Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

DL360 G5 RAID

$
0
0

Hi guys,

I have a DL360 G5 with 6 disks. in a RAID1 configuration.

I have a used disk that is not currently in the server but contains data that I need to retrieve.
Please can someone advise the best way of getting this data from the disk? I would put it into the server to retrieve, however this will start off an automatic rebuild, which will lose the data. Is there a way around this?

Thanks in advance.


HP ProLiant Server DL 380 G6 Visio Stencil

$
0
0

Hi All,

I need HP ProLiant Server DL 380 G6 Visio Stencil. Kindly Help. I Have Checked Visiocafe but didn't find there.

 

 

 

DL 360 G6 - Microsoft Windows Server 2008 (64-bit)

$
0
0

Can I install "Microsoft Server 2008 R2 64 bit SP1" on a HP DL 360 G6 machine from the setup disk?

Are they compatible?

iLO4 unreachable

$
0
0

On a large number of my company's DL360p Gen8 servers the iLO appears to be completely unreachable.

We are running CentOS 6.6, the iLO firmware is at 2.30.

The servers are off warranty and the cost of swapping out the system board is too high.

The symptoms are:
Errors during post: Instead of getting the message to hit F8 to configure, I get an error message. See attached picture.

Intelligent provisioning won't load: I hit F10 during POST, it marks that I hit it, but it makes no visible effort to load it. hitting F11 and then choosing intelligent provisioning does nothing, also. 

Running hponcfg at the OS prompt gives errors. I ran it twice in the example shown the errors are slightly different.

[root@cnt]# hponcfg

HP Lights-Out Online Configuration utility

Version 4.4.0 Date 06/13/2014 (c) Hewlett-Packard Company, 2014

 

ERROR: CpqCiCreateFunc() 0 time failed.

Driver Error Code:(1,1h).

Driver Error Message: CPQCIDRV driver is not loaded.

ERROR: Error communicating with ILO

ERROR: Unable to communicate with the Management Processor.

[root@cnt ~]# hponcfg

HP Lights-Out Online Configuration utility

Version 4.4.0 Date 06/13/2014 (c) Hewlett-Packard Company, 2014

 

ERROR: CpqCiCreateFunc() 0 time failed.

Driver Error Code:(1,1h).

Driver Error Message: CPQCIDRV driver is not loaded.

 

ERROR: CpqCiCreateFunc() 1 time failed.

Driver Error Code:(1,1h).

Driver Error Message: CPQCIDRV driver is not loaded.

ERROR: A general system error occurred while detecting Management Processor.

ACTION REQUIRED: Check if iLO and iLO driver are up and running.

[root@cnt ~]#

 

When I run ipmitool nothing happens, I have hit cntl-c to get back to the prompt.

On some of the servers the iLO responds to pings, some don't.

The ones that respond to pings, seem to allow loading of the iLO logon page, but it doesn't allow me to put in any user information and that page loads extremely slowly.

I have tried the following:

Disconnecting all power for a full minute and powering back up.

Re-running the firmware install for version 2.30 from the OS prompt. This returned erorrs similar to hponcfg.

Toggling system maintenance switch 1 and 6 and booting in between.

cant add warranties..............

$
0
0

Why is HP's website a constant struggle?  ive been in IT for 10 years, and HP's website has never worked.  Timeout's, slow page loads, cant find serial numbers, cant link warranties, carepacks not showing up, why is this an issue for so long?

Anyways, i need someone from HP to contact me that can get my servers added, everytime i put in SN/PN it says it cant find it....

The best fiber type for Adapter hp 82q 8gb pci-e fc hba dual port. LC or FC ?

$
0
0

Hi,

I have one adapter  hp 82q 8gb pci-e fc hba dual port and now I want to buy an optical fiber cable for its interconnection. What's the best cable type for this achievement. LC type or FC type ?

