ML110 G9 hdd noise

$
0
0

Hello,

I'm experiencing high HDD noise with my ML110 G9. Is there something that could be done to lower the noise?

My setup:

ML110 G9 

HP Dynamic Smart Array B140i Controller - using RAID mode

4x HPE 1TB 6G SATA 7.2K rpm LFF (3.5in) SC Standard  (858594-B21)

Windows Server 2016

Thank you!


Can i setup new os on proliant ml350 g8

$
0
0

Hello every one.

 

I have one question concerning one of my physical sevrer : Proliant ML350 G8, currently ESXI is install on this server with 4 VMs but it is possible to install only a Windows server 2012 for exemple ? I didn't find anything concerning this subject on the internet.

 

Thanks in advance for your reply and have a good day !   

DL360p gen8 STOP: 0x00000080 Uncorrectable PCI Express Error, NMI Hardware Failure

$
0
0

Hi All,

We have 2 DL360p Gen8 servers, both have 2xCPU E5-2630L and 32GB RAM (8x4GB Genuine HP memory), SA420i with 1GB cache.

Installed Windows 2016, updated FW to the latest, installed drivers from the latest SPP

Both servers crash with:

Uncorrectable PCI Express Error (Embedded device, Bus 0, Device 28, Function 7, Error status 0x00100000)

STOP: 0x00000080 (0x00000000004F4454, 0x0000000000000000, 0x0000000000000000, 0x0000000000000000))

I read some troubleshooting steps already and did the following:

Set the memory refresh to Auto
Set Power Mode to static high peformance/disable C6
Removed PCI Raiser Board
Removed SA cache module

NOTHING helps.

Server 1 was configured as AD everything was going fine and all of a sudden after another reboot it refuses to come up.  It just doesn't want to boot to OS, period. Crashes every time Windows starts loading.

Server 2 just crashed upon restart but is booting up on the second try. I'm afraid it will start crashing all the time as well.

Attached is the screenshoot with IML.

Please help, I'm going insane...

Software update

$
0
0

Hi ,

I have an array 5 configuration with a rescent drive failed , also have array configuration utility software (web based) 8.40.4.0 version , and now there is newest 9.40.12.0 version, my question is :

Could we update from 8.40 to 9.40 without facing problems ?

 

Thans a lot !

Following Windows 10 Fall creators update, boot hangs

$
0
0

I run an HP Proliant Server DL20 Gen9, with a windows 10 OS, which has been fine upto the 1709 Fall Creators update. This update loads, installs and after reboot, the server just hangs, showing the light blue window on a black background for ever ( upto 2 days ) and never shows the small circle of dots rotating as in normal boot. I have to power off using power button, and reboot to get back to the previous windows but I cannot stop it trying to install it again ! 

Any suggestions on fixing this ?

Thanks

Tony

Smartcache writeback Perfromance

$
0
0

Hello,

I'm upgrading my current server ( ML 560 g9) and i though about using smartcache with writeback to improve overall server perfromance. Unfortunatelly there is not enough data on hpe pages / and google .

I wonder whether anyone here is using this tech ? 

I though about this setup ( for sql server )

22 x 10k SAS raid 10 ( p440ar 2GB controller) 

2x800G ( raid1) SAS SSD MU As smartcache writeback.

Thank you.

DL365 (G1), Quickspecs: RAM & HDD capacity?

$
0
0

I believe that I've located the correct Quickspecs document for my 1st Generation Proliant DL365 servers. And, if I'm reading the spec's correctly:

  • the maximum memory supported by that generation of DL365 is 32 GB and
  • the maxiumum internal storage is 6x146 GB.

However, the DL365's in my lab currently have:

  • 4x8 GB plus 4x4 GB (48 GB) of RAM and
  • 6x300 GB SAS HDD's.

