ProLiant ML350: unexpected freeze and reboot

$
0
0

Hi all,

I'm having trouble with a HP Proliant ML350 G5 just formatted and unexpected reboot.

 

The configuration is the default with only two new 1TB disks bought from HP seven monthes ago and added in a secondary RAID 1 configuration for the data in addition to a RAID1 of two 256GB HD for the OS.

 

I've noticed the reboot in this occasions:

 

1. Moving a big ISO file from the NAS to the server in the secondary RAID1

2. Windows Update synchronization

3. Windows Update installation

 

Moreover sometimes the system freeze completely.

 

I've tested the system with software like SuperPI, Prime 95, HeavyLoad for hours monitoring the temperatures and no reboots has never occured.

 

In the iLO 2 Log I see "Server reset" / "Server power restored" or "Server power removed" / "Server power restored" entries.

 

In the IML section the last log is from five monthes ago (I attach a screen shot of the logs).

 

What could be the cause of this reboot and freeze?

 

What are the tools I can use to test the whole system to obtain a definitely response?

 

Thank you.

 


ml350 g5 drive configeration

$
0
0

Does anyone know how to get the largest hard drive capacity with the e200i raid ? will 6x2tb work ?

Any advice would be great, thanks heaps.

which model / type support SAS FRU 6Gb SAS

$
0
0

hello all,

 

I intend to use HP servers,

which server model/type support with SAS FRU 3.5'' HDD 6Gb SAS?

because i have more HDD 2TB SAS FRU not used in the office and i want to use it for new server.

if you dont mind, please give me some info, what model/type HP server i can use for this HDD?

 

Thank you

 

Regards

Dedi

SBS2001 on DL380P Gen 8 HP intelligent provisioning Required driver cant be installed

$
0
0

SBS2011 DL380P GEN 8

Using  HP Intelligent Provisioning
Gets to step 2  in Windows install
then stops with Windows

 

 Installation can not continue because a required driver could not be installed

We have updated Intelligent Provisioning to the latest version for server

 

Ran it up using  the ISO on a USB stick, on a CD and via external CD


Intelligent Provisioning  found the ISO  on the stick as a source, ran the install and failed.

 

 

inquery

$
0
0
Dear sir/madam

could kindly let me know what are the more advantages it has in intel i3 cpu than intel core 2 duo and DDR2 and DDR3

Proliant DL360e Gen8

$
0
0

Dear all,

 

a customer is reporting the Proliant DL360e Gen8 installed at the office, is experiencing high fan speed rotation, without a specific reason (CPU utilization is low, and room's temperature under control). Probably the fan reported is the PSU one.

Because the server room is not usually guarded, they can not say how many times does the event occur an a day.

So, accessing to iLO or other places, is possible to get a Log of temperature or fan rotation speed?

 

Thanks in advance.

Lorenz

H241 with Netapp E-2700

$
0
0

Hello,

 

we have got a HP H241 HBA in a DL360 Gen9 connected through HD SAS to a Netapp E-2700.

On the Netapp E-2700 we created several volumes and the H241 only sees the first one "LUN 0".

If we change another volume to LUN 0, the H241 sees only that one.

 

So whatever we try to do, the H241 always only sees LUN 0 and none of the other volumes.

 

Could someone please help us with this issue?

Newest firmware applied on both devices.

 

Best Regards

Betterbits

Replace DL380 RAID 5 drive with a drive from another DL380 RAID 5 server

$
0
0

I have a failing drive that needs to replaced. I have 2 DL380's with a RAID 5 configuration. Both have the same hard drive model numbers. Both servers were in use and have an OS installed.

 

Can I pull a drive from the DL380 I am not using and swap it with the failing drive in the DL380 I am using?


How to replace failed drive in RAID 50 array in HP DL380 G7

$
0
0

Hello,
I have a HP DL380 G7 with 8 drives of 300 BG. A RAID 50 is configure on it and one drive has failed. I want to replace that drive. I tried to do that by removing the bad one and just adding the new and put on the server. But the server doesn't load the OS at all. And when I do a rollback, the server can start normaly, while led of the disk in blinking to the red. 

 

Please, could someone help me?

