can't boot hp service pack for proliant to Update New Firmware (HP Proliant BL460c Gen8)

$
0
0

Hello Guys,

 

We tried to upgrade the Firmware on HP Proliant Bl460c gen8 last night, but the SPP image could not boot on the blade 
The image would start booting and then hang as shown below:
 
 
he current versions of FW for this iOMS blade are as below - BIOS version I31 12/20/2013
 
and the new SPP image files --> 843216_001_spp_2015.10.0-SPP2015100.2015_0921.6.iso (2015/10/0)
 
Can someone help me to solve this issue ? 
 
Best Regards,
Zainal Muttaqien

HP Proliant DL180se G6 server not booting

$
0
0

Lights-Out

Recently I found one of the 8 fans in the server got defective and replaced it with a new one.  After everything is wired up correctly, I pressed the boot button, and expect it will boot as usual.

However, after I pressed the button, the fans spins up to maximum as usual, but the whole server shut down again after 1 second and the health light flashing red rapidly.

I have checked I didn't mix up inlet and outlet wire , and i didn't find any problem in the Light-Out

 

 Could anyone here help me figure out what happened?

ML350 G6 - 776 (Ready for Recovery) - Queued for rebuilding.

$
0
0

I have a ML350 G6 that had a drive in a mirror set go bad.. Replaced the drive with an HP spare and it said it was rebuilding.. I checked back later that day and it said 776 (Ready for Recovery) Logical Drive 2 (931.5 GB, RAID 1) is queued for rebuilding.

I researched and found others with same issue and suggestions to upgrade firmware.. So I upgraded the firmware to 1.86.. Had same results as above..

ACU was also complaining about the battery so I replaced that with a new one, also same results as above..

Below is the ACU diag report as I'm unsure what to do at this point.. I cannot get this to rebuild.. 

Any help is apprecaited. Thanks

ACU Report

 

DL380 Gen9 - Fans running at high speed & POST errors

$
0
0

We have 2 identical DL380 Gen9 servers running as a pair of 2012 RDS servers.

Each with...
128GB RAM
2 x Xeon E5-2650v3 @ 2.30GHz
RAID 1 - 2 x SAS 15K 450GB
iLO configured

They are rack mounted, one on top of the other in an air-conditioned server room.

These were installed and commissioned July 2016.

We are experiencing an odd problem when they are required to restart, however it doesn't happen all the time but too often to ignore.

If one is restarted, the POST will put the internal FANs into high speed mode. This triggers the neighbouring DL380 to run its own fans at high speed too!

Not only does this happen, the DL380 that is restarting will not complete its POST. It will report errors such as…

"329-Power Management Controller FW error" and "312_HPE Smart Storage Battery 1 Failure"  Contact HPE support.

This also happens Vice Versa.

Yesterday evening both servers were restarted at the same time, following the Quick System diags (no errors found) via the iLO remote management interface and they both failed to start properly. They both stopped at 52% POST, both iLO ports replied to pings but were not accessible to manage.

The only way to overcome this problem was to remove all AC power cables (Redundant PSU present) and restart the servers individually. They started, no errors reported during POST and no errors reported in the IM Log.

Both Servers have been updated using the HP SUM April 2016 DVD in August but the problem still happens.

On a couple of occasions before the latest HP SUM update, the fans on both servers would run at high speed during normal operation for unknown reasons. After an hour or so, they both quietened down again.

How can one DL380 influence the other? are they psychic or are they communicating via the iLO somehow and how do I resolve this??

Just to throw something else in the mix, one of them had a Red Screen of Death RSOD yesterday during normal operation - x64 Exception Type 0E - Page-Fault Exception.

I will  raise a support ticket with HPE but any advice would be greatly appreciated.

Thanks,

Graham

HP DL controller which supports the 8Tb SAS ST8000NM0075 drives

$
0
0

Im looking for which HP DL servers or controllers support the 8Tb SAS ST8000NM0075 drives.

