Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

Proliant ML350 G6 Pinout Request

$
0
0

Hi everyone,

I'm hoping someone can help me with my request, I'm looking for the pinout for the two System Power Connectors on the top-right edge of the Proliant ML350 G6 motherboard (See Picture). If you own this server but don't know the pinout, I should be able to use detailed pictures of the color order of the connectors to determine the volatages. Thank you for any help!


HP System Managment HomePage timeout error

$
0
0

Hi every one,

I am new in HP community and first time using this community for my quries.

I have HP DL380p Gen8 on which i installed Windows Server 2012R2 , i install HP System Managment but it when i click on  HP System Managment HomePage and provide my login id and password after that the response time is very very slow and also pop up some SNMP related error however my i reset in to default setting of SNMP but still error occurs

 

A timeout occured while loading data for the HP System Managment HomePage which may result in missing or incomplete information.Please ensure that the various agents configuration is correct.One common error is around setting SNMP community strings and having at least one read/write string specified.for additional information on how to discover which components may be causing the timeout , see the HP system Management homepage log and the HP system Management user guide troubleshooting section.

Error During Configuring iLO

$
0
0

I have HP Proliant DL380 Gen8 and wanted to configure iLO so i just downloaded iLo utility from HP Site and install but when i try to configure iLO i got two errors.

can some please help

Scee Attached Screen Shot Files.

 

DL380 Gen9 Smart Array P840 can't move disk drive from a server to an other

$
0
0

Hello

Why i can't move disk drive from a server to an other ?

i try both method as explained in the SA user guide : Manuel and split mirror.

the new server doent see a valide LUN on the splited disk.

 

Thank you

dl380G6 System Interrupt Controller can't find drivers

$
0
0

Hello 

I cant find drivers for this devices (3 same devices) System Interrupt Controller for win2k8r2

Hardware ids : PCI\VEN_8086&DEV_3422&SUBSYS_000B003C&REV_13 

Thank you

DL380e g8 with Smatrt Array P420 SSD compatible not matching?

$
0
0

Hello guys,

I've read quickspecs of Dl380e G8 : http://www8.hp.com/h20195/v2/GetPDF.aspx/c04128166.pdf

it contains  SATA 2.5in MU-PLP SC SSD (804613-B21)  as compatible for server but when I read also quickspecs of Smart Array P420 :

http://www8.hp.com/h20195/v2/GetPDF.aspx%2Fc04111534.pdf

it does not show SSD above as compatible. My doubt  is that Smart array specs are oldest (doc released 2014) and maybe did not include all recent ssd as compatibilty ?

How you suggest to proceed ?

thanks for any advice

Andrea

HP Proliant ML150G6 Flashing BMC SDR/CONFIG....... Please wait.

$
0
0

Good afternoon.
Updating the firmware HP Proliant ML150 G6 cp024879.exe

Unsuccessfully, after the launch here this inscription:

 

The system only has generic SDR? system will REBOOT after update default SDR!!! 
Flashing BMC SDR/CONFIG....... Please wait. 
DO NOT power cycle or reset the system? may take several minutes.....

 

The message shown on the screen is very buzzing fans, after 7 minutes the server reboots. I waited for 45 minutes, it rebooted 5 times. Nothing changed.

 

How to fix?

 

dl380G6 System Interrupt Controller can't find drivers

$
0
0

Hello 

I cant find drivers for this devices (3 same devices) System Interrupt Controller for Win2k8r2

Hardware ids : PCI\VEN_8086&DEV_3422&SUBSYS_000B003C&REV_13

Thank you


What's the order of DL360e Gen8 4 NICs.

$
0
0

Greeting.

I am looking for the order of DL360e Gen8 NICs, there are 4 NIC on it.

which NIC port is the 1st? beginning with left or right? thanks.

Number 5 pointed is 4 NICs.

DL360eG8.jpg

DL380 g6 ILO2 with discrete's video card

$
0
0

Hello

The question is, can i use ILO2 with discrete video card? 

Now i see only grey display over web ..

over putty ssh wrote integrated video card is disabled ... 

