esxi 6 problem on G7

$
0
0

We have some DL380 G7's I'm trying to install ESXi 6.0 U3 on. The servers are working fine and fully up to date with all firmware. The RAID controller is a standard P410i.

All the drive bays are full as follows

Bay 1/2 : 2 x HP 72GB SAS (RAID1)

Bay 3/4/5/6/7/8 : 6 x HP 300GB SAS (RAID5)

I'm using the HP custom image of ESXi 6 U3 from Feb 2017, but have also tried the standard VMware one.

When installing ESXi, the process will hang at the message 'vmkibft loaded successfully' and not get any further. After much testing, I found if I remove the RAID5 array from the system, so I just have the RAID1 disks, everything works perfectly and the install completes ok. Re-enable the RAID5 array, and the boot process hangs again at the same place. Research has shown this is a common problem, and affects ESXi 5.5 as well on the same hardware. There was no single fix though from what I could find.

Is there *any* solution to this? It's massively frustrating when I just need to install ESXi which is normally a very quick process.

Thanks


Second Processor in ML330 G6 not working

$
0
0

Hi there!

I recently mounted the 2nd CPU board to my ML330 G6 in my homelab.

However, it seems the board is defective because it detects the CPU but always tells me CPU error and the second CPU is not enabled (also red LED at the front panel starts flashing during late POST).

I already pulled my hair trying to get it to work and tried everything (BIOS update, BIOS reset, Firmware updates, re-seating, various memory configurations, swap CPUs, ...). The CPUs are both pulled from another server so they worked together in one system already, are the same type and stepping and I also swapped them and always the CPU in the 2nd socket is not working (212 POST Error, CPU 2 failed).

If I populate the memory the wrong way, the LEDs on the mezzanine board light up so it definitely has some good connection to the motherboard - also the 2nd CPU is detected but disabled due to some error.

If I don't connect the power cable of the mezzanine board, the server doesn't even turn on (turns off again within 1 second) so the mezzanine board isn't entirely dead...

The CPUs are both Xeon X5650.

Any idea if I might be missing somethiing or do you think that the CPU board is defective?

Thanks!

 

Do you know/remember if this mezzanine board has been pulled from a working server? Do you have any idea what I might try?

Cannot install windows svr 2012 R2 on HP DL380 G9

$
0
0

I'm trying to install windows server 2012 R2 on a physical svr HP DL380 G9 using Hp inteligent provisioning ver 2.50.164 but when windows installing I got this error "Windows cannot find the Microsoft Software License Terms. Make sure the installation sources are valid and restart the installation"

If I install svr 2012 R2 directly from the CD not using Inteligent provisioning it's success  or if I install windows 2k8 R2 using inteligent provisioning, it's also success.

How can I fix this error?

Disable Disk Temperature Sensor on DL380 G7

$
0
0

i have been reading threads about the fans going crazy because the temperature sensor #29 is high, but the disk i installed are non-hp so they may be a little more temperature intensive.

 

is there any way to raise the limits or disable the sensor?

 

ProLiant DL320 G6 ilo2 ver 2.29 looses connection

$
0
0

Sitting and trying to install a ProLiant DL320 G6, but the iLO looses connection all the time. (while I am still able to ping other nodes on the same subnet as the Proliant.

My idea is that the server loops on a reboot causing the iLO to loose link (it is a shared NIC). Does this make sence? Can I avoid it in any way? The server is in another country than me, so I can't get a physical hold on it.

Regards, Lars.

ProLiant DL320 G6 Windows 2016 support

$
0
0

Is it possible to install Windows 2016 on a ProLiant DL320 G6? On the download support for the server there are no drivers for Windows 2016, and when I try just to boot on the Windows 2016 installation USB, it tells me that there are no drives to install it on (but there are two sata driver in a RAID on an HP Smart Array B110i SATA controller.

When I download a Windows 2012 driver for the controller, I am then able to find and partition the disk, but when I select it for installation, it tells me that I cannot use the disk, maybe because it is not included in the boot order (or something similar) I am not able to enter the the BIOS (as indicated in my prior post) via iLO.

