Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

DL380 Gen 10 SAS HDD installation

$
0
0
Hello I have a DL380 Gen10 Server (P06419-B21)
and I installed 3 SAS (846524-B21).
With intelligent provisioning the system can not see any disk do I have to set up anything to make them visible, the disks lights up but the system tells me that no disks are installed....any suggestions?
 

Is it possible to keep the HDD and install another controller ? In this case whitch would be the controller to get?

Do I need to buy anything else?

Thank'


Replace non-existent drive in array with unassigned drive

$
0
0

Hi,

I have a P420 card in a Gen 8 dl360e server and I've been having some problems with my RAID 10 array.
The drive in bay 1 has appeared to fail. I say appeared, because on taking the drive out and running it through a test suite it all checks out ok.
I'm thinking therefore that the problem lay in the cable, the card, or the backplane.
To try to narrow down the problem I changed the SAS cable and have moved from port 1 on the card to port 2.

What seems to be happening now is that the card is recognising all four drives, but also shows a 'failed' drive on the previously used port. This drive does not exist - as there is nothing connected to port 1.

So, I have my RAID 10 array consisting of three functioning drives on port 2, and one 'failed' drive that does not exist on port 1. I also have a functioning 'unassigned' drive on port 2. I presume this is left in the configuration as the card remembers there being a failed drive on port 1. I'm hoping I can remove this from the array and add the functioning unassigned drive for a rebuild. I cannot find a way of doing this - can anyone help?

Here's a screenshot of the ACU showing what I mean.

ACU-error.pngUnassigned drive should be used in place of failed imaginary drive

HPE DL3x0 Gen10 Chassis Intrusion Detection Kit

$
0
0

When a chassis intrusion detection kit has been place in a proliant dl3x00 kit the system will generate via ILO a log code in the ILO logs.

is anyone having experience or a "how-to" procedure that explains how a server can react ( shutdown/ refuse to start) when this kind of alert is detected on a server.

customer wants to use for protecting softwares/databases ==> PKI running on a server

 

thanks for your help !

HPE Smart Array S100i SR Gen10 Software RAID Problem

$
0
0

Hi, I'm facing some big troubles to install WS 2016 in a DL385 Gen10 server. I'll try to put the details chronologically:

- I make the software raid on the BIOS. I have 2 SSD M.2 SATA 1TB each, raid 1. SSA sees it correctly.
- I try to install WS with bootable DVD. When I try to put the drivers for the controller to get recognized, Windows says it does not contain any driver...
- I try with intelligent provisioning. It seems it's installing but after first reboot, a command prompt is opened to copy drivers and stuff, but it get an error at some point and crashes. It remains in a "bootloop" every time I reboot. I searched on google and it seems that's a common error and I have to update the intelligent provisioning.

- Now the RAID is recoginezed in the BIOS (I've cleared either the disks and the controller several times...) but the intelligent provisioning doesn't sees it and the SSA shows a warning and no logical or physical disk (code 267). Windows drivers doesn't work either and I've came to a dead end... I hope you can help me.

Thanks.

Move SmartArray P800 from server A (Proliant ML350 Gen5) to server B (Proliant ML350 Gen6)

$
0
0

Hi,

We have 2 servers in our company: server A which is an HP Proliant ML350 Gen5 with Windows Server 2003 and server B which is an HP Proliant ML350 Gen6 with Windows Server 2008.

We have a Smartarray P800 which manages an external HP Storageworks 60 equipped with 12 drives which is installed on server A and now we want to move it to server B. Would this be possible, considering the OS and hardware differences?

 

 

 

 

Сервер ProLiant DL360 Gen9 кэш перманентно отключён

$
0
0
Доброго времени суток!
 
Была произведена замена батареи контроллера RAID.
 
Контроллер p440ar
 
Статус кеша: Permanently disabled.
 
Подскажите как включить.
 
Заранее спасибо!
 
p440ar
 
p440ar

Centos installiation error

$
0
0

error while installing centos 7.5 in hp ml30 server with b140i Controller

ERROR:

he package kmod-hpdsa is required for this installiation.the package does not exit. This is a fatal error and installiatiom will be aborted

Using ssascripting to load a RAID config results in first array not being sda

$
0
0

Hi,

We have been using kickstart to auto configure servers since at least Gen 6 from what I have seen.  We have received Gen10 DL360 and DL380s and using our existing raid setup scripts with V3.40 of ssa tools, /dev/sda is not the first array after clearing the config through ssa gui in BIOS or using -reset flag when applying the config over an existing raid config of the same.

