Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

I need to change the 600 GB SAS dique on Raid 10 by 1TB without losing data

$
0
0

HI ,

we have a  with Raid 10 and I need to  raplace the 600 GB SAS disks by 1TB disks without losing data,

please  what  is the best way  to  do  that ?

HP DL380G7


HD to SDD upgrade

$
0
0

Hi,

I have an HP server presently running HP's  EG0450FBLSF HP 450-GB 6G 10K 2.5 DP SAS hard disc drive.

I would however like to clone this across to an SSD for a I/O speed increase. I would like to know what spec of SSD would suit, in particular the power connector on this existing drive is not the standard L-shaped modern SSD/HDD profile, but a series of pins.

Can I swap the 2.5 HDD out of the 'cassette' thing it sits in and replace it with an SSD?

Kind regards,

Damian 

Single fan failure on a DL320e G8

$
0
0

We are facing issue with Dl320e Single fan failure and found one of the fan from pair of FAN1 is not working, its getting keep restart, how can i able to use the system until get the part replaced. 

Replacement for a hard drive model BD0728A4C4?

$
0
0

Hello,

Can one of the experts here verify that the drive pictured is an acceptable substitute/replacement for a BD0728A4C4 drive in our server?

 

problems with ILO adapter on ML 350 G4p

$
0
0

Hi,
we have a ProLiant ML 350 G4p which is still running fine. But now we got trouble with the ILO adapter. I'm monitoring the accessibility of it with a monitoring software (ServersAlive).
It just complained that the adapter is not accessible. I found the following in the event log (ilo is now accessible again):
Data Frame - Event Log Page

Caution  iLO  [NOT SET]  [NOT SET]  1  iLO network link down.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Informational  iLO  [NOT SET]  [NOT SET] 7 iLO network link up at 100 Mbps.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.
Caution  iLO  [NOT SET]  [NOT SET]  1  Power restored to iLO.

 

Can anybody help me what "Power restored to ILO" means ? The server itself is running fine. And why is no date/time logged for the events ?
Thanks in advance.

Bernd

HP ProLiant MicroServer G8 - Hynix Ram

$
0
0

Hello,

I found a very good offer of used Hynix ram for my server. The guy asked me to make sure that, those sticks are supported by my server. I did my reasearch and specs look like they fit to my system.  Do you think they will be supported ?

HYNIX: 8GB 2Rx4 PC3-10600R-9-10-E1 HMT31GR7BFR4C-H9 D2 AE ECC

DL380 Gen9 Insight Diagnostic, cannot save to USB stick

$
0
0

Hi all,

Currently facing an issue whereby I am trying to save the logs from Insight Diagnostic to a USB stick.

USB stick was FAT32 format.

It can detact the stick, however when i try to save, it mention error "An error occurred while trying to save the file. Please check your media and try again" .

Any suggestion that I can try?

Thanks and Regards,

Low

gen9 -> centos 설치버전 문의

$
0
0

DL380 Gen9에 

CentOS 7.0

CentOS 6.6

Intel Xeon Processor E5-2600v4 Series

CentOS 6.7

CentOS 7.2

이렇게 Minimum Supported CentOS Updates 라고써있는데 이게 무슨 말인가요?

이거 말고도 더 설치되는 버전 있나요?


HPE ProLiant DL380 Gen9 vibration tests

$
0
0

Hi,

I am looking for shock or vibration test values for the HPE ProLiant DL380 Gen9 ? I could not find relevant information in the prduct specifications.

Thanks,

 

HPE Proliant DL 180 G6 - issues

$
0
0

Hello.

1. How to install hpacucli on debian 8? For monitoring (hp smart array p212)

2. Does this machine have iLO / IMPI?

10 Drives with a DL360 G9 & P440ar

$
0
0

I'm trying to use 10 drives in a DL360 G9 with a P440ar & the 2 drive expansion bay for the purpose of using the 2 extra drives as SSD Smart Cache for my data drives.

Drive Bays 1 to 2 - Operating system

Drive Bays 3-8 - Data Partition

Drive Bay 9-10 - SSD Smart Cache for the Data Partition

I've been back and forth with support for a couple of weeks, they've sent out a new cable which is a Y cable which was meant to let me plug 2 of the backpanes into a port on the P440ar, freeing up a port for drive bays 9-10. This cable did not fit the P440ar and is only compatable with the P840.

I've tried using the onboard B140i for the operating system, but it doesn't support SAS drives. It supports the SSDs but it won't let me smart cache them for the data partition. So that's not an option unless I buy some SATA drives to install the OS on.

My next thought was to use a raid expansion card, but I've been told its not compatible with a DL360 G9. Can someone confirm this?

What are my options?

Buy a P840 and use the Y cable I've been sent

Buy another P440 and plug bays 9-10 into it and use this for the operating system.