Regards, Lars.

Microserver Gen 8

$
0
0

Hello!

 

I have 2 Microservers Gen 8. Both are the same Product ID and updatet with SPP 2016.10. In Ilo System Information - Device Inventory the integrated Networkadapter 332i is shown as HP Ethernet 1Gb 2-port 332i Adapter #2. Both are running Server 2012R2. All other Microservers Gen 8 we have have the same patchlevel but they are showing the 332i correct HP Ethernet 1Gb 2-port 332i Adapter.

What could be wrong?

Lutz

Virtualization with SSD

$
0
0

what should i look for SSD if i want to make a virtual machine... i might have 6 virtual machine 3 of them is Database server, 1 File server, 1 Backup server and 1 Test server.

should i check for Sequencial Read/Write or 4k Read and Write? is consumer MLC SSD is already enough?


Restore ML10 on AC Power loss and graceful shutdown

$
0
0

I have three new HPE ML10 gen9 servers and one older HP ML10 V2 connected to a APC Smart-UPS 750 with a AP 9631 Network Management Card and PowerChute Network Shutdown. Working on battery works fine and will in the end perform a graceful shutdown. The problem comes when power returns as the system seems configured to "Last state" when it ought to be "Power on".

I have entered the Intel® Aptio Setup Utility and the Intel® MEBX during boot and searched for a Restore AC Power loss configuration menu on the ML10 gen9, but can't find any. Have not yet tried on ML10 V2. I really hope there is such a setting on the gen9 server and would be very suprised if not!

Any help in this matter will be appreciated!

HP Proliant DL 180 G6 Continuously Automatic Restarting With Event ID 6008 and Event ID 41

$
0
0

Dear Sir;

I have server HP Proliant DL-180 G6 having windows server 2008 r2 Enterprise installed with Exchange 2010. My server is continually crashed and rebooting (Sometimes Halt and we have to manually restart and sometimes automatically restarts) . In Event viewer of Operating System Events ID: 6008 and Event ID: 41.

Event ID 41:

=============

Critical    29/04/2017 2:40:34 AM    Kernel-Power    41    (63)

Critical    28/04/2017 4:07:14 PM    Kernel-Power    41    (63)

Critical    28/04/2017 10:45:11 AM    Kernel-Power    41    (63)
Critical    27/04/2017 4:06:57 PM    Kernel-Power    41    (63)
Critical    27/04/2017 10:06:38 AM    Kernel-Power    41    (63)
Critical    27/04/2017 5:02:19 AM    Kernel-Power    41    (63)
Critical    26/04/2017 9:49:46 AM    Kernel-Power    41    (63)
Critical    26/04/2017 6:42:30 AM    Kernel-Power    41    (63)
Critical    25/04/2017 10:45:47 PM    Kernel-Power    41    (63)
Critical    25/04/2017 11:10:46 AM    Kernel-Power    41    (63)
Critical    23/04/2017 6:48:09 AM    Kernel-Power    41    (63)
Critical    20/04/2017 1:34:40 PM    Kernel-Power    41    (63)

 

Event ID 6008:

===========

Error    29/04/2017 2:41:25 AM    EventLog    6008    None

Error    28/04/2017 10:45:55 AM    EventLog    6008    None

Error    27/04/2017 4:07:37 PM    EventLog    6008    None

 

I also checked ILO Logs Or BMC http server logs i found the following system event Log:

 

