proliant dl380 g1
further to my previous thread..can i safely remove the 9g drive and not replace a [blank caddy]or is it neccessary for the blank to be inserted..ps i do not have another blank caddy
View Articlenetwork bug leading to BSOD
Ā With the team TLB method set to Round-robin, connecting to the target server such as via SMB, BSODs the target server sometimes almost instantly, sometimes after transferring a very small amount of...
View ArticleHP MIO Silent Install
Has anyone used this feature, we are trying to silently install HP MPIO V1.2 on some DL385 servers connected to an MSA1000 with FC2214 HBA's but the installation carries on as if it were a manual...
View ArticleMoving arrays between servers...
Hi Guys,Have several servers I need to upgrade.. current config on all of them is DL380 G2 with 2 x 36Gb U3 disks in mirror for OS and 4 x 146Gb 10k U320 disks in Raid 5 for data.Want to upgrade the...
View ArticleDisk Expansion using 5300 Smart Array
Hi all,Have ML530 G1, running Windows 2000 SP4, using Installed Agents for Windows 2000/Server 2003 7.10.0.0 Array Configuration Utility 2.90.65.0 HP Array Configuration Utility 7.15.19.0 Have expanded...
View ArticleP812 Solaris ACU CLI No Controllers Detected
We have a DL180 G6 with a P812 running Nexenta (based on Solaris)Ā The stock cpqary3 driver which Solaris include detected the P812 fine and it's connected MSA70 storage shelf.Ā #Ā modinfo | grep cpqary3...
View ArticleMirrored Drives Puzzle
Dear All I'm currently experiencing an issue with my mirrored drives in a DL360 - I'm trying to recover a server that was once a DL380 but I don't have a spare DL380 so I've placed one of the mirrored...
View Article17xx-Controller in lock up State
I have two ProLiant DL380 G2 servers, and it appears the 5i controller cards on both are non-functional.One server gives me the 17xx-Controller in lock up State error message.The other server attempts...
View ArticleProliant DL580, Smart Array 5300 Controller Failure!
I am running Windows Server 2003 on a Proliant DL580. Yesterday, the system blue screened and when I went to restart it came up with this message, "1783-slot x Drive Array Controller Failure!"I shut it...
View Articleadding drives to 642 controller
Hello, I have a ML370 with three 72gb scsi drives in RAID5, and a 642 controller. Unfortunately, I'm running out of disk space. I would like to add a couple more (identical) drives and expand the array...
View ArticleMigration Raid
I have HP ML-370 G3 server included Smart Array 642.I have installed new 72GB drive. I want Drive migrate RAID 0 to RAID 0+1. I did the follw.Launch array configuration utilities 7.30 and I see the...
View ArticleLogical Drive Expantion and Linux (DL380)
Hi, i in the process of adding one more disc to a 3 disc raid5 Logical Drive on a pair of proliant servers (DL380 G3 & G4). I could expand the array with hpacucli without problems (the G3 is...
View ArticleDVD Support for ML330 G3
Hi all, I'm new here and was hoping to find out why my ML330 G3 won't recognize my DVD-ROM? It's an HP DVD-ROM from an ML150. I'm running the latest BIOS 09-01-05 D15 and have searched the drivers...
View ArticleProliant ML370 Won't Install Windows Server 2003
I have a used proliant ML370 with a compaq smart array 4200 installed and i keep running into problems, i had to replace the cd rom drive, download a smart start cd, and make a system f10 partition.i...
View ArticleUsing OBDR in ML110G3 with SATA-RAID-1
Dear all :I got a ML110G3 server which had a SATA RAID-1as storage-disks...I knew there is an ODBR by using USB TAPE for this server...but I saw that OBDR was booted as a SCSI-CD-ROM to do the restore...
View ArticleWhich SCSI controller for new ML370
I want to quote a new server (ML370G4), but am not sure what controller I need. My config will beRaid 1 on 2 HD for OSRaid 5 on 4 HD for Dataexternal SCSI tape backupI assume I need the "backplane kit"...
View ArticleSA 6400, changing failed disk with correct spare but different GPN causes...
In our Proliant ML 570 G2 with Smart Array 6400we had a failed disk.Changing the failed disk with the correct spare sent by hp support caused other disks to fail as well.We removed all the new failed...
View Articlestatus Ready for rebuild
helloIĆ¢ m a newbie, I have a Proliant DL380 G4 with Windows 2000 server, using the system management I saw that the Logical drives are in "Ready for rebuild" status, my question is how can I start the...
View ArticleHost with redundant controllers
Hi all.I'm looking for a HP solution (competition is Dell with PERC active/passive controllers technology) that could address the need of redundant controller paths with automatic failover.I've listed...
View ArticleAgain: Mixing SAS and SATA Devices on E200i (ML350 G5)
Hello,as the forums says two different things, let me ask again please.I want to buy an ML350 G5 with 2 SAS Drives included (SFF). Those will be in a raid1.I also want a SATA HDD and a SATA-Streamer...
View Article