Attachment: The Adapter AJ764A

 

 

HP Array P410, HDD changed, but still predict to fail soon

$
0
0

On HP Proliant DL G6, one disk in RAID 1 on P410 array broken. It was HP EG0300FBDBR. I changed it on compatible HP model - HP EG0300FAWHV. (both 300 Gb, 10K)

But HP Array Configuration Utility still show me - that new HP EG0300FAWHV - 300 GB 2-Port SAS Drive at Port 1I : Box 1 : Bay 0 is predicted to fail soon.

New disk in server blinking green - is like "The drive is rebuilding, erasing, or it is part of an array that is undergoing capacity expansion or stripe migration."

But two days gone and status didn't change.

In RIS Event Log, last info:

*> Event 123 2016-02-08 11:56:54 Hot Plug Physical Drive Change Removed.

Physical drive number: 0x09. Configured drive flag: 1. Spare drive flag: 0. Big drive: 0x00000009. Enclosure Box: 00. Bay: 00 Event 124 2016-02-08 12:16:57 Hot Plug Physical Drive Change Inserted. Physical drive number: 0x09. Configured drive flag: 1. Spare drive flag: 0. Big drive: 0x00000009. Enclosure Box: 00. Bay: 00 Event 125 2016-02-08 12:16:57 Logical Drive Status State change. State change, logical drive 0x0000. Previous logical drive state (0x03): Logical drive is degraded. New logical drive state (0x04): Logical drive is ready for recovery operation. Spare status (0x00): No spare configured Event 126 2016-02-08 12:16:57 Logical Drive Status State change. State change, logical drive 0x0000. Previous logical drive state (0x04): Logical drive is ready for recovery operation. New logical drive state (0x05): Logical drive is currently recovering. Spare status (0x00): No spare configured Event 127 2016-02-08 12:51:51 Logical Drive Status State change. State change, logical drive 0x0000. Previous logical drive state (0x05): Logical drive is currently recovering. New logical drive state (0x00): Logical drive OK. Spare status (0x00): No spare configured Event 128 2016-02-09 03:23:22 Logical Drive Surface Analysis Surface Analysis pass information. Block count: 00000000. Drive No: 00. Starting Address: 00000848:00000000.*

I attached ADU report.

Is it mean that new disk still recovering? But why its status as "predict to fail" and why so long for recovering? Why HP utility didn't mark it as rebuilding?

Report ADU: https://www.dropbox.com/s/70ucdsiafzdwvfr/ADUReport.zip?dl=0

report from HPSSACLI: dropbox.com/s/jml43anepzhqyq5/HPSSACLI.txt?dl=0

LSI Raid card not detected on HP ML10v2

$
0
0

The LSI raid controller 8888elp is not detected by the BIOS on booting it also makes long beeping sound on POST. I even tried to update the firmware on the raid card and updated my ML10v2 BIOS as well. The LSI raid controller works well on my other system with UEFI BIOS.

I am banging my head against the wall to figure this out..... Please Help.


p410i support SSD

ML110 G7, fans go on full, no VGA out or HD activity

$
0
0

After suffering a powower outage, my "trusty" ML110 G7 has a problem, it won't boot :-(

When I connect power to it, the fans come on at full blast, but nothing further happens, no VGA output, no disk activity, and the NIC does not show link.

No response to the power button, even if held in for 9 seconds, the only way to make the noise stop is to pull the power again.

I have tried removing the CMOS battery for 10 minutes and powering up, but no joy.

It is/was my home test box for hyper-v, so no carepaq on it and it is out of warranty.

Is it time to replace it ?

Cheers

Question on swaping HDs

$
0
0

I have an HP ProLiant DL380G6 server with a failed HD. I have an old HP ProLiant DL380G6 server sitting around with the same typ of HDs. 6G DP 10K SAS 300 GB Spare 507284-001. 

I want to know if I can take one from the server that is just sitting there and swap it in for the failed HD? It more than likely still has data on it so I wan to make sure that will not cause and issue during the rebuild process.