ACU CLI

$
0
0

Добрый день! Не уверена, что по адресу, подскажите, если нет - где можно спросить. У меня вот такая проблема: 

server gen 7 , было необходимо увеличить объем диска F , добавили диски физически, и через acu cli дали команду на добавление этих дисков в logicaldrive 2. Добавление прошло, но один из дисков засветился аварией - неисправен. Следующая команда должна была быть на расширение по максимуму ld 2, но она не проходит - так как вроде как есть неисправность. Remove этого неисправного диска из ld не проходит по той же видимо причине. Получается замкнутый круг. Заменя диска не помогает - другие втавленные диски сервер просто не видит и ребилд не запускается, возвращаем именно этот несиправный - начинается ребилд, но с тем же результатом. Что посоветуете?

Errore 776 Smart Array E200i - Pronta per il ripristino

$
0
0

Buongiorno a tutti,

i LED di tutti i dischi risultano verdi ma da ACU riscontro l'avviso 776 (pronto per ripristino) unità logica 1 è in attesa della ricostruzione. Solitamente la ricostruzione è automatica, ma in questa situazione non sembra andare a termine.

Ho provato a generare anche il report (in allegato) e sembrerebbe che siano addirittura 2 i dischi con problemi.
La macchina monta W2003 R2 e attualmente il backup fallisce (si chiude forzatamente a 28MB) e nell'eventvwr compare un errore su disco. Adesso proverò ad installare un altro tool per effettuare il backup della macchina.

Vorrei avere un Vs. consiglio su come agire. Ho paura che sostituire anche uno dei due dischi (vi chiedo conferma che siano su 2 i problemi) mi porti ad un fermo macchina. Questo perchè la ricostruzione potrebbe fallire in quanto anche l'altro disco necessario contiene errori.

Grazie per la collaborazione.

REPORT ACU

Smart Array E200i in Embedded Slot : SAS Array A : Device Error Report

Device          Severity Error                                                          
--------------- -------- ---------------------------------------------------------------
Logical Drive 1 Warning  Logical drive state: The logical drive is queued for rebuilding

Smart Array E200i in Embedded Slot : SAS Array A : Logical Drive 1 : Logical Drive Status

   Unit Status                          4 (0x04)
   Drive Failure Map                    0x00000000
   Read Error Count                     All Zeroes (32 x [0x0000])
   Write Error Count                    All Zeroes (32 x [0x0000])
   Drive Error Data                     All Zeroes (256 x [0x00])
   DRQ Time Out Count                   All Zeroes (32 x [0x00])
   Blocks Left To Recover               0x00000000
   Drive Rebuilding                     0x00
   Remap Count                          All Zeroes (32 x [0x0000])
   Replacement Drive Map                0x00000000
   Active Spare Map                     0x00000000
   Spare Status                         0x00
   Spare To Replace Map                 All Zeroes (32 x [0x00])
   Replaced Marked OK Map               0x00000000
   Media Exchanged                      0x00
                                        Position Media Exchange Ready Status       
                                        -------- -------------------- -------------
                                        0        False                Informational

   Cache Failure                        0x00
                                        Position Failed From Cache Data Loss Status       
                                        -------- --------------------------- -------------
                                        0        False                       Informational

   Expand Failure                       Success (0x00)
   Unit Flags                           0x01
                                        Position Unit Flags                      Status  
                                        -------- ------------------------------- --------
                                        0        Rebuild Aborted From Read Error Critical

   Big Drive Failure Map                All Zeroes (16 x [0x00])
   Big Remap Count                      All Zeroes (128 x [0x0000])
   Big Replacement Drive Map            0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
                                        Position Device                Status       
                                        -------- --------------------- -------------
                                        3        Physical Drive 1I:1:1 Informational


Smart Array E200i in Embedded Slot : SAS Array A : Logical Drive 1 : VPD Page 80 - Serial Number