Can I use a 2nd hand P410 PCI RAID card, or similar, for bays 9-10  in a DL360 G9, I dont care if its not officially supported, will it work?

I'm trying not to spend more than I need to, I'd like to avoid buying a P840 or P440 just to use these extra 2 drive bays if possible.

Thanks

Processor Support for HP Proliant ML150 G6

$
0
0

Hi,

I have recently aquired one of these machines for some a basic Virtualisation lab for my studies. I am curretly looking at options for upgrading the CPU. 


My server is currently equipped with one XEON E5502  processor (1.83ghz). I have looked into the following two options for upgrade

1. Purchase another XEON 5502, and run in a dual-cpu configuration

2.Purchase two new cpus, that are more powerful. I have been looking at purchasing two INTEL xeon E5540 or E5530 processors, and use these instead.

My question is can two E5540 or E5530 processors be used in this server, and is there sufficient power to do this? 

Many thanks in advanced

Greig

ML350 G5 with 6-port LFF Backplane - Where does the I2C LED wire connect to from the Backplane?

$
0
0

Hello,

 

I have a ml350 G5 with a  6-bay SAS/SATA large form-factor (LFF) hard drive cage (416456-001 ) that uses a 6-port SAS/Sata Backplane (365668-001 ) .  The Backplane has the 2 SAS connectors that go to the controller and a 3-pin I2C connector for LED controll.  Where does the 3-pin I2C connector plug comming out of the backplane connect to?  I assume it would of been on the motherboard (original controller is embedded), but I do not see where and I have checked the server manual and motherboard connector diagrams and I could not find it.

 

Any help is appreciated.  Thanks!

Configuration required to install NGFF M.2 SSD + M.2 to PCI - E Converter card

$
0
0

2 of our HP DL 360 G7 running Linux are running on 8 disks and running out of free space (post housekeeping). There are no empty slots available to add more disks to the server. I would really appreciate if I could get suggestions to expand storage capacity for this box.

One option, I am considering is to add a 500GB NGFF M.2 SSD + M.2 to PCI - E Converter card. But, this will not allow me to add available space to existing RAID sets and hence not provide any redundancy. Would I need to add a RAID controller card? If yes, then having only 1 disk will only allow RAID0 (Stripe set) which will also not allow any redundancy.

Any suggestions please...
Thank You!

How to set different Queue Depth value per ports?

$
0
0

Hi, Guys,
I have a DL380 runing Redhat Enterprise Linux 7.

I would like to connect with different multiple disk storage from DL380 via fibre chanel using "HPE 2port 16Gb Host Bus Adapter" .

In addition, I would like to set different queue depth value per ports. (eg. QD of port0 = 30, QD of port1 = 1)

Is there any way to set queue depth value per ports ( or LUNs)?


Flashing RED System Health LED ML110 G7

$
0
0

Hello every one ;

I have a problem with my server when i reboot it the LED System Health is Flashing Red ; and server block at this state until press a power button to shutdown it or a could restart

they are any solutions to this Issue

thanks for alll

Warning: HP_Smart_Array_Monitor:Surface Analysis Pass Information

$
0
0

This warning message is randomly logged to my HP Proliant GL380e G8 storge servers.  They do not have Windows OS installed on them.  The iLO doesn't show any errors in the IM log nor the Storage Information tab.  Is this soemthing to be concerned about?   How can I resolve?   Thank you

Smart Array P440 controller fails updates

$
0
0

Hi folks,

I've got a new server DL180 Gen9, and I'm trying to update the BIOS in the P440 Smart Array controller. The current BIOS version is 5.04, and the current available for download is 5.52. The reason I want to update the BIOS, is a nagging Windows event (about 20000 entries per day), that there is a failed IOCTL, which not uncommonly implies that there's a hardware problem. At least, I would like to eliminate a buggy BIOS as the cause. And I will not put the server in production, until the most serious errors are gone from the event log.

The problem is, the update always fails when I run the update package (cp032905.exe). I've tried several times, always with a reference to the engineering log. I've also tried Smart Provisioning at boot time, but Smart Provisioning cannot contact any HPE servers (seems to be the normal state of affairs), so no luck there.

I would be grateful to get any advice how to solve the situation.

Best regards,

Pete

 

DL360 G7 fan surging

$
0
0

I have a new-to-me DL360 G7 and everything is working fine.  What's weird is the system fan seems to surge.   It starts out quiet and then get mildly louder.   Not like start-up loud...just a little bit louder.   This cycle continues about every 5 seconds.

Any thoughts?

UPS Question

$
0
0

I have a CyberPower UPS and am using PowerPanel running on a virtual machine on my DL360P. I have the setting to shutdown the ESXi host after 30 seconds on no power and email me.

This works 100% but the issue I have is how do I get it to restart once the power comes back on? When I tried it I had to manually push the power on button.

Viewing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>