Before update:
I recently installed 2 new Compaq 72GB 10k drives. They worked perfectly for 2 months without any errors until 2 weeks ago.
We just recently recieved 2 Maxtor 147GB 10k drives and those were installed in this week. The are formated but not being used until this matter is resolved.
I moved the page file to a new location off the C drive. Which in turn stripped about 2 mintues off of our boot time niceee. I removed the Tape backup and it no longer exists. Anyone want to buy an HP DAT 40x6?
Update:
Ran HP Smart Start 7.10 Boot CD and aeverythign passed with flying colors.. RRRRrr
Ran HP Firmware Boot CD and all firmware was up to date! pat on my back
Bought a new cable kit from HP!
New point to point scsi cable was replaced. Rebooted and got this.
I get one of these:
Source: adpu160
ID: 11
A parity error was detected on \Device\Scsi\adpu160m2
I get 3 of these:
Source: adpu160
ID: 9
The device, \Device\Scsi\adpu160m2, did not respond within the timeout period.
I get 24 of these:
Source: adpu160
ID: 5
A parity error was detected on \Device\Scsi\adpu160m2.
I get 35 of these:
Source Disk
ID: 51
An error was detected on device \Device\Harddisk1 during a paging operation. <---Mostly these show up.. 7 to 1 ratio
An error was detected on device \Device\Harddisk2 during a paging operation.
An error was detected on device \Device\Harddisk3 during a paging operation.
An error was detected on device \Device\Harddisk4 during a paging operation.
An error was detected on device \Device\Harddisk5 during a paging operation.
Controler?? Means mobo replacement since this is built on.
New controller? what happens to all the drives will everything be eaxctly like it is was with a new controller installed? Security, drive letters OS, the works, I have never done it this way before! Would everything have to be reconfigured? Remember everything is in a Hot bay with a simplex board!
I'm thinking to order a new mobo and test it next.
So what do you all think????? dynomite sounds good!