Thanks,

 

Install Hyper-V in a HP 32GB microSD Mainstream Flash Media Kit

$
0
0

Hello we bought a ml350g9 for virtualization through Hyper-V.
Our HP sales-specialist has strongly advised us to install hyper-v on "HP 32GB microSD Flash Mainstream Media Kit" rather than RAID1 SAS.
Do you think this choice is right? I have some doubts in installing the operating system on a single SD card.

Thanks in advance

Strange bad sequential write speed of the H240ar disk controller in RAID1 mode

$
0
0

Hi all!

I am currently doing setup of server DL360 Gen9 (K8N32A) with H240ar controller (2GB cache + battery) and 2 SAS HDD (15k).
I have updated BIOS and the latest Firmware (v3.56 for H240ar).


I had the strange results when done dumb testing with sequential writes using "dd" (OS FreeBSD 10.2).

1) When I did the test in HBA mode (software mirror) I got excellent results (I compared the results with two other similar servers):

# diskinfo -t da0
da0
        512             # sectorsize
        300000000000    # mediasize in bytes (279G)
        585937500       # mediasize in sectors
        0               # stripesize
        0               # stripeoffset
        71806           # Cylinders according to firmware.
        255             # Heads according to firmware.
        32              # Sectors according to firmware.
                0TV423MJ        # Disk ident.

Seek times:
        Full stroke:      250 iter in   1.963112 sec =    7.852 msec
        Half stroke:      250 iter in   1.407693 sec =    5.631 msec
        Quarter stroke:   500 iter in   1.495174 sec =    2.990 msec
        Short forward:    400 iter in   0.410938 sec =    1.027 msec
        Short backward:   400 iter in   1.137867 sec =    2.845 msec
        Seq outer:       2048 iter in   0.116620 sec =    0.057 msec
        Seq inner:       2048 iter in   0.269316 sec =    0.132 msec
Transfer rates:
        outside:       102400 kbytes in   0.408835 sec =   250468 kbytes/sec
        middle:        102400 kbytes in   0.457162 sec =   223991 kbytes/sec
        inside:        102400 kbytes in   0.562953 sec =   181898 kbytes/sec

-----------------------------
# dd if=/dev/zero of=/jails/tmp.dat bs=2048k count=2k
2048+0 records in
2048+0 records out
4294967296 bytes transferred in 1.551414 secs (2768421105 bytes/sec)

-----------------------------
# dd if=/dev/zero of=/jails/tmp.dat bs=2048k count=50k
51200+0 records in
51200+0 records out
107374182400 bytes transferred in 35.009251 secs (3067023135 bytes/sec)



2) But then I decided to use the Hardware RAID1 mode with r/w cache (default settings). And I got the odd bad result:

# diskinfo -t da0
da0
        512             # sectorsize
        299966445568    # mediasize in bytes (279G)
        585871964       # mediasize in sectors
        0               # stripesize
        0               # stripeoffset
        71798           # Cylinders according to firmware.
        255             # Heads according to firmware.
        32              # Sectors according to firmware.
        PDNLH0BRH9E8OX          # Disk ident.

Seek times:
        Full stroke:      250 iter in   0.400514 sec =    1.602 msec
        Half stroke:      250 iter in   0.755768 sec =    3.023 msec
        Quarter stroke:   500 iter in   2.386514 sec =    4.773 msec
        Short forward:    400 iter in   1.228658 sec =    3.072 msec
        Short backward:   400 iter in   0.980554 sec =    2.451 msec
        Seq outer:       2048 iter in   0.154139 sec =    0.075 msec
        Seq inner:       2048 iter in   0.188522 sec =    0.092 msec
Transfer rates:
        outside:       102400 kbytes in   0.187210 sec =   546979 kbytes/sec
        middle:        102400 kbytes in   0.299430 sec =   341983 kbytes/sec
        inside:        102400 kbytes in   0.371288 sec =   275797 kbytes/sec

