Splitting a logical drive in RAID
There is a ProLiant 360 g6 server with P410i controller.8 x 1Tb hard drives are configured as RAID 1+0 into 1 logical drive (3,6Tb)Then it's was partitioned into 300gb+3300gb partitions during Windows...
View ArticleHP SUM 7.10 Erros
Hi, i'm having two inventory problems in HP SUM 7.10: 1. Nodes with any version of windows 2003 OS after inventory i get an error: " Unable to start hpsumservice engine on node %2.", when trying to...
View ArticleG7 DL165 board won't powerup
Hi there, I have a DL165 G7 board laying here and thougt it would be nice to build something out of it. I'm trying to power it up with only 1 processor and 1 bank of memory on a CORSAIR 750 Platinum...
View ArticleML115G5 BIOS - Softpaq SP44683.exe
Hi there I'm trying to get this old ML115G5 server up-and-running for a non-profit organisation as a test/dev setup running CentOS. I've never before encountered a company who insist upon a service...
View ArticleHP ProLiant Dl380 G3 Won't display, no POST, CR49 + Proc1&2 Amber - is it MOBO?
Hey guys. I recently got an old Proliant DL380 G2 server to mess with, but it won't boot. The display never lights up, and the error lights CR49, Proc1 and Proc2 lights, as well as an SVC light in one...
View ArticleIntermittent Network Connection
Good day. Just want to consult regarding the problem I encountered with my current set-up. I have HP Proliant DL360p Gen8 Server running on Windows Server 2008 R2. Everytime I connected the 4 Network...
View ArticleHP vibsdepot - release notes/versioning
hi all, Just wondering how I can get the release notes of vmware vibs made available by HP. Basically I am running vmware 5.5 on DL580G7 hosts and have recently successfully created a baseline to point...
View ArticleHP ProLiant DL160 G6 - x22 multiplier
Hello everybodyIs it possible to get the x22 multiplier on all cores with HT enabled on the HP ProLiant DL160 G6 with 2 x xeon5650 and 4x12GB ram ? Works only on 20 sometimes 20.5thanksMario
View ArticleML350G6 - Reduced acoustics not available with 4th fan
Hi. ML350 G6, 1 proc, latest FW's. Added a 4th fans, because "I can", maybe reduce the total noise, but keep the total airflow. In the bios the Reduced Acoustic option will not be saved with the 4th...
View ArticleDL 380 Gen8 with Windows Server 2012 R2 Hyper-V Role NICS change
Hello there, we have a DL 380 Gen 8 Server installed via provisioning. ILO and 1 NIC is connected.When we open the network center we see 4 NICs with naming 1 -4. NIC has static IP.As soon as we install...
View ArticleHP DL380 G5 update firmware error code 6
Hi expert,I used the HP Smart update firmware version 2014.2 to update server HP DL380 G5.and i get the error:Install:CP021848.scexeVersion:2.11.20CDescription: HP Broadcom Online Firmware...
View ArticleSmart Array P430 with amber light
I have P430 that would not post SAS Firmware during bootup. The Debug LED next to the SAS connector is amber in color. According to the user manual, on = Controller in reset state Heartbeat LED is...
View ArticleNew DL360 G5 iLO firmware missing from support pages
Hi, on the support page for DL360 G5 for RedHat 5 x86-64 but also for other OSes there is listed very old firmware for iLO, version 1.43 from Dec 2007. I know for sure that there were many new...
View Articlefirmware updation
Hai, I am ravikumar and i have a server model HP ProLiant DL180 G5 with Smart Array e200 with BBWC connected. When I go to console page of the server for a check it is showing an error as battery...
View ArticleInstall OS
Hi All:I want know if I can Install W2008 Server R2 in a Proliant DL360 G5 server (Quad-Core Intel Xeon E5420 2.50Ghz). ?Thanks for your help.
View ArticleDL180 G6 / SE326M1R2 : BIOS Update (05-05-2011 to actual)
Hello everyone, I just recieve a DL180 G6, I have correctly updated the ILO2, P410i... But the BIOS update doesn't work. At each time it says that there is no ROM to update on this product when I boot...
View ArticleP222 or P421 Smart Array (Gen8) in a new Gen9 Proliant Server?
Need to know if the P222 or P421 SmartArray (for Gen8 servers) will work in the new Gen9 servers? All that are listed in the Gen9 config guides are the new 12Gbps P240 and P441controllers, which are...
View ArticleInstalar disco duro SAS de 300 Gb en un HP proliant DL380 G5
¿Cómo puedo configurar un disco HP SAS de 300 GB con espejo en un servidor HP proliant DL380 G5? Gracias de antemano P.S. This thread has been moved from Disk to ProLiant Servers (ML,DL,SL). Also, we...
View ArticleAdding more storage and memory to a Proliant DL380p Gen8 Server
Hello forumI have a Proliant DL380p Gen8 server with 2 10K SAS 300GB SFF disks. The system is configured as RAID 1 and has 32GB of RAM.The server is fronted with ESXi 5.0 and there is only 1 VM running...
View ArticleSE326M1 PCIe bandwidth
I'm currently looking to acquire a few SE326M1 Motherboards with X5650s for scientific crunching purposes. I would like to add pairs of GPUs to them in the near future and wanted to find out what...
View Article