Generic

  04/26/2017 06:42:36 Gen ID 0x41 C: boot completed Assertion OEM 04/26/2017 06:42:36 000137 00 3e 41 00 59 00 -- Generic 04/26/2017 09:49:50 Gen ID 0x41 C: boot completed Assertion OEM 04/26/2017 09:49:50 000137 00 21 6d 00 59 00 -- Generic 04/27/2017 04:40:09 Gen ID 0x41 Run-time Stop Assertion OEM 04/27/2017 04:40:09 000137 01 d1 00 00 00 01 -- OEM 04/27/2017 04:40:09 000137 02 00 00 7d bf 01 -- OEM 04/27/2017 04:40:09 000137 02 00 00 00 00 01 -- OEM 04/27/2017 04:40:09 000137 03 02 00 00 00 01 -- OEM 04/27/2017 04:40:09 000137 03 00 00 00 00 01 -- OEM 04/27/2017 04:40:09 000137 04 01 00 00 00 01 -- OEM 04/27/2017 04:40:09 000137 04 00 00 00 00 01 -- OEM 04/27/2017 04:40:09 000137 05 3d 7e 16 06 01 -- OEM 04/27/2017 04:40:09 000137 05 80 f8 ff ff 01 -- Generic 04/27/2017 05:02:24 Gen ID 0x41 C: boot completed Assertion OEM 04/27/2017 05:02:24 000137 00 43 7b 01 59 00 -- Generic 04/27/2017 09:44:46 Gen ID 0x41 Run-time Stop Assertion OEM 04/27/2017 09:44:46 000137 01 d1 00 00 00 01 -- OEM 04/27/2017 09:44:46 000137 02 00 00 7d bf 01 -- OEM 04/27/2017 09:44:46 000137 02 00 00 00 00 01 -- OEM 04/27/2017 09:44:46 000137 03 02 00 00 00 01 -- OEM 04/27/2017 09:44:46 000137 03 00 00 00 00 01 -- OEM 04/27/2017 09:44:46 000137 04 01 00 00 00 01 -- OEM 04/27/2017 09:44:46 000137 04 00 00 00 00 01 -- OEM 04/27/2017 09:44:46 000137 05 3d ce 16 06 01 -- OEM 04/27/2017 09:44:46 000137 05 80 f8 ff ff 01 -- Generic 04/27/2017 10:06:45 Gen ID 0x41 C: boot completed Assertion OEM 04/27/2017 10:06:45 000137 00 92 c2 01 59 00 -- Generic 04/27/2017 10:21:04 PS2 Status Power Supply Failure detected Assertion Generic 04/27/2017 10:21:04 PSRed Status Redundancy Lost Assertion Generic 04/27/2017 10:21:16 PSRed Status Full Redundancy Assertion Generic 04/27/2017 15:08:21 Gen ID 0x41 Run-time Stop Assertion OEM 04/27/2017 15:08:21 000137 01 d1 00 00 00 01 -- OEM 04/27/2017 15:08:21 000137 02 00 00 7d bf 01 -- OEM 04/27/2017 15:08:21 000137 02 00 00 00 00 01 -- OEM 04/27/2017 15:08:21 000137 03 02 00 00 00 01 -- OEM 04/27/2017 15:08:21 000137 03 00 00 00 00 01 -- OEM 04/27/2017 15:08:21 000137 04 01 00 00 00 01 -- OEM 04/27/2017 15:08:21 000137 04 00 00 00 00 01 -- OEM 04/27/2017 15:08:21 000137 05 3d ce 0e 06 01 -- OEM 04/27/2017 15:08:21 000137 05 80 f8 ff ff 01 -- Generic 04/27/2017 15:24:33 PS1 Status Power Supply Failure detected Assertion Generic 04/27/2017 15:24:33 PSRed Status Redundancy