Thank

BL460c G7 - Windows Server 2012 - NC553i Dual Port Flex Fabric 10Gb not working

$
0
0

I have a BL460c G7 that I am trying to repurpose as a test server. I have deployed Windows Server 2012 R2 and pushed the HP SPP 2015.10 but the NICs still will not show up in network connections. 

Is there a seperate Emulex driver that anyone knows of that I can install to resolve this issue?

I am getting the following error code:

"This device cannot start. (Code 10)

{Operation Failed}

The requested operation was unsuccessful"

 

Server: HP BL460c G7

HP SPP version: 2015.10

OS: Windows Server 2012 R2

NIC: HP NC553i Dual Port FLexFabric 10Gb Converged Network Adapter

Driver Version: 10.5.121.7

 

 

Thanks,

Tony

Power Supply for Proliant DL380 G6 from DC to AC

$
0
0

 The question is simple.  I have two HP Proliant DL380G6 servers with a DC Power Supply. 

Currently I have two:

  • 437573-B21 – HP 1200W -48V DC Common Slot Power Supply

 

Can I just swap that out with one of these AC PART Number:

  • 503296-B21 – HP 460 W HE 12 V Hot Plug AC Power Supply Kit
  • 512327-B21 - HP 750W Common Slot High Efficiency Power Supply Kit
  • 500172-B21 – HP 1200W 12V Hot Plug AC Power Supply
  • 578322-B21 – HP 1200W Common Slot High Efficiency Power Supply Kit

 

We are putting into a HP Rack system which I believe is 220.

 

Online Expand RAID 6 HP P410i Controller

$
0
0

Hi HP experts,

My DL380 G7 using HP P410i 512 MB Memory + Battery and license Smart Array Advance Pack 1

I have 3 Array :

  1. 2 x 146 GB ( RAID 1 ) for Operating System
  2. 6 x 600GB (RAID 50) for Data
  3. 8 x 600GB (RAID 6)For Data

I would like to expand the RAID 6 Array and extend the logical drive in this array, i  am considering delete RAID50 Array and add 6 free disks to RAID6 Array. ( Please open the attachment for detail Hardware and software )

 Does my Hardware and software support me to expand RAID6 array and its logical drive without losing data ?

Can i expand array online?

Thank you so much

scsi ultra 320 adapter lsi22320bcs-hp

$
0
0

Is there drivers for the lsi22320bcs-HP scsi ultra 320 for windows xp and windows 2003server?

Thanking you in advance

Abavis Stavros

Naval Architect and Marine Engineer NTUA99

 

Failed drive but only the volume shows errors

$
0
0

In my DL380 Gen9 with P440ar raid controller, one of the mirrors has failed.  The volume says it is queued for rebuilding, but the rebuild never starts.  The raid config utility says the drive is fine. There are no error lights on the drive, and activity seems to be occurring.

However, the other drive in the mirror is showing the 'do not remove' light, implying the mirror is broken and only it is operating.

I ran dignostics, and they say 

Internal Storage Enclosure Device Failure (Bay 3, Box 3, Port 1I, Slot 0)

Device, Test: Logical Drive 1, Storage Controller in Slot 0 Failed Count: 1 Error Code: F154
Description:
The monitor and performance logs indicate an aborted command failure.
Count: 1
Recommended Repair:
If single drive has ABORTED Command - Re-Seat and monitor. If all drives, then check backplane or cable or Controller.
Device, Test: Logical Drive 1, Storage Controller in Slot 0 Failed Count: 1 Error Code: F297
Description:
Logical Drive status is outside of normal operating parameters.

Recommended Repair:
Refer to the HP Smart Array Controller User Guide for a detailed description of the logical drive state and troubleshooting procedures. The User Guide is available from hp.com.

Last Failure Reason ABORTED COMMAND

Write Errors Retry Recovered 1

Aborted Command Failures 1

 

So my main question is, how come with all these drive errors, the raid config utility says it's ok, and there are no error lights on the drive?

Secondly, is the best course of action just to replace the drive with a spare and hope it rebuilds ?

 

Thanks


ML150 G9 w/ H240 HBA can't boot from HDD

$
0
0

Hi!

I'm struggling to get my new ML150 G9 to boot from the hard drive. I managed to install CentOS 7.1 without much trouble both in Legacy BIOS and UEFI mode but then after I reboot it claims there are no bootable drives. I have only the single drive connected. I tried unplugging all USB devices, no luck.