So my question is: Is this the correct set of Quickspecs for the First Generation DL365? And, if these are the correct Quickspecs:

  1. What is the maximum memory that can be installed and recognized and utilized by the motherboard?
  2. What is the largest SFF SAS/SATA HDD that can be installed and utilitized by the P400i RAID controller [w/ BBWC and 256 MB]?
  3. Can I reliably replace the 2.6 GHz dual-core AMD 2218 with the 2.3 GHz quad-core AMD 2356 (specified at the top of Page #2)?

TIA!

ML370 boot problem

$
0
0

Hi, we have a ML370 server with Novell netware 5 OS in our office, it was working correctly, since yesterday during boot up on checking storage stop on following line:

Slot Port Id Lun

00    1      0    0

 

there are 2 scsi hard disk.

i need yor help for troubleshooting the error, i didn't find any help related in websites. i think solving this problem need exprience from many years ago..


ML350G5 E200 - failed drive problem

$
0
0

Hi all,

I have a problem in old ML350G5 server as follows:

=> ctrl slot=0 show config

Smart Array E200i in Slot 0 (Embedded)    (sn: XXX     )

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 2 (279.4 GB, RAID 1, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)

   array B (SATA, Unused Space: 0  MB)


      logicaldrive 3 (2.7 TB, RAID 5, Interim Recovery Mode)

      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 1 TB, OK)
      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 1 TB, OK)
      physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 0 MB, Failed)
      physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 1 TB, OK)

   unassigned

      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 1 TB, OK)

The drive in 2I:1:7 has failed, controller did not detect new drive when it was inserted in bay 7. Rebooting server with new drive inserted did not help.  It might be some backplane issue.

As it's remote location I've instructed the local person to insert the new drive into bay 4.

But I'm not abe to modify this array:

=> ctrl slot=0 array B add spares=1I:1:4

Error: This operation is not supported with the current configuration. Use the 
       "show" command on devices to show additional details about the
       configuration.
Reason: Array is transforming
=> ctrl slot=0 array B modify drives=1I:1:4,2I:1:5,2I:1:6,2I:1:8  

Error: This operation is not supported with the current configuration. Use the 
       "show" command on devices to show additional details about the
       configuration.
Reason: Array is transforming

memoire sur serveur prolian g6

$
0
0

bonjour

je suis a la recherche d information pour faire une extension de memoire de 4 go sur un serveur proliant g6 ml350 qui a deja deux barette de 2go 

quel type de memoire ?    par deux ou seul ?

 

merci

conrep on a PROLIANT XL170R G9

$
0
0

Can we use conrep to extract & apply RBSU setting on the XL170R G9's ?

Looking at the scripting toolkit (v11.05) there's no conrep xml file for this particular model.

Thanks.

DL380 G9 with non-HPE P100

$
0
0

Hi,

we are experiencing some problems running a non-HPE P100 GPU in a DL380 G9.
The Server is equiped with the high performace fans, the GPU enabler kit and two 1400W power supplies.

The fan do not speed up (according to the iLo) to more than 15%, even if the GPU is alreay reducing speed by it's high temperatur (82°C and more).

Is there anything more to do, to run non-HPE P100 GPUs in the DL380 G9?

Thanks for your help.

Proliant G10 Partitions

$
0
0

I have a Proliant G10 and need to partition the harddrive.   It is 1.2 TB total space.  We create it with Raid 6 ADG.  We need one Partition for the operating system at 200 GB with the rest of the space to the remaining parttion.  With the G10 I am unable to create the partitions with these deminision.  Although when using the G9 we were able to create it this way.  Both are usinge 2012 r2.

Any help would be appriciated

Thank you 

HP ML310e Gen8 V2 HP SUM Cannot launch hpsum_service_x64

$
0
0

Hello to all,

i've this problem. Trying to update server with SPP 2017.04 ( i've seen it's the last FULL Gen8 SPP ).

With 2015 and 2016 SPP i had no problems.

I've prepared USB bootable key and when Launch as Admin logged in the launch_hpsum.bat , after few seconds a command message box pop up with

"Error: Cannot launch hpsum_service_x64.exe locally. Reason: General failure. (Co
nnection failed: This can happen if ports 63001 or/and 63002 are in use by anoth
er application, or blocked by firewall settings. Please check the troubleshootin
g guide to know the application that is using the ports. To unblock the firewall
 settings, please restart HP SUM with open_firewall option.)"