   Product Serial Number                QT7BMV0414    

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:3 : Physical Drive Status

   SCSI Bus                             0 (0x00)
   SCSIID                               1 (0x01)
   Block Size                           512 Bytes Per Block (0x0200)
   Total Blocks                         146 GB (0x11177330)
   Reserved Blocks                      0x00010000
   Drive Model                          HP      DG0146FARVU    
   Drive Serial Number                          PCYZAY7E
   Drive Firmware Revision              HPDA
   SCSI Inquiry Bits                    0x02
   Compaq Drive Stamped                 Stamped For Monitoring (0x01)
   Last Failure Reason                  No Failure (0x00)
   Device Flags                         0x01
                                        Position Device Flag                   Status       
                                        -------- ----------------------------- -------------
                                        0        Drive Present And Operational Informational

   More Device Flags                    0x25
                                        Position Device Flag                           Status       
                                        -------- ------------------------------------- -------------
                                        0        SMART Predictive Failure Supported    Informational
                                        2        SMART Predictive Failure Is Enabled   Informational
                                        4        Device Attached To Internal Connector Informational
                                        5        Configured Data Drive                 Informational

   SCSI Lun                             0x00
   Yet More Device Flags                0xa0
                                        Position Device Flag                             Status       
                                        -------- --------------------------------------- -------------
                                        5        Does Not Support Redundant Controllers  Warning      
                                        7        Drive Write Cache Setting Is Changeable Informational

  
Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:3 : Monitor and Performance Statistics (Since Factory)

 

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:3 : Monitor and Performance Statistics (Since Reset)

   Serial Number                                PCYZAY7E
   Firmware Revision                    HPDA
   Product Revision                     HP      DG0146FARVU    
   Reference Time                       0x0002222d
   Sectors Read                         0x00000001774528f8
   Read Errors Hard                     0x00000000
   Read Errors Retry Recovered          0x00000000
   Read Errors ECC Corrected            0x0000000000000000
   Sectors Written                      0x000000001e932581
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000000
   Seek Count                           0x0000000000000000
   Seek Errors                          0x0000000000000000
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0x0000
   Performance Test 3                   0x0000
   Performance Test 4                   0x0000
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0x00000000
   DRQ Time Outs                        0x0000
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0000
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0x0000
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0x00000000
   IRQ Deglitch Count                   0 (0x00000000)
   Bus Faults                           0x00000000
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0000
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:2 : Monitor and Performance Statistics (Since Factory)

   Serial Number                        3SD3JJFT0000905089K1
   Firmware Revision                    HPDE
   Product Revision                     HP      EG0146FAWHU    
   Reference Time                       0x0029da40
   Sectors Read                         0x0000005948897023
   Read Errors Hard                     0x000010c0
   Read Errors Retry Recovered          0x00000003
   Read Errors ECC Corrected            0x0000000000000000
   Sectors Written                      0x0000000f393a0d6e
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000005
   Seek Count                           0x0000000000000000
   Seek Errors                          0x0000000000000000
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0x0000
   Performance Test 3                   0x0000
   Performance Test 4                   0x0000
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0x00000001
   DRQ Time Outs                        0x0000
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0004
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0x0000
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0x00000000
   IRQ Deglitch Count                   0 (0x00000000)
   Bus Faults                           0x00000000
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0001
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:2 : Monitor and Performance Statistics (Since Reset)

   Serial Number                        3SD3JJFT0000905089K1
   Firmware Revision                    HPDE
   Product Revision                     HP      EG0146FAWHU    
   Reference Time                       0x0002222d
   Sectors Read                         0x000000016b7fa925
   Read Errors Hard                     0x00000e5c
   Read Errors Retry Recovered          0x00000000
   Read Errors ECC Corrected            0x0000000000000000
   Sectors Written                      0x000000001d169626
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000000
   Seek Count                           0x0000000000000000
   Seek Errors                          0x0000000000000000
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0x0000
   Performance Test 3                   0x0000
   Performance Test 4                   0x0000
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0x00000000
   DRQ Time Outs                        0x0000
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0004
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0x0000
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0x00000000
   IRQ Deglitch Count                   0 (0x00000000)
   Bus Faults                           0x00000000
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0000
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:2 : Serial SCSI Physical Drive Error Log

