DL180 G6 and ESXi 5.5

$
0
0

Hello!

 

I know that the latest supported version is "VMware ESXi 5.1.0 Update2 1483097 HP".

But I'm going to try installing "VMware ESXi 5.5 Installable HP Customized ISO Image" on DL180 G6 with HP P410/512 controller. Anybody done this? Are there any known isues or everything will work fine?

 

Thank you!


Problem installing SPP

$
0
0

I have a ML350e Gen 8 Server with SBS2011, which has several drivers missing, I was advised to download and apply Spp2014.

 

I have downloaded SPP 2014 and created the DVD

 

I Launch Start.htm

I select the language

 

I'm them prompted to accept the eula then run \hp\softwarepackages\hpsum.bat

 

but I have fallen at the first hurdle and I can'tsee anywhere to accept the eula?

 

I have viewed the first startup page and all of the eula but nothing?

 

I live in hope!

 

HP ProLiant DL580 G5 Noise Issue

$
0
0

Hi there, I am wondering if there are any other fans or software related ways to significantly reduce server fan noise. Right now I have the 6 default fans that come with the machine. They are extremely loud and are running at about 35-40% speed.

 

I'm hoping for some quieter fans or something. I'm ovbiously not having ANY issues with system temp.

Replace the Hot Spare that Shared between Raid 1 and raid 5

$
0
0

I have ProLiant ML370 G6  with Smart Array P410i Controller on System Board 

I have two Logical Drive (Logical Drive 1 - Mirroring (RAID 1) And (Logical Drive 2 - Distributed Data Guarding (RAID 5)

The logical Drive 1- Mirroring (RAID 1) Have two Physical Drives 

The Logical Drive 2 Distributed Data Guarding (RAID 5 Have three Physical Drives

And There Are One Spare Drive Shared btween RAID 1 and Raid 5 

Controller Configuration Summary
2 Data Array(s)
2 Data Logical Drive(s)
5 Data Drive(s)
1 Spare Drive(s)

The problem :

there are that the spare Drive FAil and have warining To replace it 

I  replace this drive with new one but the repulid for the Drive not start and Give Inactive 

How Repulid the Hot Spare drive  ?

SAS 2.5 to SATA

$
0
0

I need to know if the HP part number 654540-001can be used in a proliant ml310egen8v2 server already configured with sata non-hot plug HDD. I want to adapt the part number 654540-001 to a SAS HDD 146GB 10K. Hp model : DG146BB976. Hp P/N : 430165-003. Firmware : HPDC. Part number: 9F6066-035. Can It be functionable ?.

 

P.S. This thread has been moved from Storage Area Networks (SAN) (Small and Medium Business)
to ProLiant Servers (ML,DL,SL). -HP Forum Moderator

New SPP 2014.06 iso missing something?

$
0
0

Hi all:

 

I downloaded the latest SPP (2014.06). I was going to update drivers on-line and can't find the HPSUM.bat file.

 

Am I missing something or is the .iso?

 

Regards,

 

Louis

 

P.S. This thread has been moved from Servers>General to ProLiant Servers (ML,DL,SL). -HP Forum Moderator

Convert RAID 1 to RAID 5

$
0
0

Hi

 

Is it possible to convert RAID 1 to RAID 5 without loosing data,OS, and partition on RAID 1 drives while converting to RAID 5?

 

Server: DL360 G5

Current config: 2 x 146 HD RAID 1 with 2 partition

 

Additional Drives: 4 x 146 drives

 

SMH NIC box

$
0
0

Hi All

 

 I've installed SPP(2013/07) 

 

I have a problem that SMH(System Management Homepage) doesn't appear NIC box  in the system status box

 

Another system status box is appeared OK.

 

I don't know why it doesn't appear only NIC box

 

I've alredy installed SNMP & configuration.

 

I've checked SNMP Service  startup type(auto)

 

 

 

 

 

 


4 Proliant DL380 G6s in Cluster for vCenter, Can I install graphics card in one?

$
0
0

Like the title says I have 4 DL380s in a cluster running VmWare. I want to install a decent graphics card for a virtual CAD workstation that will be accessed by only one user at a time.

Can I get a PCIx16 riser card, video card and install the card then alot the resources to a single virtual machine?

Has anyone done anything like this before?

Thanks in advance!

Monitoring DL580 G5 using PRTG

$
0
0

Hello everybody,

 

i am trying to monitor a DL580 G5 using PRTG Network Monitor. So far everything is fine. I can monitor the server using SNMP Sensor "HP Proliant System State" and getting status of PSU, temperature etc.

But when it comes to the raid controller (P400) i am getting problems reading raid / drive / volume status. I already have installed WBEM provider (9.5.0.0) and management agent (9.40.12.0).

PRTG support says the required OID / OID branch 1.3.6.1.4.1.232.3.2.5.1.1.6.2 is missing.

