Hello,
We have an DL180 G5 with Smart Array P400, and with 2 RAID5 arrays on it.
# hpacucli controller slot=6 ld all show
Smart Array P400 in Slot 6
array A
logicaldrive 1 (3.4 TB, RAID 5, Ready for Rebuild)
array B
logicaldrive 2 (199 MB, RAID 5, OK)
logicaldrive 3 (9.1 TB, RAID 5, OK)
we had a failed drive which we replace and that initiate the rebuild for array B,
but now we have array A stuck on "Ready for Rebuild" for few days now.
If i restart the machine, the rebuild process will start again, but will stop after 1-2% of progress.
All the PhysicalDrivers are ok
# hpacucli ctrl slot=6 pd all show status
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 750 GB): OK
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 1 TB): OK
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 1 TB): OK
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, 1 TB): OK
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, 750 GB): OK
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, 750 GB): OK
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, 2 TB): OK
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, 2 TB): OK
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, 2 TB): OK
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, 2 TB): OK
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, 2 TB): OK
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, 2 TB): OK
when runing show config detail I see this message for array A
Parity Initialization Status: Initialization Failed
# hpacucli controller slot=6 show config detail.
Smart Array P400 in Slot 6
Bus Interface: PCI
Slot: 6
Serial Number: P-
Cache Serial Number: P-
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: E
Firmware Version: 7.22
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 1 secs
Surface Scan Mode: Idle
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Enabled
Total Cache Size: 256 MB
Total Cache Memory Available: 208 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Array: A
Interface Type: SATA
Unused Space: 0 MB
Status: OK
Array Type: Data
Logical Drive: 1
Size: 3.4 TB
Fault Tolerance: 5
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 64 KB
Full Stripe Size: 320 KB
Status: Ready for Rebuild
Caching: Enabled
Parity Initialization Status: Initialization Failed
Unique Identifier: 600508B100104B39565732304637000D
Disk Name: /dev/cciss/c0d1
Mount Points: None
OS Status: LOCKED
Logical Drive Label: A06CBE10PAFGL0K9VW20F75A11
Drive Type: Data
How can i return into a healy state of the RAID ?