   Entry Size                           20 (0x14)
   Entry Count                          64 (0x0040)
   Next Entry Offset                    0x3b
   Errors Logged                        443 (0x000001bb)
   Reference Time                       0x00000000

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:2 : Mode Sense 10

   Header                               0x00 0xce 0x00 0x10 0x00 0x00 0x00 0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x02 0x00

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:2 : VPD Page 80 - Serial Number

   Product Serial Number                3SD3JJFT0000905089K1

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:1 : Physical Drive Status

   SCSI Bus                             0 (0x00)
   SCSIID                               3 (0x03)
   Block Size                           512 Bytes Per Block (0x0200)
   Total Blocks                         146 GB (0x11177330)
   Reserved Blocks                      0x00010000
   Drive Model                          HP      DG146ABAB4     
   Drive Serial Number                  3NM4EKG600009828Y0FX
   Drive Firmware Revision              HPDA
   SCSI Inquiry Bits                    0x02
   Compaq Drive Stamped                 Stamped For Monitoring (0x01)
   Last Failure Reason                  Hardware Error (0x0d)
   Device Flags                         0x01
                                        Position Device Flag                   Status       
                                        -------- ----------------------------- -------------
                                        0        Drive Present And Operational Informational

   More Device Flags                    0x25
                                        Position Device Flag                           Status       
                                        -------- ------------------------------------- -------------
                                        0        SMART Predictive Failure Supported    Informational
                                        2        SMART Predictive Failure Is Enabled   Informational
                                        4        Device Attached To Internal Connector Informational
                                        5        Configured Data Drive                 Informational

   SCSI Lun                             0x00
   Yet More Device Flags                0xa0
                                        Position Device Flag                             Status       
                                        -------- --------------------------------------- -------------
                                        5        Does Not Support Redundant Controllers  Warning      
                                        7        Drive Write Cache Setting Is Changeable Informational

 
Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:1 : Monitor and Performance Statistics (Since Factory)

   Serial Number                        3NM4EKG600009828Y0FX
   Firmware Revision                    HPDA
   Product Revision                     HP      DG146ABAB4     
   Reference Time                       0x0042f067
   Sectors Read                         0x0000009716f9a0c8
   Read Errors Hard                     0x00000000
   Read Errors Retry Recovered          0x0000001d
   Read Errors ECC Corrected            0x0000000000000004
   Sectors Written                      0x000000107d9e18aa
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000004
   Seek Count                           0x0000000000000000
   Seek Errors                          0x0000000000000000
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0x0000
   Performance Test 3                   0x0000
   Performance Test 4                   0x0000
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0x00000000
   DRQ Time Outs                        0x0000
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0000
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0x0000
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0x00000000
   IRQ Deglitch Count                   0 (0x00000000)
   Bus Faults                           0x00000008
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0006
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

Smart Array E200i in Embedded Slot : Internal Drive Cage at Port 1I : Box 1 : Drive Cage on Port 1I : Physical Drive 1I:1:1 : Monitor and Performance Statistics (Since Reset)

   Serial Number                        3NM4EKG600009828Y0FX
   Firmware Revision                    HPDA
   Product Revision                     HP      DG146ABAB4     
   Reference Time                       0x0002222d
   Sectors Read                         0x00000000000613f5
   Read Errors Hard                     0x00000000
   Read Errors Retry Recovered          0x00000000
   Read Errors ECC Corrected            0x0000000000000000
   Sectors Written                      0x000000001b2f3b2b
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000002
   Seek Count                           0x0000000000000000
   Seek Errors                          0x0000000000000000
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0x0000
   Performance Test 3                   0x0000
   Performance Test 4                   0x0000
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0x00000000
   DRQ Time Outs                        0x0000
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0000
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0x0000
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0x00000000
   IRQ Deglitch Count                   0 (0x00000000)
   Bus Faults                           0x00000000
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0001
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

HP ProLiant DL360 server

$
0
0

I have HP ProLiant DL360 server with RAID 5 (HP Smart Array E200 Controller).
OS - Ubuntu 16.04 LTS.

