HP ML350p G8 GPU RTX 2080TI compatability

$
0
0

Hello! I'm choosing gpu for ML350p G8 Server with 2x Intel Xeon E5 2660, 32 gb ram.

I would like to install 1-2 RTX 2080ti GPUS, but In quickspecs i found info only about support of older ones. Does anybody have any experience in using ML350p server with modern GPUs?


HP Proliant ML 110 G6 no video and 4-3-3-1 beeps

$
0
0

Hello, I hope someone can help me because Im crazy with this problem.

I have a HP Proliant ML 110 G6 that was working perfectly, it has intel x3470 processor and 8gb of dual ram ecc, with this configuration it was working well with UNRAID.

One day electricity suddenly goes off, when it cames back my server turned on but has no video and this horrible beeps at the beginning, I have tried to change to the original processor, tried another rams, another slot, change power supply, clean bios and disconnect all non essential but still have the same problem.

Can anyone with this or similar problem help me?? I think this is a hardware failure but I don't know if I can repair it and what thing is it.

 

Thank you for you help.

Procedures for getting Serial Numbers of installed DIMMs on HP bl460c gen9 blades

$
0
0

Hi Team,

I'm humbly asking for your asssistance on how can I get the serial numbers  of installed DIMMs on our HP bl460c gen9 blades that we will use for our assessment on our ongoing expansion for virtualization. I'm not currently familiar with HP CLI commands that need to run to get the desired output. Also, appreciate if you can give me service impact assessment considering I will run the commands on production. I tried to run linux based commands like dmidecode but the Serial Number is not specified on the output similar to below. 

[root@ggtr01-bc01s01-ems01:Active ~]# dmidecode -t 17
# dmidecode 2.12
# SMBIOS entry point at 0x788fb000
SMBIOS 2.8 present.

Handle 0x000C, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x000A
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: None
Locator: PROC 1 DIMM 1
Bank Locator: Not Specified
Type: DDR4
Type Detail: Synchronous Registered (Buffered)
Speed: 2133 MHz
Manufacturer: HP
Serial Number: Not Specified
Asset Tag: Not Specified
Part Number: 752369-081
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum Voltage: 1.2 V
Maximum Voltage: 1.2 V
Configured Voltage: 1.2 V

 

Hope you can help me on this matter. Thank you.

 

Best regards,

Joel

 

Unable to load Win2k16/19 on RAID 1 built array on P816i-a Controller

$
0
0

Hello,

Having a terrible time trying to find a answer, I'm trying to install WIndows 2016 or 2019 on this brand new DL380 Gen10 and even through manual installation, even when I load the controller drivers, it recognizes the array and the JBOD disks, but the RAID1 Array I created on Disks 0 and 1 just don't show up on the list...

This also happened in IP as well, this is a brand new just cracked the box right off the car lot server. I've not done any firmware updates or any changes outside of just trying to load the OS, if someone could help that would be great as i'm really not wanting to utilize software RAID on this expensive server lol

DL360E gen8 ilo 4 ILO Command Error

$
0
0

Hello,

Boot into F8, write ILO network configuration. But unable to open ILO
ping IP is down

I choose to go to F10 again
It shows ILO Command Error

How should I fix it? Please advise

HPE Smart Array S100i SR Gen10 не видит SATA диски

$
0
0

Приобрели недавно сервер DL325 Gen10 при первичной настройке не удается создать RAID.

В поставке были установлены 4 LFF SATA диска по 4 ТБ, система их определяет и находит, но при включении встроенного HPE Smart Array S100i SR Gen10 и он выдает что подключено 0 физичеких дисков.

HPE Smart Array S100i SR Gen10 does not see SATA drives

$
0
0

Приобрели недавно сервер DL325 Gen10 при первичной настройке не удается создать RAID.

В поставке были установлены 4 LFF SATA диска по 4 ТБ, система их определяет и находит, но при включении встроенного HPE Smart Array S100i SR Gen10 выдает что подключено 0 физичеких дисков. Из ограничений нашел только что встроенный S100i не поддерживает SAS диски, но с SATA должен работать, в моем случае используются именно SATA, но они всеравно не отображаютя.

Google Translated

Recently purchased DL325 Gen10 server during initial setup, unable to create RAID.

The delivery included 4 LFF SATA disks of 4 TB each, the system detects and finds them, but when the built-in HPE Smart Array S100i SR Gen10 is turned on, it shows that 0 physical disks are connected. Of the limitations, I found that the built-in S100i does not support SAS disks, but it should work with SATA, in my case it is SATA that is used, but they still do not display.

HP DL360 G5 amber lights, then starts up

$
0
0

Hi, I have a hp dl360 g5 server with dual "QUAD XEON E5440 2.83GHz 12MB", 32gb of ecc ddr2 ram, and a 32gb pendrive with ubuntu 20.04 lts in the internal usb.

Recently it has started to not power up directly, sometimes when you press the 'on' button, both cpu amber lights on the insight display come on, the server doesn't start, and then after 1-5 min out of nowhere, the lights go off and server starts to boot. From what I know, if the cpu's were bad, the system would never start.

Why would it do that? One day I had to reboot the system quickly few times in a row, could anything happen while rebooting? One thing i noticed is that when the system was running, the heatsing right behind the two cpus, under a metal bracket for pci card, was getting pretty hot, can it be the cause?

I need the server to be up and running as quickly as possible, because of the raid I had on it with pretty valuable data. 