-----------------------------

# dd if=/dev/zero of=/jails/tmp.dat bs=2048k count=2k
2048+0 records in
2048+0 records out
4294967296 bytes transferred in 16.863843 secs (254684967 bytes/sec)



3) I tried to disable write cache, but it didn't help:

# diskinfo -t da0
da0
        512             # sectorsize
        299966445568    # mediasize in bytes (279G)
        585871964       # mediasize in sectors
        0               # stripesize
        0               # stripeoffset
        71798           # Cylinders according to firmware.
        255             # Heads according to firmware.
        32              # Sectors according to firmware.
        PDNLH0BRH9E8OX          # Disk ident.

Seek times:
        Full stroke:      250 iter in   0.713020 sec =    2.852 msec
        Half stroke:      250 iter in   0.727876 sec =    2.912 msec
        Quarter stroke:   500 iter in   2.306020 sec =    4.612 msec
        Short forward:    400 iter in   0.761613 sec =    1.904 msec
        Short backward:   400 iter in   0.944677 sec =    2.362 msec
        Seq outer:       2048 iter in   0.125513 sec =    0.061 msec
        Seq inner:       2048 iter in   0.120609 sec =    0.059 msec
Transfer rates:
        outside:       102400 kbytes in   0.418003 sec =   244974 kbytes/sec
        middle:        102400 kbytes in   0.459038 sec =   223075 kbytes/sec
        inside:        102400 kbytes in   0.565851 sec =   180966 kbytes/sec

-----------------------------
# dd if=/dev/zero of=/jails/tmp.dat bs=2048k count=2k
2048+0 records in
2048+0 records out
4294967296 bytes transferred in 17.832703 secs (240847799 bytes/sec)

-----------------------------
# dd if=/dev/zero of=/jails/tmp.dat bs=2048k count=50k
51200+0 records in
51200+0 records out
107374182400 bytes transferred in 511.838806 secs (209781246 bytes/sec)


I see that according to the test results the "Transfer rates" parameter better when the cache active, but this is not consistent with the results of tests with "dd".
And I'm very surprised that the results when you disable write cache for RAID1 does not coincide with the results for HBA-mode.

Can anyone explain this strange result?
This result is a consequence of incorrect system settings or a feature of the disk controller?
For example, do I need to align the disks when using RAID mode of H240ar disk controller (this was done in HBA mode)?

HP DL120 G9 server with SSD

$
0
0

Hi,

I need a not very expensive server, but i need very fast Hard Drives.

My choise here is HP DL120G9, but the hard drive controller does not support SSD, i was considering to buy P420i .

The idea is to create RAID 10 with 4 SSD for the database and files and RAID 1 with 2 SAS or SSD for O.S.

My choise for SSD is the Samsung Serie 850 Pro 1TB.

 

But maybe i could chose SAS 1TB 7.2k or SAS 900GB 10K, the performance is not the same, but i have been using SCSI and SAS all my life and it always did the job.

What are your thoughts on SSD on a database Server?

the O.S is Windows 2012 Server. 

The program runs on SQL express.

The program the users will work, is intense, it will end the papper usage in the company. Everything is to be done in the program, reports, photos uploads, financial, administration services, etc etc. So has you can see it will have alot disk usage. 

The company is small, it's about 10 users, but it have alot of work, and it's growing. 

My view for this server is to work for about 10 to 15 years.

I know this will come down to the price, but just forget that for awhile, what is your expert opinion.

 

Can i put Proliant Gen8 or 9 into an 10636 G2 Rack ?

$
0
0

Hello,

I have long time searched, and i don't know if i can put an HP Proliant ML350 g8 or 9 into an 10636 G2 rack.

I saw new racks be 75mm more deeper. 

I think that's change not many. 

But my question is :  Can i put Proliant Gen8 or 9 into an 10636 G2 Rack ?