I want to set up alerts from RAID to e-mail. Is it possible to do it using hardware capabilities only?
If not, would you be so kind to tell me how to do it using software, smartmontools for example.

 
 

Solaris 10 for HP DL380 Gen9 E5-2620v3

$
0
0

Hello Experts,

 

I am middle of a project and my application supports only Solaris 10 update 11 where as my server is a new generation HP DL380 Gen9 E5-2620v3. Kindly support us by suggesting any tweak or patch to accomodate the Solaris 10 for this particular project.

Regards

Chitrasen

Solaris 10 support the HP DEL380 GEN 9 Server

$
0
0

Dear Team,

Greeting!!!!

I am trying to install the Solaris 10 in HP Del380 Gen9 Server and my server serial no is :-  CZ3628EMPX.

I am stucking after the boot the server from the Solaris 10 DVD and its not proceeding further.

kindly let me know any alternate how i can install the Solaris 10 in HP Del 380 Gen9.

 

 

HP DL580 G7 error code

$
0
0

There are 2 DL580G7 normal operation after the restart, now the 2 machines are not power, connect the power line, press the switch button will hear sound alarm, "Ding Ding" machine diagnostic panel all memory alarm display, no display output machine. Observe the display code on the machine IO board as "40". May I ask what's going on here? How to solve? Thank!

HP proliant DL160G6 - p410 raid controller problem

$
0
0

Hello.

I've a raid controller which is HP Smart Array P410. 

also I've four SATA3 HDDs(1TB * 2ea, 2TB * 2ea) which are all HGST.

I want to organize raid-10.  Fig 1 is my plan.

Fig 1. My plan

I've selected four disks for raid-10 (Fig 2).

 

Fig 2. Select four disks and raid-10 option.

However, only 1863.0GB is available(Fig 3).  I anticipate about 3TB disk size.  How can I solve the this problem?

 

Fig 3. Raid-10 disk capacity problem.

I'm alreay updated p410 raid controller firmware. (v3.0 -> v6.64) however, It still shows 1.8 TB disk size that consist of raid-10.

Fig 4. hpacucli ctrl all show detail

hpacucli ctrl all show config

Fig 5. hpacucli ctrl all show config

hpacucli ctrl all show status

Fig 6. hpacucli ctrl all show status

Fig 7 is Raid-5 setting using four disks. Is 3.00TB disk size(raid-5) correct? 

Fig 7. Riad-5 test

HP ProLiant DL360 server and RAID 6

$
0
0

I have HP ProLiant DL360 server with RAID 5 (HP Smart Array E200 Controller).
OS - Ubuntu 16.04 LTS.

The output  hpacucli ctrl slot 0 = show  gives the result:

Smart Array E200i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: PR78MV1116
Cache Serial Number: P9A3A0B9SU35MY
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: A
Firmware Version: 1.86
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 50% Read / 50% Write
Drive Write Cache: Enabled
Total Cache Size: 128 MB
Total Cache Memory Available: 96 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: False

But I do not understand the line "RAID 6 (ADG) Status: Disabled". As far as I know, HP Smart Array E200 Controller does not support RAID 6. Why displays information about it?

Unable to modify ILO Administrator user

$
0
0

Hello, I will appreciate every advice on this issue.

I have ML350 Gen9 server, I'm using hponcfg.exe utility for ILO port automatic configuration.

I successfully logon ILO management with active Administrator user and password. When I'm trying to modify Administrator user with hponcfg.exe I get error message : User Login name was not found. 

<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="Administrator" PASSWORD="validpassword">
<USER_INFO MODE="write">
<MOD_USER USER_LOGIN="ILO_admin">
<PASSWORD value="newpassword"/>
</MOD_USER>
</USER_INFO>

/RIBCL>

I successfully logon using user: Administrator  password: validpassword

Why does the script fail with error message "User Login name was not found" ?

Thank you in advance.

