No 32 bit drivers for Gen 9 Proliant server
Hello,I am wondering why there are no 32 bit drivers available for Gen 9 Proliants like the DL380 Gen 9. We would like to use RHEL 6 32 bit because of a 3rd party limitation but this doesn't seem to...
View ArticleHP DL160 Gen8-Doesnt detect Drives (B1i20 and P222)
Hi All I really need help. I have a new HP DL160 Gen8. I have 4 HP 1TB SAS DrivesI also purchases an HP P222 I installed the HP P222 , made sure the cable from the HP P222 is connected and the on board...
View ArticleTotal processing power of Proliant DL 380 G3 with fedora 20 - X86 - 2...
Good evening. I've installed, with "redundante" configuration, of two 3,06 intel Xeon processors. Fully redundant with two PSU. I'll try put this server on folding at home. I'm using RAID 0 array....
View ArticleHot Swapping Hard Drives in ProLiant Servers
I actually was just wondering, when you are hot swapping a hard drive in a G7/G8 ProLiant server, does the replacement hard drive have to be one with a matching spare part number? Or can you use one...
View ArticleDL360 G8 with Dynamic Smart Array B120i RAID with Microsoft Windows 2012 R2...
Hi, Can anyone assist - we have installed an HP DL360 G8 server and Dyanmic Smart Array B120i RAID with Microsoft Windows 2012, but we are unable to install Microsoft Windows 2012 R2. Can anyone...
View ArticleInstalling Windows 2012 R2 on ProLiant DL180 G6
I have two ProLiant DL180 G6 that I am trying to upgrade from Windows 2008 R2 SP1 to Windows 2012 R2. I was successfully able to install it on one server, but on the other server, Windows 2012 did not...
View Articleillegal opcode HP SL4540
Hi all, I'm trying to install an ubuntu sytem on SL4540 HP hardware and i got an error message like "illegal opcode" with a red screen. I configured an ilo adress,i'm connected to create a Raid1 and...
View ArticleHP Service Pack for ProLiant (SPP)
Does each successive HP Service Pack for ProLiant (SPP) release incorporate all of the updates from the previous release, and more importantly do they include the supplemental releases of the previous...
View ArticleHELP HP PROLIANT GEN8 WITH WINDOWS SERVER 2012 R2 UPDATE
Hi everyone. I have a HP-server Proliant DL308p Gen8, OS windows server 2012 r2 standard. then I update windows, error is: Can you help. thanks all.
View ArticleBay 3 phycial drive has failed and bay 7 indicator light says not to eject
hi Guys SAS drive on bay 3 my RAID 1+0 has faied on HP ProLiant DL360p Gen8 server. I have organized replacement drive with HP and due by tomorrow Also I see in Bay 7 inidcator light says not to eject...
View ArticleGetting full processing power of Proliant DL 380 G3 with Linux fedora 20 -...
Good evening. I've installed, with "redundante" configuration, of two 3,06 intel Xeon processors. Fully redundant with two PSU. I'll try put this server on folding at home. I'm using RAID 0 array....
View ArticleDL380 G5 increase size of a RAID 5 array
We have a DL380 G5 with a RAID 5 array. It has 8 72GB 15K discs with a P400 controller. The end users have asked for the array size to be increased with larger drives. Is it the case that -if the...
View ArticleHP Smart Array P222 - Can't find harddrives
Hello, hopefully somebody can help me with my problem.My configuration looks like follows: ProLiant MicroServer Gen8HP Smart Array P222Raid 5 including 3x harddrives I wanted to upgrade the CPU and...
View ArticleHP ML110 G5 gets no client connection after BIOS battery change
Hi everybody, quite a silly question, but still putting it (though I know that there may be an oodleplex of possibilities): I had to change the BIOS battery on an ML110 G5. To do so, I disconnected it...
View ArticleHp Proliant DL380 G7. Questions about Hyperv/iLo3
hi all, i have two hp proliant dl 380 g7 server.both are under windows server 2008 hyper-v (minimal version - non graphic)ilo version is 3 (ilo3_180)CD/DVD i have doesn't work anymore (it always launch...
View ArticleProliant dl380 (G6) BIOS Upgrade
Hello to everyone, i need to do a flash upgrade of the bios of the proliant but when i try to go into the support webpage it fails always...
View ArticleProLiant ML350 G5 shutdown irregularly
ProLiant ML350 G5 This server's redundant power supply was failed and won't plan to replace it. The other power supply is still running. Recently, this server is shutdown irregularly without any...
View ArticleDL580G7 - Naming of internal disks
Hello All,I have a ProLiant DF580G7 with 4 internal disks (as SMH reports). (I have never seen one in real life.)I received an error message by email, noting that "Physical Drive Status Change: Slot 0...
View ArticleBus expander in wrong slot, system halted. Required slot not available.
So I am useing my old ML370G5 for different purposes now it is becoming outdated. (Brief history, question below)I bought a graphics card and using a dremel reduced the pci-e slot size from 16x to 8x,...
View ArticleReuse RAID5 disk on same controller removed from.
I haven't seen this variation discussed.Have taken out a disk predicted to fail and replaced it with a new one and the RAID5 array is running normally again.Can I put the original disk in a spare slot...
View Article