Good Morning.
I would like to know if it is possible that this board works with a power supply of a 800W PC. I have no experience with servers and I am afraid that there are additional control connections that do not have and can not be started. The idea is to buy this second hand plate.
ProLiant ml370 g6 / dl370 g6 606200-001
I am not clear if they are exclusive / special power supplies by additional controls.
I would like to do with such a system, respecting processor configurations, memory .., but the question is whether it will boot with the aforementioned source and placed in a large enough PC box.
Thank you for your time in advance.
A greeting.
Angel
ProLiant ml370 g6 / dl370 g6 606200-001
Proliant ML150 G9 Raid controller upgrade
i have an ML150 G9 with HBA h240. I want to upgrade this to a faster controller. Will the P440 fit and work?
Cannot Install hp smart Storage administrator on Windows Server 2016
Cannot Install hp smart Storage administrator on Windows Server 2016
DL380 G7 Code 351 ACU Error
We have a DL380 G7 with a p410i array controller. It has two arrays. On in a raid 1 (2 72gig) and one in a raid 5 (4 300gig). The raid 1 has the server OS. The raid 5 is for data storage. A drive was removed from the raid 5 and replaced with a new drive. The server rebooted and failed to complete post. It would stall on the Proliant screen with about 5% of the progress bar not completed. After much troubleshooting, we pulled a hail mary and replaced the drive in the array a second time and decided to let the post stay stalled. After about 15min (not the shortest or longest time), we finally got past post and windows loaded.
In reviewing the HP Array, I see the attached screen and this is where I need some guidance:
Code 351 - Smart Array P410i in Embedded Slot Cache Status Problem Detected. The cache on this controller has a problem. To prevent data loss, configuration changes to this controller are not allowed. Please replace the cache to be able to continue to configure this controller. ACU is unable to configure this controller.
I have been searching the web and I am not seeing anything specific to this code. Wondering what exactly happened and how to repair. Afraid to turn off again in case it won't come back online. Hoping someone on this forum has seen this before and can provide some suggestions. Any advice would be appreciated.
Will creating an array delete data on HDD?
Hi, I had a custom built windows 2012 server with a couple of drives. I have a 4TB with some data that i'd love not to loose. Bought a ML30 Gen9 and would like to use the drive (with its data of course). Will using a drive to create an array erase the data? Is there any way I can keep the data in the drive? The drive was a simple volume that I created in the Windows
TLDR: Have a drive with data that I would like to add to my ML30, will i loose the data?
freezing for DL380 Gen9
hi
can get help for my problem please ?
I have new server DL380 Gen9, this server was working normally after installing windows server 2012 R2 on it and working normally for one week, but now after restarting the server its can not boot just frezzing in progress 18 percent.
so if there are any one can help me to resolve this problem i will be very thanks
DL380 Gen6 : EventID:1204 Drive Array Accelerator Status Change.
Hello Guys,
I have a DL380 Gen6 server. In the event log on windows server(x86), I can see the 1204 messages as below.
EventID:1204 Detail:Drive Array Accelerator Status Change. The array accelerator board attached to the array controller in Slot 0 has a new status of 4. (Accelerator status values: 1=other, 2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled) [SNMP TRAP: 3038 in CPQIDA.MIB]
EventID:1204 Detail:Drive Array Accelerator Status Change. The array accelerator board attached to the array controller in Slot 0 has a new status of 3. (Accelerator status values: 1=other, 2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled) [SNMP TRAP: 3038 in CPQIDA.MIB]
According my googling, the event can be sloved after firmware upgrade or replacing a battery.
I'm not sure that is correct. if you have a solution, please let me know.
Thanks.
How do I get a license key to enable raid on my p222 raid card?
Hi, I just got a new used G8 server and the p222 raid card won't enable raid 5 or 6 without a license. I was windering how do I get the license. What's the cheapest way. I just want to use a normal raid system.