DL580 Gen8

$
0
0

My DL580 Gen8 is only detecting 3 processors, it says the 4 is not installed?  Would this be a driver issue? I clearly purchased a server with 4 processors?


ML110 Gen9 esxi 6 high fan speed

$
0
0

Hi,

i have a brand new ML110 Gen9 without any HDD and installed VMware-ESXi-6.0.0-Update2-3620759-HPE-600.9.5.0.48-Apr2016 onto an internal SD-Card (tried it with an usb-stick too). The Problem is, that the fan wont go lower than 38-40%. If i go into the SSA (storage config) menu to configure HDDs the fan speed drops to 13%, but in esxi not. Is this a known problem, as i have the feeling that its not a hardware but software problem.

FirmwareInfo: I updated the server with the 2016.04 ServicePack and updated ilo to 2.44

 

thx in advance

Mike

B320i and VMWare ESXi

$
0
0

I have two HP ProLiant DL360e (G8) with B320i controller (512MB with battery). If i install Windows 2008R2 or Hyper-V everything working fine (normal hdd speed and iops). But when i install ESXi server (5.0, 5.1, 5.5, 6.0) the speed is very slow (only 70 iops) and any manipulation with ACU (enable Cash or disable and other) don't do anything.
Are there any considerations?

HPE ProLiant and Care Packs: what to choose to be entitled for download access AFTER 1st year?

$
0
0

Hello all,

I have a question about the entitlement a Customer/Reseller should have to ensure to be able to download BIOS updates AFTER the 1st year of support's end.

If the Active Warranty of an HPE ProLiant DL180 Gen9 will end after its 1st Year of purchase, then which base support agreement covering that HP Proliant server model must be chosen to continue to access BIOS Downloads AFTER that date?

Is there a basic Care Pack to choose? if so, which code/name it has (Foundation Care/Proactive Care, what else?)?

I mean: I will not need the 24x7, Call or NBD...just the possibility to continue to Download BIOS/Firwmwares and released SPP (Service Pack for ProLiants) AFTER 1st Year of purchase.

Is there a document that explains all the possible options in a clear and simple way?

Thanks!

Warranty of midline hard disks inside a Proliant System with 3yr carepack

$
0
0

Good day to all,

If I have a Proliant DL180Gen9 that I have applied at purchase time the carepack:

U7AT3E / HPE 3 year Foundation Care 24x7 DL180 Gen9 Service

and at the same time i purchased in the same PO the following disks:

782669-B21 / HP 6TB 6G SAS 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive

And hipotetically one (or several) disks fail at month 24. 

1- Will my Proliant 3/3/3 warranty covers the disks?

2- Or is the Foundation Care that covers the disks?

3- Or (see below) Im out of warranty because the disks claim 1yr warranty?

 

From the HP SAS Hard drives document:

SAS Enterprise hard drives have a 3 year limited warranty regardless of the warranty period for the system in which they are installed.
SAS Midline hard drives have a 1 year limited warranty regardless of the warranty period for the system in which they are installed.

 

4. Or because of this, then I do have protection and the disks can be replaced?

Service and Support

NOTE: HPE SATA and SAS Hard drives are covered under the HPE Care Pack/ Service Contract applied to the HPE ProLiant Server. No separate HPE Care Packs need to be purchased.

This question is because I want to build a scale-out configuration with large (bigger than 2TB) drives and ENT drives go up to 1.8TB but Midline have 2TB, 4TB and 6TB drives.

Thanks for your advice. My local HP Supplier bailed out on this question and a HP LATAM representative I spoke to was only able to roboticly-read the warranty lines on PDF files and suggested I go with ENT drives for the 3yr warranty avoiding my "I dont need 1.8TB drives" comments.

Thanks for your comments.

xen server 6.0.2 SMH

$
0
0

I have 2 DL380 G7 servers running Citrix XenServer 6.0.2 what is the highest version of SMH that i can run with this version it looks like 7.3.3.  but that is what i get on the website but the release notes for 7.3.3 say XenServer 6.2.0