 

 

P.S. This thread has been moved from Disk Array to ProLiant Servers (ML,DL,SL). - Hp Forum Moderator

Hp proliant DL480G5 power issue

$
0
0

 

I have two servers HP proliant DL580G5 , one of them shuts down suddenly after

- almost one hour for the first time .

- 5 minutes for the other times .

 

the Event log say this :

hpqilo2 , power supply 2 has failed

- The UPS is now on maintainance and the server runs directly on the power of a local power generator

Any thing I can check or maintain to fix this ?

 

 

DL120G5 Easy cd set up Smart Start?

$
0
0

We have a DL120G5 server that needs to be upgraded to at least to Windows 2008R2 to get the Exec back up to work for our Exchange server 2010.  We don't have cd or iso for this server all the smart start we have downloaded comes back with

"Unsupported Model - installation not available".  Is it possible someone can provide me with the correct version of either smart start or easy cd setup for DL120G5 server. Or provide some sort of way I can get Windows server 2008R2 on there.

HP Smart Array P440ar in HBA mode

$
0
0

Hello,

 

I have an issue with HP proliant 360 Gen9 with HP Smart Array P440ar in HBA mode.

Server has 8 X 900 GB sas drives installed. Server works in BIOS legacy mode.

 

I'am trying to install centos 7. Centos7 installation only detects 1 HDD, other 7 are missig (same with centos 6.5).

HP Smart Storage Administrator (HPSSA) shows all 8 drives.  

 

What do I need to do in order to resolve this issue?

Firmware Update CD

$
0
0

What has replaced the Firmware Update CDs?? Do use a SmartStart disk?

on controller i/o failed for 28. i/o being retried via raid path for lun

$
0
0

DL380p Gen8  

 


in the windows system log was found below message ,have any idea?  i think may install ssd issue?

on controlle(bus2,device0,function0) i/o failed for 28. i/o being retried via raid path for lun(0,1,1)

we have upgrade P420i controller firmware .and hpcisss3 drivers.

 

 

P.S. This thread has been moevd from General  to ProLiant Servers (ML,DL,SL). - Hp Forum Moderator

BSOD 0x00000124 and critical error on iLO log for Voltage CPU Vterm

$
0
0


Voltage CPU Vterm Lower Critical 1.1466 Volts

Generic 02/06/2015 08:25:18 CPU Vterm Lower Critical-going low Deassertion
Generic 02/06/2015 08:25:21 CPU Vterm Lower Critical-going low Assertion
Generic 02/06/2015 08:25:22 CPU Vterm Lower Critical-going low Deassertion
Generic 02/06/2015 08:25:25 CPU Vterm Lower Critical-going low Assertion

Generic 02/06/2015 08:27:08 CPU Vterm Upper Critical-going high Assertion
Generic 02/06/2015 08:27:09 CPU Vterm Upper Critical-going high Deassertion

 

Voltage CPU Vterm Normal operating range 1.1564 Volts


Voltage CPU Vterm Normal operating range 1.2446 Volts


Voltage CPU Vterm Lower Critical 1.1172 Volts

 

HP ProLiant ML110G4 keeps rebooting from time to time due to bug check code 0x00000124 BSOD

 

Any idea?

 


HP ML310e ProLiant v2 Gen8 + Универсальное аудио устройство USB

$
0
0

К серверу HP ML310e ProLiant v2 Gen8подключил аудио устройство USB - работает программа сигнализации объектов, встроенного аудио на материнке нет. Универсальное аудио устройство USB - из USB наушников, наушники отрезаны и перепаяно на настольные динамики.

Всякий раз после "Завершения работы" или "Перезагрузки" сервера значёк "Динамики" на панели задач перечёркнут красным крестиком и звук не работает, хотя в "Диспетчере устройств" в пункте "Звуковые и аудио... устройства" - "Аудио устройство USB" - "Состояние устройства" пишет что "Устройство работает нормально".

Чтобы звук заработал нада каждый раз заходить в "Диспетчер устройств" нажимать "Удалить устройство" потом "Обновить конфигурацию оборудования".

Но простому дежурному персоналу это сделать очень тяжело, они вызывают "компьютерщика" в 3 часа ночи...

Как решить эту проблему, кроме как купить PCI звуковую карту? а может и она так будет работать?