/mnt/source/pretools/ssascripting -i /mnt/source/pretools/raid-configs/hp-raid.ini -reset -e /tmp/raid-error.ini

If I don't use the -reset flag (such as when kicking the server again and it is already RAID configured) sda is properly mapped to first array in controller.  The DL360 Gen10 seems to not have this problem, but I have to confirm again to be sure.

hp-raid.ini

; Date captured: Wed Jun 12 23:45:43 2019

 

; Version: 3.30.14.0 2018-04-24

 

Action= Configure

Method= Custom

 

 

; __________________________ Controller Specifications SLOT 0 ________________________________

;

; Controller HPE Smart Array P816i-a SR Gen10, FirmwareVersion 1.98, License Keys Supported

; SerialNumber PEYHD0DRHC11WQ

; DriverName smartpqi

; DriverVersion Linux 1.1.4-115

; SSDSmartPath Supported

Controller= SLOT 0

; PowerMode= MaxPerformance

; SurvivalMode= Enabled

ReadCache= 10

WriteCache= 90

WriteCacheBypassThreshold= 1040

RebuildPriority= High

ExpandPriority= Medium

ParallelSurfaceScanCount= 1

SurfaceScanMode= Idle

SurfaceScanDelay= 3

Latency= Disable

NoBatteryWriteCache= Disabled

MNPDelay= 60

IRPEnable= Disabled

DPOEnable= Disabled

ElevatorSortEnable= Enabled

QueueDepth= Automatic

PredictiveSpareActivation= Disable

SanitizeLock= None

; PendingSanitizeLock= None

 

; Drive Write Cache Policies - uncomment to modify

; DriveWriteCacheUnconfigured= DEFAULT

; DriveWriteCacheConfigured= DISABLE

 

 

; Array Specifications

Array= A

; Array Drive Type is SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 1I:3:2 (SAS HDD, 1.2 TB), 1I:3:1 (SAS HDD, 1.2 TB)

Drive= 1I:3:2, 1I:3:1

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 1

RAID= 1

Size= 953837

; SizeBlocks= 1953459632

Sectors= 32

StripSize= 256

Caching= Enabled

; VolumeUniqueID= 600508B1001C8F8BD3CBB79719096978

 

; Array Specifications

Array= B

; Array Drive Type is SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 1I:3:4 (SAS HDD, 1.2 TB), 1I:3:3 (SAS HDD, 1.2 TB)

Drive= 1I:3:4, 1I:3:3

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 2

RAID= 1

Size= 953837

; SizeBlocks= 1953459632

Sectors= 32

StripSize= 256

Caching= Enabled

; VolumeUniqueID= 600508B1001CD670AD91AAA2CA04EE29

 

; Array Specifications

Array= C

; Array Drive Type is SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 2I:3:5 (SAS HDD, 1.2 TB), 2I:3:6 (SAS HDD, 1.2 TB)

Drive= 2I:3:5, 2I:3:6

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 3

RAID= 1

Size= 953837

; SizeBlocks= 1953459632

Sectors= 32

StripSize= 256

Caching= Enabled

; VolumeUniqueID= 600508B1001CF49909165BD97C34296B

 

; Array Specifications

Array= D

; Array Drive Type is SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 2I:3:7 (SAS HDD, 1.2 TB), 2I:3:8 (SAS HDD, 1.2 TB)

Drive= 2I:3:7, 2I:3:8

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 4

RAID= 1

Size= 953837

; SizeBlocks= 1953459632

Sectors= 32

StripSize= 256

Caching= Enabled

; VolumeUniqueID= 600508B1001CD71D7ECB3156B5715796

 

; Array Specifications

Array= E

; Array Drive Type is Solid State SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 3I:2:1 (Solid State SAS SSD, 400 GB)

Drive= 3I:2:1

SSDSmartPath= Enable

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 5

RAID= 0

Size= 381522

; SizeBlocks= 781357232

Sectors= 32

StripSize= 256

; VolumeUniqueID= 600508B1001CCB52B6CEFADB958C2195

 

; Array Specifications

Array= F

; Array Drive Type is Solid State SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 3I:2:2 (Solid State SAS SSD, 400 GB)

