Add a HDD in a Proliant ML30 with a RAID 5 Array

$
0
0

Hi, We have a Proliant ML30 server with an array with 3 HDD in a RAID5, with 2 partitions (system and Data), each disk is of 1TB of capacity. At this time we need more free space, the server can support other SATA HDD (3.5"), How can we add other 1TB HDD to the same array without losing the data?

Thanks in advanced

Regards

TSS-Puebla


HP DL380 G7 Local C Partition Expansion

$
0
0

Dears,

 

We are using HP DL380 G7 server. its loaded with 3 300GB SAS disks configured in RAID 5. now our Local C partition is nearly full. So we want to increase it. I bought 2 new 300 GB hard disks.

Should I rebuild the array for this??

How will I specifically increase the Local C partition? for this if i am doing shrink and extend feature.. will i have data loss??

SPP Gen8.1 contains older HPE Broadcom 1Gb Driver/firm than available, newer version also supported?

$
0
0

Hi,

OS Windows Server 2016 on DL380 Gen8

SPP Gen8.1 comes with this (older) driver and firmware versions;
-HPE Broadcom 1Gb Driver for Windows Server x64 Editions v17.4.0.0(B) (24 Oct 2016)
https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d07f1f998bcc40f2a912f37c7f

-HPE Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions v5.0.0.24 (24 Oct 2016)
https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2ab6d25c9afd48adbc98838d77


When I click revision history I can download and install succesfully these later versions;
-HPE Broadcom 1Gb Driver for Windows Server x64 Editions v20.6.0.5 (25 Sep 2017)
-HPE Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions v5.1.1.0 (25 Sep 2017)

If i navigate to this collection of Gen8 drivers I get the same 'older' drivers.
https://support.hpe.com/hpsc/doc/public/display?docLocale=null&docId=emr_na-c05029449&sp4ts.oid=7271241


I assume the installer has logic to detect if installed on a SUPPORTED server so because this installer DOES install it seems to be 'supported' on a Gen8 server. Also, I think its normal to click on revisions to choose the latest version available.
But because the PSP is an tested bundle my question is, is this later version of the HPE Broadcom 1Gb Driver and Firmware supported on a Gen8?

I would stress the fact that the installer doesn't prohibit the install on a Gen8 server and therefore if used in a mixed Gen8 and Gen9 environment you could accidentally install these drivers on a Gen8.

So are these drivers supported or not? :)

Regards,
Arian van der Pijl

Entitlement Order Number for Microserver Gen10

$
0
0

I have just bought an HP Microserver gen10 for private home use, I am trying to register the product so that I can access downloads but the registration form asks for an Entitlement Order Number. Ther is virtually no documentation with the Server and I have no idea what the Entitlement Order Number is or where to get it.

I am grateful for any help, thank you.

Upgrade Server with RAM and HDD

$
0
0

I have a HP ML350 G8 server, I need to upgrade this with more RAM and disks.

The server have now 48gb ram, 24gb on each CPU and 3x300gb in RAID 5

I have 2x16gb RAM and 3x600gb disks

Where do I place the new RAM? and how do I configure the new disks in RAID 5?

If use see the picture you see where the RAM is placed in the server

HPE ML10 gen9 RAID card issue

$
0
0
Hi,

We have a ml10 gen9 that we have been running with onboard raid for about a year without any issues, we have come to the point where we have ran out of data and need to expand. We have purchased an Adaptec 51645 raid card to expand into and are having issues getting started.

The raid card has been tested on win 2012 r2 and works however we cannot seem to get it to work on our system after many different configurations in the bios and disks.

When we insert the raid card and use UEFI only setting the bios hangs and we get nowhere, when we boot using legacy we get a flashing ‘_’ and gets no further.

We have an intel xeon v5 processor, 32gb ecc ram, intel dual gigabit nic.

We have also ensure that the bios is up to date and is running 1.08.

Any information will be greatly appreciated as we are at the end of the tether after spending all day on it.

iLo remote console

$
0
0

Hi,

 

I have two questions

1. Can we configure MGMT | DATA port on HPE - clearpass using iLO remote console?

2. when we launch the console on iLO webui - it brings up a popup, shows me the below window and the it seems to just close and do nothing else

please advise.

