Can't install AMS in window server 2016 standard


Flashing health and amber power leds

$
0
0
I just got a new HPE ML30 Gen10. The Server was running 100% and booted into Server 2019 Microsoft Windows. The I restarted the Server and then it just started flashing the HEALTH LED in RED and the A, POWER LED in AMBER. The Server is not starting up at all it looks like it is in a system critical state and is staying is that state. What fault finding must I do to correct this problem?

ProLiant DL388 Gen8 无法开机 健康状态闪红灯

$
0
0

通电开机后过一段时间会进入待机状态,并且健康状态灯频闪红色,再按开机键无反应,硬盘指示灯不亮,已经检查过内存与电源,依然无法启动
检查过内存与电源,内存与电源都尝试更换过,但无效果,依然无法开机

指示灯实际为红色

ProLiant DL388 Gen8 won't power on

$
0
0

通电开机后过一段时间会进入待机状态,并且健康状态灯频闪红色,再按开机键无反应,硬盘指示灯不亮,已经检查过内存与电源,依然无法启动
检查过内存与电源,内存与电源都尝试更换过,但无效果,依然无法开机

Google Translated

After a period of time after power-on, it will enter the standby state, and the health status light flashes red. Pressing the power-on button has no response. The hard disk indicator is off. The memory and power have been checked. The power supply has been tried and replaced, but it has no effect and still cannot be turned on.

指示灯实际为红色

Trying to upgrade MO0400JFFCF hard drive firmware

$
0
0

I have a server that has Multiple drives that need firmware updated. I have tried upgrading through VMWARE, SUM and bootable USB.

Vmware and SUM give me this error

./CP042215.vmexe
Executing ESXi65 binaries and copying to current directory
Online HDD/SDD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK, and MO3200JFFCL Drives (HPD8), searching...
============ Summary ============
Smart Component Finished
Exit Status: 6
Device appears more than once in tree
Duplicate Device: /AC:2840541910/RV:600C0FF0003C0EE4243DFC5A01000000,V:1 already in tree @ /AC:2184388683/RV:600C0FF0003C0EE4243DFC5A01000000,V:1
exception while building hardware inventory
An internal tool error occurred. See engineering log for details.

The USB Drive says its already to baseline version. I have added the linux files to the packages folder on that drive.

 

Any help is welcome.

 

Thanks

Firmware update failed

$
0
0

This is a brand new HPE Proliant ML350 Gen10 P/D P11053-001
I mounted the firmware update ISO (P19473_001_spp-2019.09.0-SPP2019090.2019_0905.39.iso) to a USB thumbdrive and booted from it. It reached the question asking automatic or interactive update and I chose automatic.
I got message:
Starting initrd...
Warning !!! Unable to mount the file system [cdrom]
Warning !!! Unable to mount the file system
Preboot maintenance mode
/bin/ash: can't accesstty: job control turned off
#

I am stuck here.
The firmware updates also fail from within Intelligent Provisioning. with message "Error: unexpectedly disconnected from boot status daemon.
Then Error: Invalid cluster:0
There is no way to update firmware.

Proliant 5000 Power Supply Maintenance Key

$
0
0

I am unable to locate a source for the Compaq Proliant 5000 “Power Supply Maintenance Key”, part number 148757-001. It is a small white plastic key about 1 inch long that defeats the cover interlock switch. I have attached an image of the part taken from the maintenance manual. Does anyone know of a place that sells this part? Alternatively, if someone has one they’re willing to part with it would be appreciated.

148757-001 4500 pg 2-2 .png

ML350 G5 Boot Loop

$
0
0

Hello, 

I Know this is a old server, but its at home, so its fine for what I use it (or was).

So the problem: had 2 red lights blinking on the fornt panel, wouldnt start at all. unpluged power, ram, battery, reset the bios everything, nothing worked. Started unpluging internal cables, unplugged the backplane power cable, it started! 
Problem 2: Fans start, is on for about 5 seconds, turns off, turns on again, turns off in an infinite loop. Never see anything on screen. 

Any ideas?


Expand disk space for Proliant DL380 Gen9

$
0
0

Hello.

I started to manage a running Proliant DL380 Gen9.

It has a Smart Array P440ar Controller with 6 x 600GB SAS 15K Small factor HD in RAID 5.

I need to add more storage (4TB) for file sharing. I don't need a very fast solution, and RAID1 would be ok.

What are my bests options?

If I add two 4TB drive in the two free slots in the existing cage, would it be possible to create a new array in RAID1 without breaking the existing configuration?

Thank you very much for your advice.

 

 

 

DL360 gen10 - ROKWin Server 2016 - mass storage device yellow exclamation mark at device manager

$
0
0

Hello,

i have a challenge. i have 7 new Proliant DL 360 gen10. All are installed with HPE ROK Windows Server 2016. The RBSU config is at all server the same. I made the Driverupdates with the SPP - SUM. 

