Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

By default Embedded B140i controller would work in ACHI mode (No RAID levels)

$
0
0

Can anyone have idea about this alert message when configure BOQ of new HP server

By default Embedded B140i controller would work in ACHI mode (No RAID levels). 'Hamer BIOS Setting' Kit must be selected to enable RAID functionality in Embedded B140i controller.


how to choose right power type for HPE DL server series

$
0
0

How to choose right power core HPE DL serious for example DL380, 360 ...
Mostly I sellect NEW HPE ProLiant Servers offer Flex Slot Power Supplie

HPE 500W Flex Slot Platinum Hot Plug Power Supply Kit x 2

and it show warning message 
" NEW HPE ProLiant Servers offer Flex Slot Power Supplies that come in multiple power ratings to allow you to pick the Right Size to fit your configuration. This provides you with the advantage of reducing and reclaiming lost power. By selecting the right sized power supply you will be providing facilities with a nameplate rating that is much closer to actual power your server uses. In order to select the right size power supply for your ProLiant Server it is 'highly recommended' that you use the 'HPE Power Advisor' located at ' https://paonline56.itcs.hpe.com/?Page=Index' to determine the right size power supply for your server needs.

"

 

DL380 Gen8 System Power 25SFF Fault Detected Error with empty smart drive carriers

$
0
0

I recently recieved 6 of the above listed servers. All of them appear to be running normally on standard workload and during stress tests.

But if i insert empty smart drive carriers (without hard drive in carrier) system shutting themselves down.

The foloofing error appear System critical. System health LED is flashing red.

If i insert HDD in smart carriers servers begins operates normaly.

Is this normal? I think it's really awkward.

I couldn't find out any similiar porblems on HPE forums or on Google.

Please tell me i'm not the only one with this problem :)

HP DL585-G7 NOT POWER ON - LED STATUS No LED except health green

$
0
0

Hi team,

I have HP DL585-G7 server gone to not power ON state.

1.  I replaced the 1.PCI xpress motherboard 2.Power backplane 3.Power supply 4. SPI board.

2. But no luck. i can only see the error code on Base board "88" {note previous it was "EE" after change base board it changed to "88"}

3. I already tried CMOS battery clear and NVRAM clear through system mangement switch.

Can any one help

-Subash Raja

 

Compatible GPU for HP DL380p Gen8 Server

$
0
0

Hi,

I have a HP proliant DL380p G8 server. I need to know which Graphics card is compitible with this server for High performance gaming.

Thanks in Advance

Max internal storage in HP Proliant DL360 G5

$
0
0

I need to know what the max of internal storage in DL 360 G5 is 876 GB or 3.0 TB

ml350 gen6 last service pack

$
0
0

Hi evryone, 

i got an HP ML350 Gen6 and i want to update driver, i want to know which version of spp i can use ? is there a limit version or i can download the last ssp available ? 

 

Thanks

mog54

How to configure the RAID of HP Proliant ML370 tower server Generation 6?

$
0
0

Hi,

How to configure the RAID of HP Proliant ML370 tower server Generation 6?

What is the best RAID I could use? any suggestion?

Thanks..


Adding 2nd LFF cage to HP ML350 gen9 (enabling 16 drives support)

$
0
0

Hi, 

I have HP ML350 gen9 LFF with b140i and 8 LFF cage (765819-425).  I need to convert it to support 16 LFF drives. By my research i need these items to do that:

1. HP ML350 Gen9 8LFF Hot Plug Drive Cage Kit  726547-B21

2. HP Smart Array P840/4GB FBWC 12Gb 2-ports Int SAS Controller 726897-B21 (DOES IT COMES WITH 96W BATTERY and cables required to connect to backplanes??)

3.  2 pcs HPE ML350 GEN9 Smart Array Cable Kit 765650-B21   8xSAS to 2x miniSAS cables

is this purchase list correct? Or i should go with adding SAS expander way?

ML110 Gen9 High fans with SATA AHCI

$
0
0

Hi.

I recently purchased a HPE ML110 Gen9 4LFF and installed ESXi 6.5 on it. using the HPE custom image. I have two LFF disks. Rather than using the B140i software raid, I want to pass the two disks directly to ESXi.

When I set the mode to SATA AHCI in BIOS rather than B140i, the disks are present in ESXi, but the fans continue to spin at a higher rate, as the normally would during boot up. When I switched back to B140i in BIOS from,SATA AHCI and the fans are silent again, but I cannot see the disks in ESXi. Assuming I first need to set them up in some type of RAID first.

My question is, is it possible to pass the disks directly to ESXi whilst keeping the fans speed down?

Thanks in advance.

HP Server Gen 8

$
0
0

Hi, I have a HP server Gen8 and have recently instaled a 3TB drive into the server. When I boot up into server 2016 it only recognises this drive to be 350Gb in size? Please help?

Orange Health light on DL380 G3

$
0
0
All,

I have a problem with a DL380 G3, the problem is that the health light on the server is ornage, however I can see no failed or failing hardware on the server, all the PSU's are connected and I cannot see any internal components un-seated or damaged.