 

Thanks

DL360 G10 servers and lack of support

$
0
0

So our company went out and spent 30k on a new DL360 G10. I was looking forward to getting it into our environment but after hours of frustration I'm about to send this thing back.
HP has apparently modified the bios so much that there are no more hardware diagnostics to run to burn it in, and the bios settings to get it to boot to a usb stick don't work.
I've disabled, enabled, uefi, all security options for booting to a usb stick. The deployement software built into the bios won't accept a microsoft iso file to install the OS. It just says verifying, then does nothing and won't let me select the iso file on the usb stick.
Even when I can get it to boot to the usb stick, for some reason I don't have any mouse or keyboard options to use. I've tried usb mouse and keyboard, and even the one on the kvm...no luck nothing works.
I've attempted to connect to the ilo interface to get thru it, no luck.
I've worked with HP products for years and this one is one of the most frustrating ones I've ever come across.
I've tried searching blogs and everything else but apparently there's nothing out there yet.
When I try using HP's site and search specifically for the model and the results I get are for g9's and earlier, which doesn't apply.
Completely frustrated with this new model!!!


DL380 G7, SFF, only 2 things now, missing, got it all but the SPP DVD, that is not sold. it seems

$
0
0

Help please !

Topic: Service Pack Proliant DVD.

Type: Software - System Management Version: 2.65.7.0(21 Apr 2017) Operating System(s): Microsoft Windows XP Professional x64 Edition | View all File name: cp031007.exe (13 MB)

 

why can't we just buy it  outright for cash, or paypal pay.

it's not sold , and looked all over the web,  nobody sells it?

I tired the navigate the HP BUY pages and get lost in seconds.

1:BUY  SPP DVD , zero support

I'd be happy to sign a NDA.  I will not share it with any one.

 

1 Disk, 1 user, 1 server, one serial number.

why must it be so hard? or am I just lost in the soup.

thanks for any help at all , even the most small.....

retried tech me. (use: media server , home)

 

windows server 2016 drivers for DL160 G6

$
0
0

hi
where can i get drivers for DL160 G6 on windows server 2016 ?

I already looked here: https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=3884345
but there are very few drivers.
for example, there is no "system controller driver". i need it to install "Insight Management Agents"
when i install "Insight Management Agents", i get error:
"The software is not supported for installation on this system.
The installation program couldn't find the appropriate system management controller driver which is required but is not currently installed.  Please install the appropriate system management controller driver and then rerun the setup program.
Press 'Close' to exit Setup."

 

thanks in advanced

Windows could not prepare the computer to boot into the next phase of installation

$
0
0

I have an HP Proliant MicroServer. Bios is set to use Raid. The Raid setup is configured for Raid 10 using four 2 TB drives. I see the drives in the Raid controller setup. When I try to load windows, I get to the point where I need to reboot and i get the message, "Windows could not prepare the computer to boot into the next phase of installation. To install Windows, restart the installation." I have tried multiple sized partitions. I have formatted the drive prior to attempting the OS install. BIOS version 041. AMD Turion II Neo N40L Dual-Core Processor, Speed 1500MHz, core count 2.  Memory, 6GB.

This happens for Windows Server 2008 R2 as well as Windows Server 2012.

Any help would be appreciated.

DL185 g5 fans problem

$
0
0

Hi,

 

I have a DL185 g5 server and the mobo broke, so I bought a refurbished one.

Now when I start the server, it says that don't detect any fan (it says 6 fans but I only have 4). 

I can not eather enter on the boot menu or bios to update firmware.

 

Someone can help?

 

Regards

installing windows server 2012 r2 on DL360 Gen9

$
0
0

Having problems getting it to install. Tried Intelligent Provisioning, but when it attempts to install, get an error that says "setup was unable to create a new system partition or locate an existing system partition".

Tried to create a uefi bootable drive but not having much luck with that either. 

Open to any suggestions.

