also require the LUN actually need to be configured and active in the OS? For example, a Gen10/SN1100Q server that is just sitting with a live fiber connection (assume 16Gb) but no OS, what should the status lights show?

Help to install Citrix XenServer 7.6 on HPE ML110 Gen10 with Smart Array S100i SR Gen10

$
0
0

Hi everyone,

I'm having problems to install XenServer 7.6 on the server as the Citrix doesn't recognize the RAID I configure with the HP SSA. When I have to select the disk to install XenServer give me the two disks available but not the array.

Thank you in advance for your help.

Alejandro

In hponcfg for iLO config, what's the difference between "YES" and "LOM" for "SHARED_NETWORK_PORT" ?

$
0
0

If you get your iLO network settings using hponcfg - there is a setting called SHARED_NETWORK_PORT - with falues of NO, YES, LOM, or FlexibleLOM.

I am trying to determine what the actual difference is between the values of "YES" and "LOM".  From the hponcfg scripting manual, the descriptions are identical, as quoted below:

Yes—Enables a NIC that is built into the server (a shared network port). The NIC handles
server network traffic and can, if ILO is configured to do so, handle iLO traffic at the same
time.
LOM—Enables a NIC that is built into the server (a shared network port). The NIC handles
server network traffic and can, if ILO is configured to do so, handle iLO traffic at the same
time. Not all servers support a LOM.

So what is the actual, technical difference here.  They both use NIC port 1 right?  What affect does switching from YES to LOM have, and vice versa?


I ask this because deployed out in the field, I have a ProLiant DL160 Gen 9, that for whatever reason, wasn't shipped with the optional iLO Management Port kit, that provides a dedicated iLO port; that all of our servers typically have.

This server is currently configured as "LOM" and, I am unable to access the iLO interface for it.   It's connected to an auto detecting speed switch, and the NIC 1 interface itself is working as that is how the server is connected and otherwise operational on the network.  Yet I can't get into the iLO.  

I am considering trying to switch it from "LOM" to "YES" for this value, to see if that helps.  But if I lose NIC 1 access as a result, I'll be unable to reach this server at all... 

Thank you in advance!

AMS crashes when stopping the service

$
0
0

When I stop the AMS service, it crashes the application and generate errors in Windows Error Reporting.

Faulting application name: ams.exe, version: 1.40.0.0, time stamp: 0x5c4798f9
Faulting module name: reversesnmp.dll_unloaded, version: 1.40.0.0, time stamp: 0x5c47984c
Exception code: 0xc0000005
Fault offset: 0x00000000000019e9
Faulting process id: 0xca0
Faulting application start time: 0x01d4eb0e1030583f
Faulting application path: C:\Program Files\OEM\AMS\service\ams.exe
Faulting module path: reversesnmp.dll
Report Id: ecde7995-0eb1-4a8e-ab8f-6ebd05e86da5
Faulting package full name:
Faulting package-relative application ID:

Is there a proper way to stop the service without generating crash events?  Is there some other service I should be stopping first.  Should I KILL the process intead of stopping the service?

Thanks

NK


Vsphere 6.7 Update 2 announcement

StorageWorks D3600 - "non-authentic" Warning in slots 1-6 only

$
0
0

We recently purchased a D3600 for a ZFS storage server, replacing an old Dell EMC appliance. Our configuration includes the following:

  • HP StorageWorks D3600 - 10x Seagate ST6000NM0034 DP SAS Drives & 2x HGST ZeusRAM SAS SSDs
  • HP Proliant DL360 G8 (ZFS1) - HP P241 Ext. SAS HBA
  • HP Proliant DL360 G8 (ZFS2) - HP P241 Ext. SAS HBA

The issue we're having is the HBA cards are throwing our warnings saying that our drives in a degraded state because they are non-authentic. The weird thing is only drives in slots 1-6 show this warning, while drives in slots 7-12 report as healthy. We are running the 4.04 firmware on the D3600 and firmware version 6.60 on the P241 cards. Has anyone else experienced similar behavior from their StorageWorks or HBAs? 

HP Proliant DL 380 Gen10 Server OS installation

$
0
0

Hey Everyone ,

I am trying to install OS Redhat Enterprise Server 5.4 on HP proliant Gen10 DL380. But when ever I selct  boot device CD-ROM OR  my San Disk USB front Device it took me into one time boot menu.  from that menu also i cheked everything is fine but its not booting.

can anyone help me my bootable device is detecting but after selcting its not booting from that device.

just redirecting me into one time boot menu again and again.

 

many thanks in advance

 

HP Proliant dl380e Gen8 Drivers

$
0
0

Hello,

I'm quite new to HP Proliant servers, but has acquired two of the above and need some drives for the Base System Device.  I have searched on the HP drivers pages and found others for the system, but not this.  Could you point me in the right direction?  Are there any CAB files available containing all system drivers?  Whilst the below is the only remaining device without a driver at all, some others are using Microsoft-selected drives, which you may suggest should be replaced...  We're running Windows Server 2019 on it.

 

PCI\VEN_103C&DEV_3307&SUBSYS_3381103C&REV_05
PCI\VEN_103C&DEV_3307&SUBSYS_3381103C
PCI\VEN_103C&DEV_3307&CC_088000
PCI\VEN_103C&DEV_3307&CC_0880

Raid Card Problem

$
0
0

Hello,

I have HP Supermicro Server Xeon. There i have hardware raid which is P212 model. I have installed server 2012 standard r2 and got hp array configuration utility software. Raid setup is created by my datacenter. I am just looking status of drives and health like battery etc. 

It has now Raid 1 and Raid 0 created. The problem i am facing is everything works perfect and i refresh array utility. But sometime i get error like No controller found please check cable etc. 

I direct contacted my datacenter they said its software related issues because drives and raid controller is working find. They checked cables too and said they are also fine. Now again raid status showing and after some days it again create same issues.

what is the issue any idea?

Viewing all 10362 articles
Browse latest View live