Thanks,
Charles
No extended space in the current Logical drive-RAID 5 containing 5 x 300GB 12G SAS drives
Hi,
We have a ProLiant DL360 Gen9 with a Smart Array Controller containing 5 x 300GB 12G SAS drives configured in to 1 logical drive using RAID 5. I have added 3 new drives of identical type the the first 5 and want to use it to expand the size of the current RAID array. After adding such drivers using the HP Smart Storage Administrator, in Linux (Redhat 6) using parted or gdisk , there is no extended space in the current ogical drive.
Here is the Before and After results in my server using command gdisk /dev/sda
Before:
Number Start (sector) End (sector) Size Code Name
1 2048 2099199 1024.0 MiB EF00
2 2099200 4196351 1024.0 MiB 0700
3 4196352 37750783 16.0 GiB 8200
4 37750784 2343486010 1.1 TiB 8E00 Linux LVM => note that the started sector No 37750784, with current size = 1.1 TiB
After:
Number Start (sector) End (sector) Size Code Name
1 2048 2099199 1024.0 MiB EF00
2 2099200 4196351 1024.0 MiB 0700
3 4196352 37750783 16.0 GiB 8200
4 37750784 2343486010 1.1 TiB 8E00 Linux LVM
Any idea so to fix this issue?
Thx in advance,
Trung
Moderator Messsage: This post was moved as a new Topic from Expand RAID 5 with HP Smart Array P440ar Controller
HP SAS EXPANDER 12 GB CARD 727250-B21
We currently have an HP DL380 Gen 9 server with a P440ar Raid controller. The right most bay is filled with 8 SFF SAS drives with RAID 5 configuration. The server works as a DC and fileserver and it needs more space now.
So Please help me for expanding 8 more SFF drives into the remaing cage areas, I think we need:
1x 768857-B21 DL380 Gen9 8SFF Cage Bay2/Bkpl
1x 12Gb DL380 Gen9 SAS Expander Card
8x SAS SFF drives of my choosing (Probably 1.2TB HPE drives)
I also want to keep the original 8 drive with Raid 5 which is already confiugred . The additional 8 HDD drives will added in the server.
So main concerns:
Because after installing the sas expander card my current 8sff hard disks will be connected to sas exapander card and card will connect to p440ar raid controller so:
Q1: After installing HP SAS 12GB expander card Shall my current raid5 will be destroyed /shall i lost all of my data?
Q2: After installing the extra 8sff hard disks can i add them in current RAID 5 which is already configured?
HP SmartCache still active on some drives after removing and disabling HP SmartCache
I've been using HP Smartcache on our HP DL380p Gen8 servers for about 2,5 year. After activating HP SmartCache (on 5 drives) i've never changed the configuration. Recently our RAID-battery was in a bad state so the HP SmartCache has status Destroyed. Because I wanted to add one more drive to the RAID-controller and therefore I need to redesign the HP SmartCache configuration, I deleted all SmartCaches and disable HP SmartCache on the controller. Next I shutdown the server, replaced the battery and start the server again. Once in the OS I re-enabled HP SmartCache but I was only able to activate HP SmartCache on 2 of 6 drives. I canceled the proces of re-enabling HP SmartCache (so it was disabled again) and checked the array overview. There I found that 4 of 6 drives has still the word "(Cached)" behind the Array Name, with status Destroyed.
I cannot find a way to remove the 4 caches. I removed them in front of disabling HP SmartCaches, but it's not removed totally after all. When I enable HP SmartCache (without creating caches) and go to the SmartCache overview, it says that there are no active caches.
I've also erased the SSD which is used for caching. The RAID-Controller is HP P420 embedded.
How can I solve this problem?
Proliant DL380 Gen9 - smartarry P840- SW RAID10 vs HW
Hi,
For RAID10, does it make a Difference difference whether i use SW (mdadm) or HW (smartArry P840)?
My server has 3 vm 2 File servers and one ownCloud server.
I am thingking for my current usage, and RAID10, the smartarray card may become more of a hassle than a benefit. I find it a hassle since:
1- i don't have control over it from within the OS,
2- As far as i know, i have to always boot to make any change
3- I don't really want to learn yet another tool/HW
4- Finally, though it is extremely rare, if samrtArray breaks down, it is harder to recover from it.
