Proliant ML330 - Smart Array 641 (drive failed)
Hi,I have a customer running a very old server (don't know the CPU, but it has only 64RAM and runs NT4 SP6a & Internet Explorer 2.0)Anyway, one of two SCSI drives has failed. It's a 9.1GB model,...
View ArticlePOST Error in ML 350 G4
1783-Slot 5 Arrary controller is in a lock up state due to hardware configuration failure.( Controller is disabled until this problem is resolved)
View ArticleProliant ML330 LC2 Raid Controller
I have an array of 3 physical drives as one logical drive and works fine.I am trying to add another SINGLE 36.7 physcial drive as a logical drive.ORCA has no problem with this. WinNT4.0 sees the new...
View ArticleML330 G# SCSI Hot swap cage upgrade
I have installed an upgrade 2 hot swap drive cage into an ML330 G3 but when it boots it reports an error - Poliant storage encountered a problem. Cooling fan malfunction detected. It then fails to find...
View Article380g5 cannot boot after install secure path4.0c
dear all,msa1500cs+380g5 with E200raid card+FCA2214HBAx2,4/8 fibre switch,i install secure path 4.0c on windows enterprise 2003 in serverDL380g5.....after intalling finished ,the windows cannot...
View ArticleProliant ML530 - Adding Storage - Best method?
I currently have 6 18.2 Ultra3 15K SCSI drives installed on a RAID5 in the first cage, Cage A.Cage B is blank, not used. Should I add 6 more 18.2 Ultra3 drives in Cage B? What are my other options? I'm...
View ArticlePerformance issues using PCI-X to PCI-express riser DL360 G4p
Here is my hardware: HP ProLiant DL360 G4p, Single 3.2GHz Xeon, 2GB2 x 750GB SATA 7200 Internal Drives. Single logical drives. (no RAID)64-bit/133 MHz PCI-X to PCI-Express conversion kitHP...
View ArticleDL160G5p
I downloaded the 64 bit driver for SAS drives and I get the error message txtsetup.oem cannot be found after selecting F6 to install.No such file exists on the download.Thanks, Ken
View ArticleFailed Drive in SA 642
Some help would be greatly appreciated.Here's the scenario:HP DL145 G2SA 642 + BBWC2x36GB (RAID 1)Running out of space on the drives so I:1. Removed one drive (1/2)2. Set to failed3. Inserted new...
View ArticleSmart Array 5300 Controller Warning
Hi,I have a Smart Array 5300 controller installed in a Proliant DL580 G2. I was receiving the following warnings in event log.Source : Storage AgentsEvent ID : 1024Description : Drive Array Accelerator...
View ArticleRAID 1 migration on HP Smart Array 6402/128 controllers
Hi, There,We are running MS SQL database on HP Proliant G4 380 With RAID 1 Configuration. Currently we have 2 set of RAID 1, One for OS drive and another for Database drive. The 2 HDD for database...
View ArticleProliant DL380 G2
Hello,1 year ago a had this server as a gift from a company with a few scsi hdd's. But a whole time it whent oke with this server. but now when i start up the server for mutiple times (installing new...
View Article1783 - Slot 3: Array Controller is in a lock-up state due to hardware...
I found a problem . On my DL360 , I just boot up my server , but when I want to config Smart Array 6i's raid function , but it have a error "1783 - Slot 3: Array Controller is in a lock-up state due to...
View ArticleSA5312 lost raid configuration
Hi,I have ML530 server with Smart Array 5312 card connected to 12 internal SCSI disk.Created 2 logical drive, first logical RAID 1 with 2 disks and second logical RAID 5 with 9 disks and 1...
View Article5i Array Extension taking it's time
So I have a DL380 G3 with a 5i array controller running Netware 6.5 SP6 in it the disks were configured as 4x 36.4 10K disks Raid 5 with online spare. Since I am now out of space I have booted into the...
View ArticleSingle drive failure causes logical RAID5 failure
Unfortunately server is not under service, so I thought I would post to see if there are any thoughts or suggestions.The question in short:Is it possible to convince/force an SA6400 to attempt to boot...
View ArticleDL380 Gen 9 drivers are not correctly installed
OS: Windows Server 2008 R2Server: DL380 Gen 9GPU: AMD FirePro R5000 Hi Everyone,We are having some difficulties in installing this AMD FirePro card in a DL380 Gen9 Server.(we also use this card in a...
View ArticleHP Proliant DL160 gen9 temperature control
we have a new HP server which has a build in temp. sensor and we would like to monitor that in some kind of dashboard? or even give warnings when temp. is above a certain level. How can we best do...
View ArticleQlogic 2562 on DL380 G5
Hi all,i installed a QLogic 2562 on DL380 G5 server and when the server start, it stops after recognized hba. Googleing i found this url...
View Article