The machine has H240 controller (*not* B140i which seems more common) and it's set to HBA mode. When I enter the SSA tool the disk is set as uninitialized but I guess that's normal for non-RAID configuration.

The Intelligent Provisioning tool sounds like a fine idea but CentOS doesn't seem supported.

Server cannot boot after firmware update with P212

$
0
0

I`ve just installed a perfect-running Smart Array P212 in my server. It comes with 2.72 firmware version.

My server runs vmware ESXi 6.0 and, after perform a firmware update to 6.64 version from this link: https://h20565.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=3885794&swLangOid=8&swEnvOid=4115

I perform the installation process correctly, bur after it the system asks to perform a reboot. I went out from esxi shell and reboot the server.

But after it the system shows the message:

HP Smart Array P212 Controller      Initializing...   +x+ 

(the rotation mark)

And then it halts. Don`t proceed with the booting process.

I am desperate, because we have some important data in the raid disks.

 

Please someone help me what can I do to bring the board back to work, please.

smart array 420i not detect my samsung ssd disk

$
0
0

hi

 

my server is hp dl 380G8  and my smart array contoler is p420i with latest firmware : 

these are all of my smart rray controler info :

 

Smart Array P420i in Slot 0 (Embedded)
   Bus Interface: PCI
   Slot: 0
   Serial Number: 0014380279DE940
   Cache Serial Number: PBKUD0BRH4Y2GU
   RAID 6 (ADG) Status: Enabled
   Controller Status: OK
   Hardware Revision: B
   Firmware Version: 6.68
   Rebuild Priority: Low
   Expand Priority: High
   Surface Scan Delay: 15 secs
   Surface Scan Mode: Idle
   Queue Depth: Automatic
   Monitor and Performance Delay: 60  min
   Elevator Sort: Enabled
   Degraded Performance Optimization: Disabled
   Inconsistency Repair Policy: Disabled
   Wait for Cache Room: Disabled
   Surface Analysis Inconsistency Notification: Disabled
   Post Prompt Timeout: 0 secs
   Cache Board Present: True
   Cache Status: OK
   Cache Ratio: 10% Read / 90% Write
   Drive Write Cache: Enabled
   Total Cache Size: 2.0 GB
   Total Cache Memory Available: 1.8 GB
   No-Battery Write Cache: Enabled
   SSD Caching RAID5 WriteBack Enabled: False
   SSD Caching Version: 1
   Cache Backup Power Source: Capacitors
   Battery/Capacitor Count: 1
   Battery/Capacitor Status: OK
   SATA NCQ Supported: True
   Spare Activation Mode: Activate on physical drive failure (default)
   Controller Temperature (C): 61
   Number of Ports: 2 Internal only
   Encryption Supported: False
   Driver Name: HP HPSA
   Driver Version: 5.5.0
   Driver Supports HP SSD Smart Path: False

 

 

now i put a ssd disk samsung dc on my server dik lights are on but in raid controller not detect ssd disk i have attached ssd disk info

 

now how can solve the problem?

 

best reards

 

Proliant ML110 G5 no video

$
0
0
 

Hello, 

 

HP Proliant ML110 G5 no video showing and CPU fan spinning is high all the time.

It was not accessible via network.

It was working on friday. Today it was in such condition.

Tried on different monitors.

Replaced power supply and RAM. Took off the system battery for some time. Not  helped.

proliant ml350p gen8 hpe ssa offline mode

$
0
0

Hi there,

I have changed the HP p420i controller to hba mode (I need to use ZFS on this server) but I cannot set the boot volume/drive as per the instructions in "HPE Smart Storage Administrator User Guide".

None of the offline modes works as described:

1. Pressing F5 via serial console after Smart Array controller menu does not launch hpssacli as described in the above guide (instead the system goes to HP intelligent provisioning)

2. Runnig HPE SSA from an HP Service Pack for ProLiant(SPP) ISO image works but when entering the command "hpssacli controller slot=0 physicaldrive xx:xx:xx modify bootvolume=primary" responds with "Error: this command is only valid in the offline environment"

Thanks,

Dimitris Beletsiotis

 