Server Slow - ML 350 gen 9

$
0
0

Server ML 350 Gen 9( OS : Win 2008 R2) getting very slow after warranty repair ( MB Changed).

Current Status:

1. OS: Windows 2008 R2 Ent. installed with latest device drivers and possible updates.

2. RAID; Kept prior settings ( with out RAID Re-build).

Mixing Different RAMs in HP Proliant DL360 G6

$
0
0

Hello, 

I have my Proliant Server. My question is, is it possible to mix RAMs with the following specifications? 

RAM #1 >> 2GB 2Rx8 PC3-10600R-9-11-b0 

RAM #2 >> 4GB 1Rx4 PC3-10600R-9-11-C1

RAM #3 >> 4GB 2Rx4 PC3-10600R-9-11-J0 
finally, What is the meaning of the numbers 9-11-J0, C1 & b0? & why they different? 

Thanks in advance


HP HBA221 Hotplug external Tapedrive

$
0
0

Hello, we are using a Proliant ML350 G6 with an internal HP HBA221 SAS adapter.  We have connected an Ultrium/LTO6-Drive externally to this adapter with SFF8088 cable. The OS is Windows 2008 R2 SP1 - full patched. Is it possible to disconnect the external tape drive without powering down the server? We want to connect the drive to another server-hardware (at the new hardware we have the option to reboot the server without problems). Regards, Jörg

HP Proliant DL180 G6 RAID issue

$
0
0

Hi There!

Just to understand that have a DL180 G6 server which is outdated (I know), and we're just using it as backup server. This server is configured with RAID 6 using the smart array P410 controller and is currently on degrade mode. 

Out of the 12 disks on bay, 3rd bay disk showed it was rebuilding while the 8th bay showed a predictive failure until yesterday. Below seen is the result till yesterday.RAID-P1.PNG

 So, I let it rebuild to see what's happening and then the result showed as below; (as at today)RAID-P2.PNG

 My question is, when I saw the predictive failure itself, I had order for a disk making sure I have everything ready in case of multiple disk failures. 

Now my question is, since the 3rd bay shows that its failed, can I hot-swap the disk while the 8th bay shows rebuilding? Is it recommended or should I wait until the rebuilding process complete.

HP ProLiant DL360 Gen9 > Smart Array P440ar > Cache Module Status > Degraded

$
0
0

Hello Guys,

My Raid battery status just went failed last week, I order a replacement and I was able to get it into the server this morning but unfortunately the status still failed after replacing the new battery.

Just wondering what is the next troubleshooting step?

 
Controller Status  OK
Serial Number PDNLH0ARH7D0AV
Model Smart Array P440ar
Controller Firmware Version 1.18
Controller Type HPE Smart Array Cache Module Status Degraded
Cache Module Serial Number PDNLH0ARH7D0AV
Cache Module Memory 2097152 KB
Encryption Status Not Enabled
Encryption ASIC Status  OK
Encryption Critical Security Parameter NVRAM
StatusOK

Unable to Configure Raid using Restapi on Gen10 server

$
0
0

Hi,

 

I am trying to configure our new Proliant DL380 Generation 10 hardware using automation.  part of the solution is to configure the P408i controllers with a Raid 1 logical drive using SATA SSD drives, configuring with the REST API, (Note the Restful Interface client).    When using the PUT Method, I get a 200 response, and the configuration shows, however, on reboot the config is not persistent.

 

The drives show as Mixed mode in the GUI, which I am not sure is a red herring, has anyone managed to successfully configure the drives by this method, and know that it is possible?

 

Thanks in advance

Craig

Need help with HP ProLiant ML 150G6

$
0
0

So I have a HP ProLiant ML 150 G6 server desktop, and its missing some parts- I got it from a friend. I does have a power supply, and it has 2 CPU sockets, one of them is already in there, need to find out the other one, but I don't know what CPU it is. I have no ram whatsoever, So I don't know what kind of ram I need. and there is no hard drives in there, but I can supply that assuming it works with any hard drives to date. I think there is 12 ram slots. Any help would be greatly appreciated. 

 

 