Drive= 3I:2:2

SSDSmartPath= Enable

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 6

RAID= 0

Size= 381522

; SizeBlocks= 781357232

Sectors= 32

StripSize= 256

; VolumeUniqueID= 600508B1001CB8EF0CDE495993CEFE5D

 

; Array Specifications

Array= G

; Array Drive Type is Solid State SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 3I:2:3 (Solid State SAS SSD, 400 GB)

Drive= 3I:2:3

SSDSmartPath= Enable

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 7

RAID= 0

Size= 381522

; SizeBlocks= 781357232

Sectors= 32

StripSize= 256

; VolumeUniqueID= 600508B1001C9AF77D97B968E2488924

 

; Array Specifications

Array= H

; Array Drive Type is Solid State SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 3I:2:4 (Solid State SAS SSD, 1.3 TB)

Drive= 3I:2:4

SSDSmartPath= Enable

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 8

RAID= 0

Size= 1526153

; SizeBlocks= 3125562032

Sectors= 32

StripSize= 256

; VolumeUniqueID= 600508B1001C863E09C43D1D275F655C

 

; Array Specifications

Array= I

; Array Drive Type is Solid State SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 4I:2:5 (Solid State SAS SSD, 1.3 TB)

Drive= 4I:2:5

SSDSmartPath= Enable

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 9

RAID= 0

Size= 1526153

; SizeBlocks= 3125562032

Sectors= 32

StripSize= 256

; VolumeUniqueID= 600508B1001C00D3DA5974322DC0705C

 

; Array Specifications

Array= J

; Array Drive Type is Solid State SAS

; Array Block Size is 512 bytes

; Array Free Space    0.0 GBytes

; 4I:2:6 (Solid State SAS SSD, 1.3 TB)

Drive= 4I:2:6

SSDSmartPath= Enable

OnlineSpare= No

 

; Logical Drive Specifications

LogicalDrive= 10

RAID= 0

Size= 1526153

; SizeBlocks= 3125562032

Sectors= 32

StripSize= 256

; VolumeUniqueID= 600508B1001CEB17FB1CDD7776FB92D1

 

; PORT Specifications

Port=1I

; PortMode= Mixed

 

; PORT Specifications

Port=2I

; PortMode= Mixed

 

; PORT Specifications

Port=3I

; PortMode= Mixed

 

; PORT Specifications

Port=4I

; PortMode= Mixed

 


DL380 GEN8 - ILO Errors

$
0
0

Hi all,

I´ve a few DL380p G8, and fans speeding up to 100%, takes me to update all ILO and Bios for last version, all system are ok with two exceptions two DL380p G8 wich serial number is one after other, at same production. The error reports bad ILO initialization, looking corrections the ways are downgrade to 2.61 and cross fingers for a correction at ILO Chip (SD/Nand) or format the ilo, any help to correct it will be welcome.

On diagnostics, we have a Embedded Flash/SD-CARD with Controller Firmware revistion 2.10.00 and Embedded media initialization failed due to media write-verify test failure.

Can anyone help me solve this problem?

Thanks.

Nélio Abreu

 

Monitor port status for DL360 Gen9 and Gen10 servers

$
0
0

Hi all,

I am running snmpwalk to monitor the ports on DL360 Gen9 and Gen10 servers

Can I have idea about port status, what 1, 2 and 4 means.

[root@zabbix01 ~]# snmpwalk 172.30.57.4 -v 2c -c halcyon .1.3.6.1.4.1.232.18.2.3.1.1.13
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.2 = INTEGER: 2
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.3 = INTEGER: 2
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.4 = INTEGER: 2
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.5 = INTEGER: 2
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.6 = INTEGER: 2
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.7 = INTEGER: 2
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.8 = INTEGER: 4
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.9 = INTEGER: 1
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.10 = INTEGER: 1
SNMPv2-SMI::enterprises.232.18.2.3.1.1.13.11 = INTEGER: 1

configuring Array Controller in DL380 G( server

$
0
0
i just got a new server HP DL380 gen 9 server , on the intelligent provisioning , all am seeing is unassigned drive and physically i can see 8 new hard drives (SAS) . i can creat array controller . any way out.