 

Hope someone can help me out.

 

Thanks

 

Daniel

Implementing HP P200 G3 SAS MSA with 2nos HP DL380p Gen 8 servers

$
0
0

Hi all,

Can any one guide me to implent HP P2000 G3 SAS MSA with 2nos HP DL380p G8 servers with mutipath support. In a step by step manner.

 

Both servers should share the common data on the storage. If one servers goes down, then the other server should take over it

Raid and other hard drives not in Raid (HP E200i Ml350 G5)

$
0
0

Hi we have a Raid 5 (HP E200i) in our ML350 G5 Server (4x146GB)  logigal drive C: is about 440.3 GB
The free space on the disk is getting low.

So is it possible to add a new drive not in the raid, only 1 more drive for unimportant data. and make it d:\
i read that the controller can handle up to 8 drives. But if you have a Raid, musst all drives be in this raid? Or can i have my existing Raid 5 with 4 drives. and additional 1 or more drives?

Integrated Lights Out 2 (ILO2) Drivers on a W2k8 x64 Server

$
0
0

Dear Community,

 

first of all,this would be my first post so dont be rude for any mistakes please.

 

I am currently searching for the Driver that goes with the "Integrated Lights Out 2.0 Interfaz IPMI"(Source:pcidatabase.com)

Because my ProLiant Dl380 G5 always shows an unknown device,even though i already installed your driver solution found on the Website.

 

I had 2 unknown devices before,after the installation of the driver package(which i obtained at the offical hp website of course) one of them was gone,but the other one still remains.

 

Here are the Hardware IDs listed in Windows: DEV:0x3302 VEN:0x103C

 

Thanks in Advance,

 

Hauke Harms

 

Kraftverkehr Verwaltungs GmbH & Co. KG

Need to replace a Smart Array P800 Controller

$
0
0

Hello, I have a failing P800 Controller in a Proliant DL320s G1 that I want to swap with a replacement. I have done some reading that replacing the controller shouldn't be an issue and that the array information is stored on the drives. I am just looking from confirmation that if I replace the controller with another P800, that I shouldn't lose any data just by swapping the controller.

 

Thanks,

ITJoe4357

server wants to boot from usb drive

$
0
0

hi i have an HP ProLiant ML310e Gen8 Server that tries to boot from an attached  USB backup drive instead of it's local hard drive. the usb drive does not show up in the BIOS boot order options so i can't demote it, looks like it gets initialized later in the boot process

the USB drive is a new replacement for one that has died, the old one did not have this problem

it means the server can't restart itself after UPS shutdown as someone has to unplug the USB for it to boot

anyone come across this problem/ found a way to force it to boot from hard drive?

thanks

rob


NC364T quad port nic drivers for Windows 2012 R2

$
0
0

Hi there

 

Are there Windows 2012 R2 drivers for the NC364T quad gig nic?

i can only find Windows 2008 R2 drivers

 

I have tried two different nc364T nics with the Windows 2008 R2 drivers installed on Windows 2012 R2 and even though they seem to connect, data doesn't flow, dont respond to ping, etc

 

have these nics been dropped?

 

cheers,

 

 

Need help installing additional Raid Controller on ML350 G5

$
0
0

I have the motherboard bundled E200 controller connected now and are thinking about extending the server with more drives via a P400 controller that i also have in my posession.

 

I also need an additional backplane and power for this new backplane i guess. How do i get power for this second backplane?

 

Can someone help me with steps to take to install additional P400 controller with cables, backplane etc. on an ML350 G5 or give other tips on how to attach at least two more sata disks to the server (shall be used as OS disks with Raid1) when the E200 controller already are full of storage disk.

Flashing Amber/Green

$
0
0
Dear All, Drive Status on my HP Proliant Server is flashing Amber Green. When i read the Error Description it says " The Drive is a Member of one or more logical Drives and predicts the Drive will Fail. Could you please guide me how can i Fix this issue?? Cybermate

Installation Server 2012R2 failed on Proliant DL360 G7

$
0
0

Hi all,

 

I try to install Server 2012 R2 on a DL360G7...

 

It is running smoothly until Installing Updates and Finalizing the install...

At that point, the installation is exited with the error message;

"Setup cannot continue due to a corrupted installation file. Contact the vendor of your Windows installation disc or your system administrator for assistance."

 

I can use the iso for installation of Server 2012R2 on other systems, so I doubt the iso file is the problem.

 

Anyone seen this error before, and more important, any suggestions to get this os installed on the server.

 

Regards,

Bart

ML350G4p w/Smart Array 641 install W2008x64 R2 fails at load drivers for mass storage

$
0
0

I have downloaded every piece of software I could find for this controller but none will install, even when detected as "works with this computer". Will server 2008 r2 run on this box or should I downgrade to 2003 /2003r2. I only want to create a storage unit for data

Viewing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>