Lost Assertion Generic 04/27/2017 15:24:48 PS1 Status Power Supply Failure detected Assertion Generic 04/27/2017 15:25:47 PSRed Status Full Redundancy Assertion Generic 04/27/2017 15:26:07 PS1 Status Power Supply Failure detected Assertion Generic 04/27/2017 15:26:07 PSRed Status Redundancy Lost Assertion Generic 04/27/2017 15:26:18 PSRed Status Full Redundancy Assertion Generic 04/27/2017 16:07:03 Gen ID 0x41 C: boot completed Assertion OEM 04/27/2017 16:07:03 000137 00 07 17 02 59 00 -- Generic 04/27/2017 16:14:39 Gen ID 0x41 Unavailable Assertion OEM 04/27/2017 16:14:39 000137 00 ff 00 05 00 00 -- Generic 04/27/2017 17:13:52 Gen ID 0x41 C: boot completed Assertion OEM 04/27/2017 17:13:52 000137 00 b9 26 02 59 00 -- Generic 04/27/2017 18:54:14 Gen ID 0x41 Run-time Stop Assertion OEM 04/27/2017 18:54:14 000137 01 d1 00 00 00 01 -- OEM 04/27/2017 18:54:14 000137 02 00 00 7d bf 01 -- OEM 04/27/2017 18:54:14 000137 02 00 00 00 00 01 -- OEM 04/27/2017 18:54:14 000137 03 02 00 00 00 01 -- OEM 04/27/2017 18:54:14 000137 03 00 00 00 00 01 -- OEM 04/27/2017 18:54:14 000137 04 01 00 00 00 01 -- OEM 04/27/2017 18:54:14 000137 04 00 00 00 00 01 -- OEM 04/27/2017 18:54:14 000137 05 3d 5e 0c 06 01 -- OEM 04/27/2017 18:54:14 000137 05 80 f8 ff ff 01 -- Generic 04/28/2017 10:45:16 Gen ID 0x41 C: boot completed Assertion OEM 04/28/2017 10:45:16 000137 00 82 1c 03 59 00 -- Generic 04/28/2017 15:57:40 Gen ID 0x41 Unavailable Assertion OEM 04/28/2017 15:57:40 000137 00 ff 00 05 00 00 -- Generic 04/28/2017 15:58:42 PS2 Status Power Supply Failure detected Assertion Generic 04/28/2017 15:58:42 PSRed Status Redundancy Lost Assertion Generic 04/28/2017 16:07:20 Gen ID 0x41 C: boot completed Assertion OEM 04/28/2017 16:07:20 000137 00 96 68 03 59 00 -- Generic 04/29/2017 02:10:34 Gen ID 0x41 Run-time Stop Assertion OEM 04/29/2017 02:10:34 000137 01 50 00 00 00 01 -- OEM 04/29/2017 02:10:34 000137 02 00 80 9b 44 01 -- OEM 04/29/2017 02:10:34 000137 02 80 fa ff ff 01 -- OEM 04/29/2017 02:10:34 000137 03 01 00 00 00 01 -- OEM 04/29/2017 02:10:34 000137 03 00 00 00 00 01 -- OEM 04/29/2017 02:10:34 000137 04 45 0c 1c 06 01 -- OEM 04/29/2017 02:10:34 000137 04 80 f8 ff ff 01 -- OEM 04/29/2017 02:10:34 000137 05 00 00 00 00 01 -- OEM 04/29/2017 02:10:34 000137 05 00 00 00 00 01 -- Generic 04/29/2017 02:40:38 Gen ID 0x41 C: boot completed Assertion OEM 04/29/2017 02:40:38 000137 00 02 fd 03 59 00 --