HP DL360 G5 CPU amber lights, after few minutes it starts up

$
0
0

Hi, I have a hp dl360 g5 server with dual "QUAD XEON E5440 2.83GHz 12MB", 32gb of ecc ddr2 ram.

Recently it has started to not power up directly, sometimes when you press the 'on' button, both cpu amber lights on the insight display come on, the server doesn't start, and then after 1-5 min out of nowhere, the insight lights go off and server starts to boot. From what I know, if the cpu's were bad, the system would never start.

Why would it do that?

One day I had to reboot the system quickly few times in a row, could anything happen while rebooting? One thing i noticed is that when the system was running, the heatsing right behind the two cpus, under a metal bracket for the pci card, was getting pretty hot, can it be the cause?

I need the server to be up and running reliably as quickly as possible, because of the raid I had on it with pretty valuable data. 

P.S. The server does it on every single powerup, both cpu lights are on, and after few minutes they go off and server starts up, in ILO2 there is no data about cpu errors it in the error messages.

Power Fault

$
0
0
I have a DL360p Gen8 that sometimes gets this power fault:

EVENT (19 Sep 02:25): System Power Fault Detected (XR: 10 00 MID: FF 0D FC 06 FF FF 2F 2F 0C 0C 40 7F 00 00 03 01 92 00 00 00 00 40 00 00 00 00 00 00 00 00 00 00)

System rom P71 05/24/19.

Can someone please decode this? Thanks.

ProLiant DL325 Gen10 / Debian 10

$
0
0

I am loving my new ProLiant DL325 Gen10, I used iLO to remotely mount Debian / Proxmox ISO, the install was uneventful.

I ran a complete update, and installed amsd hponcfg ssa ssacli ssaducli storcli from the HP mcp repository.

Everything seems fine, however when I try running "reboot" command, my server shuts down and doesn't come back to life. I have to do a power reset in iLO bring things back to life.

What am I missing?

ProLiant DL325 Gen10 / Debian 10 reboot fails

$
0
0

I am loving my new ProLiant DL325 Gen10, I used iLO to remotely mount Debian / Proxmox ISO, the install was uneventful.

I ran a complete update, and installed amsd hponcfg ssa ssacli ssaducli storcli from the HP mcp repository.

Everything seems fine, however when I try running "reboot" command, my server shuts down and doesn't come back to life. I have to do a power reset in iLO bring things back to life.

What am I missing?

Network Activity LED (DL360p Gen8)

$
0
0
What exactly controls the network activity LED on a DL360p Gen8?

I have two servers where it never lights, and the configuration is nearly the same as the others (10gb card in the FlexibleLOM slot) but these have an Ethernet NIC in the “large” PCI express slot instead of the “small” one.

Not a big deal, but it would be nice to understand.

HP Proliant DL380 Gen7 not powering on.

$
0
0

Hello,

i left my server off for some days. When i needed to turn it on i found that the power led was solid amber and pressing the power button did nothing. I tried removing both power supplies and reconnecting them, and now the power led does not even turn on, i can hear a sort of 'tickling' from the inside of the server and the UID led flashes blue once just when i connect the psus. 

By removing both power supplies and connecting only one i realized that one psu turns on the leds on the motherboard while the other one does nothing.

Could it be related to a psu failure? Shouldn't it start with just one working psu?

iLO AD integration

$
0
0

Hi

I see lots of people attempting to integrate iLO with their AD server and I'm also having issues - but I first have a very basic question to help me on my way.

I've have found the following technote from HPE - it's quite old but I believe still relevent as I'm using iLO 4 currently but will be upgrading to iLO 5 over the coming weeks.

https://slice2.files.wordpress.com/2013/03/integrating-hp-ilo-with-ad-and-cs1.pdf

The article first talks about upgrading the iLO firmware on page 1 and then on page 2 talks about how to configure certificates and then finally towards the bottom of page 5 about creating an AD security group and downloading the utility for the AD integration.

My simple question is "Do I need to complete the steps on page 2 for configuring a certificate in order to be able to integrate iLO into AD?" If I start on page 5 and ignore the steps about configuring certificates should it still work -  but I'll just continue to get the browser warning saying the site is not secure?

Thanks

C


Bios Update?

$
0
0

hi i have an hp pavilion laptop. i replaced the bios battery but still loose time. whats my next step?

Bios Update?

Can't find information about several old servers

$
0
0

Hi!

I need some info about: 

HP DL380 Gen.8

ProLiant DL180 G6

ProLiant DL360 G7

ProLiant DL360 G7.

Life time of this server, 

Are HP producing they,

Upgrade recommendations,

is their technical support provided?

I cant find this info on web site.

Thx for help!

 

Help with ProLiant Microserver G8 Drivers

$
0
0

I run Windows 10 on the Proliant Microsever G8 and recently change the C drive for a new one. After installing Window 10 I find that the device manager shows the Base System Device has no driver installed.  I have searched many times to try and find the driver with no joy.  Can anyone point me in the right direction?

Thanks.

SFTP and Telnet very slow

$
0
0

Hi All,

I have been working with a sftp site which is in a WAN network, the sftp was working fine from HP DL 386 Gen 9 server, from last one week am not able to connect to the sftp site in a usual way, it is taking abnormal delay in connecting the site, whereas i am able to connect to the same site from another LAN Ip without any issues. I have checked the firewall and switch also, but no issues found.

Can any one suggest what could be possible issue give a resolution.

Thanks in advance,

Nivas