ASR Error on ProLiant DL380 G5

$
0
0

Hello guys, I got this error this morning when I came back to office: 

Severity Class Last Update Initial Update Count Description

Critical
ASR
06/13/2019 23:39
06/13/2019 23:39
1
ASR Detected by System ROM

System doesn't boot anymore (also BIOS don't start) and my front panel show this: https://ibb.co/QD62BsM

ATM I haven't try to remove DIMMs, will be my next check.

Anyone have ideas?

Thanks, Alessandro

HP ProLiant DL180 Gen9 processor support

$
0
0

Hello!

A few years ago I bought a server HP ProLiant DL180 Gen9, now there is a question of replacing the processor E5-2603v3 on E5-2676v3 or E5-2667v3, but I can not find a list of supported processors.

Tell me where you can see the compatibility.

HPE Smart Array P408i-a SR Gen10 - RAID6 (ADG)

$
0
0

Guten Tag

Server: ProLiant ML350 Gen10
Product ID: 877623-421
Storage Controller: HPE Smart Array P408i-a SR Gen10

Disk: SAS 600GB
Model: EH000600JWHPN
Geschwindigkeit: 15k
Anzahl: 8
Fehlertoleranz: RAID 6 (ADG)

Ich verwende einen HP ProLiant ML350 Gen10 mit einem Smart Array Controller P408i-a Storage Controller. Ich habe 8 Stk. Disk in einem RAID (ADG) Verbund.

Ich habe schon mehrmals von Berufskollegen mitbekommen, dass ein RAID 6(ADG) nicht optimal mit 8 Disk arbeitet. Ideal wären fünf Disk oder neun Disk. Der Controller könne so optimaler arbeiten.
Hat jemand schon Erfahrungen damit gemacht oder weiss jemand etwas davon ?

Ich freue mich auf einen Antwort und danke euch für eurte mühungen.

Gruss

Chris

10G ethernet adapter with "ethernet RJ45 port interface" for DL360 G7 server?

$
0
0

Hello,

We have a customer that is looking for the product described as:

10G ethernet adapter with "ethernet RJ45 port interface ", not an SFP interface

Which option would this be?

They purchased a 516937-B21 but that wasn't satisfactory.

Any advice?

Thanks!


install slim DVD in ML350 Gen 10

$
0
0

Just got an ML350 Gen 10.

We also got a slimline DVD drive for it but I can't see anywhere it would fit into. It's smaller than the 3.5" wide hole. Is there a bracket/adapter I need?

Hard disk compatibility

$
0
0

I wonder if Hewlett Packard Enterprise Serwer DL20 Gen10 works with 1TB SATA 7.2K LFF SC HDD 861691-B21  disk? I would like to know if that disk won't cause any warnings from iLO and if I be able to create RAID (even using one disk, as it is required, even when one only disk is installed)

FlexBoot - Mellanox

$
0
0
Hi Guys,

I’m trying to get into the FlexBoot configuration menu of my Mellanox FlexLom card. It should present itself as a boot device or give me the option in the boot menu or allow me to press CTRL+B but neither way seems to work.

I’ve tried UEFI Bios/Legacy Bios and turning Secure Boot on and off.

I have the 640FLR-28SFP card and version 3.5.701 of FlexBoot. I’ve ran the latest SPP and so all firmware is current.

This is a DL360 Gen10 box. Any ideas?

Networking Issues on ProLiant DL380G6

$
0
0

I have a ProLiant DL380G6 with 4 NICs installed plus an iLO card. 3 out of my 4 NICs are connected and my iLO card is connected. After replacing a hard drive in my server, I can no longer access iLO, and I can't access the internet or ping my default gateway from my OS. 

During my OS boot I get errors that say:

[Firmware Bug]: the BIOS has corrupted hw-PMU resources (MSR 38d is 330)

ERST: Failed to get Error Log Address Range.

power_meter ACPI000D:00: Ignoring unsafe software power cap!

bnx2 0000:02:00.1: firmware: failed to load bnx2/bnx2-mips-09-6.1b.fw (-2)

 

Things I have tried to troubleshoot:

- Activated backup system ROM

- Reset NVRAM

- Disabled iLO 2

- Flashed server BIOS

- Reinstalled OS

- Deleted and re-created logical drive

DL360p gen8 fan speed

$
0
0

Fans of My server work whit 94% speed.

My frimware is 2.70 May 07 2019

my rom =P71 01/22/2018

how i can con configure my fan speed?

thanks for your answers.

Viewing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>