Any thoughts or numbers on this, would be helpful...
thanks,
HPDL380G6 both raid 1 HDD amber light
Hi,
Any one can guide what should i do if both of my HDD under the RAID1 now in amber light.
Can the data still be recover by replacing to bay 3 first ?
physicaldrive 1I:1:3
Port: 1I
Box: 1
Bay: 3
Status: Failed
Last Failure Reason: Hardware error
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPD7
Serial Number: 3NM2BTHK00009751T78X
Model: HP DG146ABAB4
Current Temperature (C): 47
Maximum Temperature (C): 49
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
physicaldrive 1I:1:4
Port: 1I
Box: 1
Bay: 4
Status: Failed
Last Failure Reason: Write retries failed
Drive Type: Data Drive
Interface Type: SAS
Size: 146 GB
Rotational Speed: 10000
Firmware Revision: HPD7
Serial Number: 3NM2E8KC00009801H6BJ
Model: HP DG146ABAB4
Current Temperature (C): 48
Maximum Temperature (C): 51
PHY Count: 1
PHY Transfer Rate: 3.0Gbps
HP Proliant Gen8 SD-CARD issue - iLO diagnostic
Greetings,
I hope you can help me because I am experiencing an issue regarding the internal SD-card reader.
The main use of this part of the hardware is to boot a SSD which uses the ODD SATA Port. Once the SSD loads, the SD-card is not load anymore, until a server reboot (almost never).
Everything was working properly until this weekend when, suddenly, the server went powered off and stucked at boot point. Then I checked the iLO Diagnostics panel and I found this:
"Controller firmware revision 2.10.00 Embedded media manager failed initialization".
Well, I did a bootable USB to keep the server working but I really want to know where can be the problem, because it is really strange if it was broken "by use", when the "use" of the SD reader is, almost, 0.
Thank you so much for your help!
Update drive firmware
I have a ProLiant ML350 G6 that I replaced a failed drive in and Smart Storage Administrator advises me to update the firmware on the drive. I have a P410i array controller and the drive in question is a model DF0450BAERH. I found a download for the drive:
I placed the downloaded .exe file into the swpackages subfolder of my SPP, but when I run SUM, the firmware update for the drive does not show up. What am I doing wrong?
Thanks for any assistance.
How to install Oracle Linux 7.1 on HP DL 160 G9
Hi, would HP provide a step-by-step installation guide for Oracle Linux 7.1 on DL 160 G9? I'm trouble:
1) to identify storage (seems Oracle Linux see individual drivers instead my Raid 1 virtual disk)
2) cannot connect network during install (eno1 is not wired - but it is!)
3) default graphics install makes video weird, like a StarWars entrance story tell...
Your help will ge greatly appreciated.
Edson
Proliant DL 20 - INSTALL VMWARE WITHOUT SD CARD
Hello, i purchased a Proliant DL 20 with 2 disk 1tb, for raid 1 with onboard raid B140i.
i would like install pfsense 2.3 with or without vmware Esxi.
do i need a sd card for install vmware? is better than ssd? can i used a ssd disk?
could i install vmware without sd card?
kingston's sd card run in a DL 20? or only hp's sd card??
best regards
No DHCP for onboard NIC after PXE
I am trying to use FOG to image several Proliant Servers. When I boot the server, I receive the initial PXE menu from FOG, however, if I attempt to register the system, download an image, or create an image. The server will attempt to get a new DHCP address and fail with the Onboard NIC. I can install and add-in NIC and it will work fine, however the onboard always fails. I've gone through the BIOS looking for anything that might prevent it from getting a DHCP but can't see anything that would prevent it.
Has anyone run into this problem before. I get it on Proliant Gen 5 and Gen 8 servers.
Thanks
kg
How to check warranty of hpe servers using scripting
i have to find out warranty end date of HPE servers of more than 700, but it is very difficult to find out warranty end date of each and every server manually, So I want to know is there any other way to find out warranty end date using some scripting or something else, So that it will not take much time
If anyone knows please reply here as soon as possible
HP DL380 G3 iLO mac adress is 00:00:00:00:00:00
Hello. I was given a server for small projects. MAC address of the ILO is all zeros. How to fix this trouble?
Thank you.