Quantcast
Channel: ProLiant Servers (ML,DL,SL) topics
Viewing all 10362 articles
Browse latest View live

Proliant 380gen9 & P440ar & Mixing 12g SAS & 6G sas

$
0
0

This seems like a basic question but I have to ask...

 

With the DL380 gen 9 and P4540 controller, can I mix 6gb SAS and 12GB sas in the same RAID 6 array?  I assume the 12GB sas drive would know to slow down but I have read some places that some controllers may have issues with this and won't slow down the faster drives to accomodate this.  Is there any official documentation from HP that would state this?  I’m looking to expand my storage on my g9 and it currently ahs 1.2TB 6g SAS drives -  718292-001 with 12GB sas drives - 872479-B21.


Server wont start

$
0
0

Hi

I have a situation that my server HP ProLiant ML350 G4p does not start correctly, when i push the power botton the chassi fan start running at full speed and doesnt stop, no image its shown, no beeps, no red leds. actualy all the leds seems to be ok. 

the only thing i did to try resolve the issue was cleaning the dust and cleaning and removing the RAM.

any advise?

thank you

HP DL380 G9 Power Supply 3

$
0
0

Hey,

we use a DL380 G9 as ESXi Host. Now my VM vSphere Client tells me, that my Power Supply3 Redundancy lost.

I attached an Image, so maybe somebody can imagine something. The DL380 G9 only have two Power Supplies.

Can someboy Help me please? :)

Greetings from Germany!

SYSTEM HALTED

$
0
0

I HAVE A HP PROLIANT DL580 G7 SERVER FACING SYSTEM HALTED PROBLEM.

Proliant DL360p gen8, Unable to Boot when hbamode=on

$
0
0

Hi,

I'm tring to setup a ceph cluster for openstack on Prolaint dl360p Gen8.

In order to show all disk to the OS, I put the controller p420i on HBA mode.

# ssacli controller slot=0 modify hbamode=on

The OS was installed succesfully, but the server was unable to boot!!.

Is there any extra steps to make the server boot?

Thanks in advance.

Best regards,

HP ProLiant ML350 G6 O.S. Support

$
0
0

Hi al,

I have a server HP ProLiant ML350 G6  Serial Number CZJ14805RV Product NO. 470065-570.

I have two questions: 

a) Is possible to install Microsoft Windows Server 2016 Standard ?

b) Is possible to installa VMWare ESXi 6.0 or 6.5 version?

This server has install a ESXi 5.5.0 build 3248547 with Windows Server 2003.

Thanking in advance.

 

Giuliano

HDD HUC109060CSS600

$
0
0

Hello,

I was buy 4 SAS HDD HUC109060CSS600 2.5".
I use this on our DL380 G7 servers.

Problem is, that the server RIAD controller dont know this HDD. 
Can somebody help me, what of problem is ?
I have also same HDD, only 15000 RPM - model HUC156060CSS200  - this work fimr

Regards
Jaro Jasek

ProLiant BL460c Gen8 firmware

$
0
0

I've been having issues upgrading vmware from 5.5 to 6.5 so Vmware support have asked for some firmware to be upgrade.

Their email said:

As per the log bundle:

ESXi 5.5.0 build-3568722
   
HP ProLiant BL460c Gen8 | BIOS: I31 | Date: 05/21/2018
        
        Intel(R) Xeon(R) CPU E5-2670 0 @ 2.60GHz

                NIC     driver name  VID:DID    SVID:SDID  driver version  firmware version
                ------  -----------  ---------  ---------  --------------  ----------------
                vmnic0  elxnet       19a2:0710  103c:337b  11.1.145.0     11.1.183.23
                vmnic1  elxnet       19a2:0710  103c:337b  11.1.145.0      11.1.183.23
                vmnic2  elxnet       19a2:0710  103c:184e  11.1.145.0      11.1.183.23
                vmnic3  elxnet       19a2:0710  103c:184e  11.1.145.0      11.1.183.23
             
                  vmhba0    Hewlett-Packard Company Smart Array P220i
        vmhba1    Emulex Corporation Emulex OneConnect OCe11100 10GbE, iSCSI UCNA
        vmhba2    Emulex Corporation Emulex OneConnect OCe11100 10GbE, iSCSI UCNA
                -----------------------------------------------------------------------------------------------------------------
                HBA     driver name  VID:DID    SVID:SDID  driver version
                ------  -----------  ---------  ---------  --------------
                vmhba0  hpsa         103c:323b  103c:3355  5.5.0.124-1OEM
                vmhba1  be2iscsi     19a2:0712  103c:337b  11.1.145.8
                vmhba2  be2iscsi     19a2:0712  103c:337b  11.1.145.8
            
As per VMware Compatibility Guide,the latest recommended version is as follows:
                
hpsa driver version 6.0.0.44-4vmw

Link for Download:

http://www.vmware.com/download/vsphere/drivers_tools.html
                    
                    
be2iscsi driver version 11.1.145.8 firmware version:    11.1.145.18

Link for Download:

https://my.vmware.com/web/vmware/details?downloadGroup=DT-ESXI55-EMULEX-BE2ISCSI-1111458&productId=353
                        
                        
elxnet driver version 11.1.183.654    firmware 11.1.183.23

Link for Download:

https://my.vmware.com/web/vmware/details?downloadGroup=DT-ESXI55-EMULEX-ELXNET-111183654&productId=353

they posted links for drivers but i can't find the firmware 11.1.183.23 for elxnet or 11.1.145.18 for be2iscsi on hp's site: https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=5177951

 


ProLiant-DL360-Gen8 MIB file location?