Now i have 4 Server which have a exclamation mark at a usb mass storage device in the device manager.. 3 Server don´t have the usb mass storage device in the device manager shown - so they also do not have the exclamation mark :). I do not find any driver for this usb mass storage device. I do not know which hardware this is. is this hardware which is virtually routed?

thank you very much for some support

best regards 

Jan  

 

 

HPE Proliant ML110 Gen10

$
0
0

I'm configuring a new Proliant ML110 GEN10 and trying to instal windows server 2016, I figured I could get to it through Intelligent Provisioning by hitting F10, once there i get a error message "reisntall intelligent Provisioning", I then attempted to reinstall Intelligent Provisioning via iLo remote media. I'm able to boot into the iso but then the installation fails with the error message "the firmware version of iLO is old can´t continue whith the flashing". after that i was unable to get in F10 menu.


IP Version IP340.2019_1106.196

HP DL380P GEN8 LFF 96TB SAS

$
0
0

Hello, what controller Support 12X8TB SAS 12G ?
Server HP DL380P GEN8 LFF 

HP DL380 G9 changed battery but 440ar controller says "no battery"

$
0
0

Hello,

I have three HP DL380 G9 servers. I have added three BBU one for each server.

In first server all was ok.

In the second server it says no bbu.

In the third server the battery is always "recharging".

What can I do? Should I change the 440ar controllers?

Thanks,

Mario

Does hp raid controller really use ram cache for ssds?

$
0
0

Hello,
in a 440ar controller I have built a raid1 with sas disks and several raido0 with ssd disks.

I then disabled ssd smartcache and added controller cache.

SAS disk performance improved greatly using controller cache.

SSD improved nothing. I suspect the controller does not use its ram cache when the disk is ssd.

Or is it possible that with raid0 no ram cache is used?

Thanks,

Mario

Dl380 gen7 server and 1TB SAS drive issue

$
0
0
I recently got my hands on an HP proliant dl380 Generation 7 server. I'm using it for self-education and experimentation. The first thing I did was look for good SAS drives for it.


I was able to find some used but certified good HP 1tb SAS drives, part number 72511 8 - 0 0 1. However, when the drives are plugged in and the system Powers up the drive lights up Amber and the system sees the drive as failed. I don't believe the drives are actually failed, and I'm wondering if perhaps this model is not compatible with the gen7 server? Is that a possibility? Does anyone know if these drives will work in the gen7 server?

They came pre-installed in trays from a different server with yellow tabs handles and the number 72739 7 on the front. The drive also has a label on it with the following part number : 72857 5 - 0 0 1.

Any help or advice is appreciated. Thanks in advance!

DL385 G7 Question

$
0
0

Hi am sorry if this has been asked before but need to ask.

Iv got my self a DL385 G7 for cheap of ebay 

I perched it as its got 2 12 core cpus and 128 gb ram so i want to use for Vmware 

Now when i looked up uo the specs of the cpu it supported what i needed to run esxi they way i wanted to.

but after getting it and doing more resurch i found the cou does what i need but no the server its self.

I wan to use pash thought to run an gpu for windows 10 as a vurtual machine. 

is there wany where to enable virtualizating to get pass thought to work on esxi or is that not possible with this server.

If its doesnt work ill take esxi off and install windows that way

HPE DL20 Gen10 No Controllers Detected

$
0
0

Hello,

I have a new sever hp DL20 Gen10. when I am trying to enter in smart storage administrator (version 3.40.3.0). But, under smart array controllers, I see " NO CONTROLLERS DETECTED".  I have also noticed my hard drives immediately turn orange. 

I've seen post where users are instructed to make sure controller is seated on the system board, or plugged into the PCIe slot. I have opened server, and from what I can tell, everything is connected.

Is there a driver I need or do I need to enable something, because I cannot get my drives to be seen.

Here's what i have done so far...

checked:

boot mode: UEFI

controller:  HPE Smart Array S100i SR Gen10 - when I go into controller information, no disks are found

 

When I check in System Utilities > System Information > Storage Device Information, I see

- NOTHING

 

When I check in System Configuration, I see

- BIOS/Platform Config (RBSU)

- iLO 5 Configuration Utility

- Embedded Storage:  HPE Smart Array S100i SR Gen10

- Embedded LOM1 Port1: HPE Ethernet 1Gb 2-port 332i Adapter - NIC

- Embedded LOM1 Port2: HPE Ethernet 1Gb 2-port 332i Adapter - NIC

 

When I check in RBSU  -> PCI device Information, I see

- Embedded LOM1: HPE Ethernet 1Gb 2-port 332i Adapter - NIC

- Embedded SATA Controller #1: HPE Smart Array S100i SR Gen10

ML350 Gen10 GPU power Cable

$
0
0
I have an Nvidia RTX 4000 that I want to add to my Gen10 ML350 but the 8pin connector on the power distribution board is smaller then the regular 8pin GPU cable. Is it a proprietary pin connector? I googled until I couldn't anymore haha.

SCO OPENSERVER 5.0.7

$
0
0

Can any one suggest and help me in installing SCO OPENSERVER 5.0.7 on HP Proliant ML310e Gen.8 v2 server please

Thanks in advance

HPE DL380 GEN 10 : Cant install windows 2016 server

$
0
0

when trying to unstall windows 2016 server using intelligence provisioning and windows ISO file from remote computer.

the copy and the extraction of the file is sucssesful but when the server reboot i got the following error :

WINDOWS COULD NOT PARSE OR PROCESS THE UNATTEND ANSWER FILE FOR PASS [SPECIALIZE].

 

Any idea or support on how to fix this issue ??