I am running Windows 2003 Standard Edition with SP1 though this will not make a difference, I thought I would let you know.

I have checked the IML log and there are no failed entiries in the log also I have run Insight Diagnostics to find no errors with the system.

So far the server has not crashed and the system has not performed a BSOD

This is a critical server and I have a feeling that booting the box will remove the LED but cannot just perform a rebbot "just in case" any Ideas???

Regards,

Lee Croucher

Will HPE acknowledge Intel ME vulns?

Windows Server 2016 (1709) can't installed on HP Proliant DL380 Gen9

$
0
0

Hi All.

I have a Problem with  the install of Windows 2016 (Vers. 1709). I boot from Intelligent Provisioning, install looks fine. 

But when the Driver installation is done, the Server hung up in HPE Boot Logo.

When i try to install Windows Server 2016 (Vers. 1803 and 1735 Preview Build) there is no Problem.

Server is HP Proliand DL380 Gen9 and Drivers, ILO, etc. are up to date and latest.

Thanks in advance 

BR deffer

 

Doesn’t HPE DL380 Gen 9 have support for ADK 1709?

$
0
0

Hi Doesn’t HPE DL380 Gen 9 have support for ADK 1709 (WinPE 10.1.16299) we have upgrade our SCCM to 1710 and ADK 1709 and we can’t install HPE DL380 Gen 9 anymore, HPE DL380 G8 works fine

Have anybody tried this yet?

We can see WinPE loads but it results in black screen when the WinPE load bars ends


Expanding Raid10 [DL380 G5 / Smart Array P400, FW 7.22 / ESX 5.5]

$
0
0

I have running a P400 with 4x 150GB SAS in Raid10 and want replace the disks with 300GB SAS. My fist question: Is there any chance to to this by just replacing the Disks step-by-step and waiting for rebuild?

- replace Disk1 150GB by 300GB, start, wait for rebuild done
...
- replace Disk4 150GB by 300GB, start, wait for rebuild done
-> Now, can the P400 detect the new size and let me expand from 300GB to 600GB ?

 

Currently there is also another Raid1 with 2x1TB which could be removed temporary, so another way could be:

- remove 1TB Raid1
- add 4x300GB Disks and configure a new Raid10
- clone all data (dd?)
- remove the old Raid10 (4x150GB) and put back the 1TB Raid1
-> Is the controller now re-detecting the 1TB raid or do I need some manual configuration?

 

And then the last big question: If all the data is cloned to the new Raid10 does anyone know if there are some special steps needed to boot up the ESX5.5 installed on that Raid10? Can the volume easly be extended to the new size?

DL380 G6

$
0
0

Hi I am trying to install HyperV a 

Issue is when I try to install HyperV . I reach a screen stating  "Where do you want to intall Hypber-v" with no drives showing.  Error below " We couldnt find any drive to get a storage drive click load driver. 

Any advise what I am mising here?

My server is Proliant DL380 G6.

ty

 

No option for Expand Array after adding disk.

$
0
0

I have an issue trying to add disk space to my Array configured on a P410i raid controller. When I add the disk, the ACU see it, but when I right click the array/disk, I only have options to "Add Spare", or "New Array". Nothing for "Expanding the Array". I slapped the disk in a couple other HP Proliant DL G7 servers with same/simular setups, and I DO have the option to expand. Firmware is same, and all have Cache battery backups. But believe something is not set correctly in the controller configuration. I have tried comparing the configs line by line, but having issues determining what needs setup/enabled. Any advice would be greatly appreciated.

Fake hard disk frames for Gen8-Gen10?

$
0
0

We did some experimenting lately... I was wondering if a non-HPE SSD drive would work in a brandnew Gen10 server (DL380). I assembled the drive with the frame that was supplied, plugged it into the server and got a message from SSA: "Not a genuine HP disk drive, the front panel lights will not operate....blah blah" and a yellow warning sign.

I noticed that the supplied frames did not look exactly the same as the original ones and I changed one frame with another I knew was working. And looka there... the problem was gone!
I also noticed that one frame had one of those infamous golden chinese Q.C. (Quality Control) stickers... Do the chinese manufacture fake disk frames?

Has someone else seen disk frames that do not work? I wonder where they come from... Anyone been on the Shenzhen market lately?

No boot after installing Linux on ML150 G9

$
0
0

Dear all, please help:

Steps I did to install a supported Linux by HPE:

  • Connect the Ethernet cable between the network connector on the server and a network jack.
  • Press the Power On button.
  • During server POST, press F10 for Intelligent Provisioning.
  • Complete the initial Preferences of Intelligent Provisioning.
  • At the 1 Start screen, click Configure and Install.
  • Image of Linux on DVD inserted. Instelligent Provisioning starts installation of SO. Finish the installation, follow the onscreen prompts. 
  • Reboot… System doesn’t start the SO on the hard disk.

Thanks for your help!

Viewing all 10362 articles