I've disabled temporary Win Firewall, ESET Firewall, Stopped IIS Service, Checked another instance with netstat -ano  without solutions.

What wen wrong? I can use that SPP on my Gen8 ?

Regards. Andrea

P.s. Windows 2012 R2 ROK Running

End Of Service Life (EOSL) DL360 G5

$
0
0

Hi guys. I've searched everywhere but I coulnd't find an official answer or so.

I'm looking for information of End Of Service Life for several HPE products.

DL360 G5

DL360 G6

DL385 G2

DL380 G5

DL585 G2

There's a lot information online about these products but everyone of them are wrong.

How do I know this? We have a lot of these servers under support contract, right now we are in negotiation for this year.

Sadly for us, HPE doesn't list this information, and I couldn't get it from my account manager, in essence HPE makes more difficult to sale the need it upgrades to our bosses.

 

Thanx in advance


How to get percentage status during Raid5 rebuild process ?

$
0
0

Hello everyone

I have HP ProLiant DL160 Gen9 with raid 5. What i need is to get the RebuildCompletionPercentage from the iLo api. I have tried several http get queries but non of them worked . Also if i browse iLo web interface percentage completed is not shown during rebuild only "Status     Degraded(Rebuilding)  " appears. iLo version is 4

 

Thanks

 

ILO4 FW 2.55 - "The Self-signed SSL certificate can now be regenerated"

$
0
0

Noticed this addition to the 2.55 ILO4 firmware release, thought I would give it a go in a few of our test labs where we don't bother with CA issued certs, but I don't see any new buttons or features in the ILO Web Inerface to initiate this "regeneration".  I checked in the RBSU and didn't see anything there, nor in the F8 menu at boot time.  I haven't ssh'd in to check there yet.  Just figured I would ask here:  Anyone figured out how this gets done?  Link to relevant release here:

https://support.hpe.com/hpsc/swd/public/detail?sp4ts.oid=1009143853&swItemId=MTX_6325ea9b58fd4191abac45a154&swEnvOid=4184#tab2

 

App to update drivers/firmware to latest versions?

$
0
0

I am looking for something like HP SoftPaq Download Manager....but for servers. 

I have used SPP 2017.10 to update my servers, and that works great. I'm sure there is just newer versions and wanted to do that as part of my Windows update cycles. 

I have a mix of DL360 G7, DL380p G8, and DL380 G9. Centralized would be great, but I am okay with something I run on each machine. 

I typically work with Dell, and they have Open Manage Essentials for centralized and Dell Command Update for single runs. Have not quite found the HP/HPE equivalent. I installed HP System Insight Manager, and see the option for Software/Firmware Baselines, but not sure how to tell it to look wherever for new software. 

Thanks for any input. . 

 

HP Proliant ML110 G7 UID lit Automatically, not able to get out of the UID Mode.

$
0
0

HI guys,

I have HP Proliant ML110 G7 Server with Windows Server 2008 R2 SP1 Installed. Yesterday i've installed Genetec (Video Management System) for our needs, just after the installation completes the server went to UID mode.

I can't able to come out of the UID mode even i tried unplugging the power chord and replug. 

Please help me to solve the issue....

Thanks in Advance....!

drive array controller failure (slot 0)

$
0
0

Several days ago, I replaced the internal battery of the BBWC for the Smart Array P410i controller since I was getting messages in the log of the insight agent that the previous battery was depleted.

Error Code:  capacitor-based cache module capacitor failed to charge 

After the replacement, the server (HP DL360 G7) booted, and still works, just fine but ever since although the HP System Management reports that the overall system health is OK, every 14-20 hours I get in the Intergraded management log the following msg

drive array controller failure (slot 0)

I' m guessing that the problem is with the BBWC module but did any of you seen anything like this before? Can I just ignore the message since the system health is OK? Any suggestions?