HP ProLiant SE servers

$
0
0

Hi all,

 

there are quite a number of 2nd hand HP ProLiant SE servers available at resellers. Given the prices and and specs I currently feel they are the most interesting offer for my needs.

 

I am slightly concerned however that the HP support side does not mentioned that product at all. Searching the forum I realize they are "custom build" (even though maybe at a very large scale) servers for specific datacentre clients.

 

Also I read that they are "similar" / "same" as DL servers.

 

Will DL drivers (Windows Server 2008) work on those?

Is there a chance to register with HP to get support? - Whereas that to me would not really mean anything more than getting access to the correct drivers for Windows Server versions.

 

Many thanks upfront for your insights!

Oliver

B320i controller: Side effects of enabling physical drive write cache state

$
0
0

I have an HP ProLiant DL360e (G8) with B320i controller. I want to enable physical drive write cache state.   It seems easy to do this from the HP Smart Storage Administrator | Modify Controller Settings.  My two questions are about the side effects.
1)  Does this force a rebuild of the drive array?  Cannot live with this!
2)  Does it require a reboot?

ILO V2 using CLI to mount and boot from HTTP ISO

$
0
0

I am trying to mount and boot from a Red Hat ISO that I have put on a web server.  Because I am working remotely in a secured environment I do no have web interface access to the ILO only command line.  So  here is what I have:

 

</>hpiLO-> oemhp_ping /map1 *.*.*.199
status=0
status_tag=COMMAND COMPLETED

 

</>hpiLO-> set /map1/oemhp_vm1/cddr1 oemhp_image=http://*.*.*.199/var/www/html/rhel-server-6.6-x86_64-dvd.iso
status=0
status_tag=COMMAND COMPLETED

 

</>hpiLO-> show /map1/oemhp_vm1/cddr1 -a
status=0
status_tag=COMMAND COMPLETED


/map1/oemhp_vm1/cddr1
Targets
Properties
oemhp_image=http://*.*.*.199/var/www/html/rhel-server-6.6-x86_64-dvd.iso
oemhp_connect=No
oemhp_boot=No_Boot
oemhp_wp=Yes
oemhp_applet_connected=No
Verbs
cd version exit show set

 

</>hpiLO-> set /map1/oemhp_vm1/cddr1 oemhp_boot=Once
status=0
status_tag=COMMAND COMPLETED

 

</>hpiLO-> show /map1/oemhp_vm1/cddr1
status=0
status_tag=COMMAND COMPLETED


/map1/oemhp_vm1/cddr1
Targets
Properties
oemhp_image=http://*.*.*.199/var/www/html/rhel-server-6.6-x86_64-dvd.iso
oemhp_connect=No
oemhp_boot=Once
oemhp_wp=Yes
oemhp_applet_connected=No
Verbs
cd version exit show set

 

</>hpiLO-> show /system1/bootconfig1/bootsource1 -a
status=0
status_tag=COMMAND COMPLETED


/system1/bootconfig1/bootsource1
Targets
Properties
bootorder=1
Verbs
cd version exit show set

 

So, when I do a "reset hard" the system goes through a bootup, but it boots to the already installed OS on the hard drive, not from the ISO that I'm trying to use to install a new OS.

 

Any idea what I'm doing wrong here?  Please excuse the obscured IPs, but again, it's a secure environment and I'm not supposed to let those get out.  They do match.

Convert existing 2-disk Raid 1 to 4-disk Raid 1+0 in ONLINE mode

$
0
0

Hello,

I have a Proliant DL380p Gen8, currently with 2 disks configured as a Raid 1. I run the HP-supplied-image of Vmware 5.5U1 on the server. I just purchased 2 more SAS drives of the same size as the existing disks (4TB each). I have a P420i controller with firmware 5.42. I would like to:

1. Convert the existing 4TB Raid1 logical drive to an 8TB Raid 1+0 logical drive without losing my existing data. Can this be done?
2. As this will take some time to do, I would like to do with the virtuals machines still running. This means using hpssacli on the ESXi 5.5U1 host. Can some give me the exact sequence of hpssacli commands for this procedure?
3. Expand the VMFS5 datastore. This part is a VMware question, not an SSA question, but I mentioned it in case anyone has insight to this step as well.

 

Regards,

Jeff