 

 

Event due to this problem i can not take the backup because server restart becomes Halt or Restart before completing the windows backup utility. I am afraid that system can crashed anytime. Please help me in this regard.

HP Proliant Microserver boot, but no display or network

$
0
0

Hi all,

I've had an HP Proliant Gen8 Microserver running a headless Ubuntu Server for the last couple of years without issue.
Recently however the server stopped responding and stopped showing up on the connected devices list of our router.
As I was unable to remote into the machine, I tried the steps below:

  • Restarting both the server and the router to no effect
  • Connecting directly to the server's iLO and LAN ports directly with a laptop over link-local, but the server does not appear to be assigning itself an address to connect to when sending a link-local broadcast ping from the laptop
  • Connecting the server's iLO port to the router instead, this didn't show up in the connected devices list on the router either
  • Removed all HDDs, attached a monitor and keyboard and attempted to boot to BIOS. Even with frantic mashing of all F* keys the server beeped twice to indicate a "successful boot" but no display is output even while booting

At this point I'm at a loss as to how to proceed. I want to try resetting the BIOS via the CMOS jumper, but I can't find a correct schematic or relevant notation on the system board and obviously don't want to go poking around blindly.

I also can't find the official product ID for contacting HP support? The only two IDs I have are G1610T from the supplier and 712317-421 from the rear of the machine.

Any advice would be greatly appreciated. Many thanks,

Martin

Verifying ASR status is disbaled

$
0
0

The purpose of ASR is to restart the HP ProLiant server once it is determined that the system is not responding.  I want to write a bash script to verify if ASR status is disabled. 

I think we can do it using hpasmcli

However, I have found that hpasmcli is not available on my RHEL linux VM. 

Please suggest how to write a bash script to verify if ASR status is disabled. 

ipmitool lan print on SLES 11.1 gives Invalid channel: 255 on ProLiant DL 380 G6

$
0
0

I am wits end trying to determine the lan channel to get ipmitool lan print command to give output.  Here is what I get:

# ipmitool lan print
Invalid channel: 255

ipmitool channel info 2
Channel 0x2 info:
Channel Medium Type : reserved
Channel Protocol Type : reserved
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 0

How do I set up the lan channel:  Other similar servers work fine and ipmitool power status command also works

HP prolient ML310 Gen8.0 v2 server initilization only 10%

$
0
0

We have a HP prolient ML310 Gen8.0 v2 server which was working fine for the past three years. I shut down this server and powered it up and it is only completing 10% initialization and stopping.  Could you please let me know why it is happening and not continuing with the reboot?

HP Server DL G9 Series and vSphere ESXi 6.5

$
0
0

Hi,

Are there any BIOS Best Practices for HP G9 Servers (DL360/380, DL560/580) with OS VMWare ESXi 6.5

thx


ML110 G6 - Latest Bios

$
0
0

We like to upgrade this server with 4x 4gb memory, but the server wont start with our new modules.

we like to update the bios for this problem but i cant download it on the website.
can anybody give me a download link for this bios?

Server model - Product ID?

$
0
0

Greetings,

I'm having an issue figuring out my server model and by using server serial number in http://partsurfer.hp.com/search.aspx nothing pop ups.

In ILO I can see: Product ID - 755262-B21

 

Is this it?

Thank You in advance.

HP PROLIANT ML350 GEN 9 ET WINDOWS 2012R2

$
0
0

Bonjour,

J'ai un petit problème pour démarrer l'installation de mon serveur HP Proliant ML 350 GEN9 avec Windows 2012R2.
Au démarrage je clique sur F10 pour le provisioning.
Quand j'arrive au moment de l'installation du système il ne trouve pas mon iso de Windows 2012 R2 que j'ai copié sur ma clé usb de 8 Go formatée en NTFS. C'est bien le fichier iso que j'ai mis.
J'ai même essayé avec une clé bootable Windows 2012 R2 mais c'est sûr que la ça ne peut pas fonctionner.
Pourtant le nom de la clé est visible lorque je rafaichis.
Il me met comme message  qu'il n'y a pas d'iso.
Quel chemin puis-je taper à la main dans la zone de recherche.

CAN I USE A HOT PLUG DRIVE IN THE ENTRY LEVEL PROLIANT DL20 SERVER

$
0
0

CAN I FIT 

HPE SKU of DL20 Hard Drive: 658079-B21 2 TB

 

IN 

HPE SKU of DL20 Server :829889-B21

 

OR AM I LIMITED TO NON HOT PLUG LFF DRIVES.

 

 

INSTALLING WINDOWs 7 ON DL20 ENTRY SERVER 829889-B21 - POSSIBLE - EASY?

$
0
0

IS IT POSSIBLE TO INSTALL WINDOWS 7 ON THE PROLIANT DL20 829889-B21 SERVERs?

IVE NOTICED THERE IS LITTLE DRIVER SUPPORT VIA THE HP WEBSITE.

 

HAS ANYONE TRIED? OR RECOMMEND DOING THIS?