Best Regards

IT_VBO


Server 2012 Gen8 - User profile service failed the logon

$
0
0

Hello All,

I was recently asked to help resolve a logon issue with a Gen 8 server running 2012 Essentials. The default Administrator account was disabled by the previous Admin, and the owner's login credentials fail with the message: "The user profile service failed the logon. The profile cannot be loaded." A permissions issue on the Users folder perhaps?

Normally, I would boot from the installation media and either overwrite sethc.exe or Utilman.exe with cmd.exe to gain access, but when booting from the HP media I am not able to get to the windows/system32 directory. I am unfamiliar with iLO and doubt if this company paid for a license to activate it, but noticed in the documentation there was a User Management utility. Does that control Windows accounts or iLO accounts?

Be fore I do anything drastic, I thought I would ask here to see if there is a built in utility, or media utility that would help me regain access to the server. Right now, nobody can logon to the server console using any account, but domain users can logon to workstations as normal.

Thank you for any advice.

DL380 Gen9 P440ar different Raids

$
0
0

Hello,

sorry for my bad english.

Is it possible to run different Raid-Levels  with the P440ar Controller.

For example one pair of drives is RAID 6 and the next pair os RAID 5. Is it possilbe to manage the RAIDs with the P440ar using only the main server withput additional shelfs.

Thanks in advance

Best regards

T.Wassner

ML380 G5 E5450 - not SLAT enabled

$
0
0

Hi

 

I wonder if someone can advise...

I bought the following server:

ML350 G5 Tower (6LFF) Xeon Quad Core E5450 3.0Ghz, 32GB RAM, 2x 600GB 15K SAS

I purchased this in order to install AzureStack but unfortunately I have found that this server is not SLAT enabled.  My question is do I have any options which would allow me to upgrade the hardware (CPU) in order to install AzureStack?

 

Thanks

 

update dl380 g7

$
0
0

Hi everybody,

I'm new to HPE and therefore I'm in trouble with this specific issue. I've update my server DL380 G7 with bootable Smart update V2014.09. All update are done, but now , at boot the controller say that I need to update to HPDA disk firmware. Now I've check on my system and I've HPD5, and seem that pass directly from HPD5 to HPDA is not possible. On the system is installed vmware therefore I can't execute any windows executable. How can do this intermediate update?

Many thanks

Regards

Stefano

DL360Gen9 hangs on Linux boot occasionally

$
0
0

We have 6 pieces DL360Gen9 servers which ALL sometimes do not start correctly and hang during Linux boot. We have more than 20 pieces DL360pG8 where the problem DOES NOT happen.

After 3 weeks of extensive testing and trying to find out why the problem happens only very few times and not during every boot we were able to narrow down the problem to a very small but critical issue.

The server hangs when calling BIOS Int13h to write data to disk. Obviously this only happens sometimes and only while loading the operating system and before the disk controller driver is loaded which probably replaces BIOS Int13h calls.

It is quite easy to repeat this problem by booting MSDOS 6.22 or FreeDOS from hard disk or from a USB stick and by starting the following batch file:

:loop

copy c:\command.com c:\test.tst

goto loop

It takes from 10 seconds to 4 hours for the problem to appear (this is probably the reason why the Linux boot does not hang every time but only occasionally) . Under MSDOS either a red screen of death appears or the copy command hangs. Under FreeDOS the following error is displayed on the screen: Invalid Opcode at D057 0206 0A82 ... We installed the SmartArray Controller firmware 3.56 and the BIOS 1.52. Attached are the screenshots of the error under MSDOS and FreeDOS. 

HP support refuses to accept this as an issue because they claim that in AHS they cannot see any error and for them all the hardware (exchangable parts) is working correctly and they cannot do anything.

Does anybody know if there is a solution or how to correctly report this issue to HPE? There must be or there will be others who will be affected by this problem, although only occasionally.