$
0
0

Hi,

Does anyone have the locaction where I can download the MIB file for my server? In the documentation is a old link. This link is dead. On the internet I keep finding the same link and not the MIB file. 

 

https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_64712646e88c431fb5e82e37cb << This link give me the MIB kit. But there are so many MIB's in it, that I am not sure if this MIB file got they right MIB for me. And testing them all, will take me to long. 

P.S.

HP please stop placing all MIB files together in one file. I toke me days to get the right MIB for my switch and now I am stuck with my server.

ML110 G7 Centos 7 possible?

$
0
0

I've got a new in box ML110 G7 that I'm going to set up for home use and I'm considering Centos 7. Centos 6 has drivers on the HPE website for the storage array (RHEL 6 driver disk) but I'm wondering if the 2020 end of life of Centos 6 will be an issue since it will be internet facing for a Owndrive instance.

Anyone have any experience setting this up with HPE drivers for the array versus just flat disks? I'd appreciate any experience you all have.

 

DL380 G10 with the 6+2 NVMe Cage

$
0
0

Hi,

A customer has a DL380 G10 8SFF with Dual 10 core procs, 64Gb, iLo Advanced, Dual PSU, the Premium 6+2 NVMe cage in bay 3, the 1 port 2NVMe SlimSAS Riser in the primary location. For some reason they cannot view the NVMe 2.5inch ssd's. Cabling as per the user guide, pic attached. 

How does one enable NVMe? This hidden in the Systems Configuration?    

Regards,

Storage Physical Disk failure alarm

$
0
0

Dear experts ,

HP DL360 Gen9

smart array P441 controller

Enclosure D3700

During testing Physical disk removal alarm (SNMP Trap) from the D3700 enclosure, in the NMS system they are receiving two alarms, one is related to the logical drive faulty, another related to the spare disk which took place as a backup for the faulty one. We should receive a 3rd trap notifying about the phsysical disk failure. Unfortunately this is not recieved in the NMS monitor.

Disk details with Firmware version is attached for reference,

Can you help me here?

thanks in advance,

 

 

Storage power supply number alarm is not visible in NMS

$
0
0

Dear Gurus,

server details : HP DL360 Gen9

Controller  details :  smart array P441  Controller

Enclosure Details : D3700

We are facing a strange problem here!!! we are running some testing on snmp alarms sending towards NMS server. when we remove the storage power supply, alarm is been sent toward NMS system. however, it not showing which power supply is the faulty one. below is the message visible in monitoring system : 

IP:xxxxxxxx,NodeName:xxxxxxxxxxxxx,One of the Storage system power supply status changed to degraded for ControlIndex: 1. HwLocation: Slot 1, BusIndex: 2, SerialNumber: xxxxxxxxxxxxx, Location: Port 1E Box 1

Whereas in the IML logs we can see the alarm properly : "External storage  Enclosure  Power supply failure (power supply2, Box1, Port 1E, Slot2)

Our customer are reluctant to accept this as it seems crucial to them

Can anyone help here??

thanks,

 

Creating a logical array with iLORest - correct syntax?

$
0
0

I am running the ilorest.exe tool from WinPEv10 on some test 380 Gen9 and 10 servers.

Looking through all the documentation doesn't give me the correct syntax for creating a logical drive.

I am running this command from powershell:

ilorest.exe --nologo --nocache createlogicaldrive customdrive RAID1 "1I:3":"1,1I:3:2" --name=LogicalDrive0 --spare-drives="1I:3:3" --spare-type=Dedicated--capacityGiB=-1 --accelerator-type=ControllerCache --controller="Slot 0"

It tells me "One or more properties were changed and will not take effect until system is restarted"

So it all looks fine.

When I run ilorest.exe pending it shows the logical drive pending creation but the "Sparedrives=" and "Datadrives=" sections are both blank, no drive identifiers are listed.

Does anyone know how to tell this command which drives to use?

I have tried the drive identifiers above (1I:3:1, etc) and [1] and 1 but none seem to work.

HP ProLiant ML310e Gen8 v2 and HP 361T Adapter

$
0
0

Hello.
purchased an HP 361T Adapter, inserted in the PCI-E slot 2, the card in the device inventory is displayed, the product number, serial number is visible, but the status is "unknown".

sinned on the BIOS, updated and put the latest version, does not help. does anyone have an understanding of why so?


DL360e with P222 can not change the cacheratio in VMWARE CLI

$
0
0

I have tree DL360e Server with a P222 Smart Array Controller unter VMWARE ESXi 5.5
VMWARE was installed with the HPE Image.

Now i want to change the cacheratio on the controller.

First i read the settings

Smart Array P222 in Slot 1
   Bus Interface: PCI
   Slot: 1
   Serial Number: PDSXH0BRH6J164
   Cache Serial Number: PBKUD0BRH3U14R
   RAID 6 (ADG) Status: Enabled
   Controller Status: OK
   Hardware Revision: B
   Firmware Version: 8.00
   Rebuild Priority: High
   Expand Priority: Medium
   Surface Scan Delay: 3 secs
   Surface Scan Mode: Idle
   Parallel Surface Scan Supported: No
   Queue Depth: Automatic
   Monitor and Performance Delay: 60  min
   Elevator Sort: Enabled
   Degraded Performance Optimization: Disabled
   Inconsistency Repair Policy: Disabled
   Wait for Cache Room: Disabled
   Surface Analysis Inconsistency Notification: Disabled
   Post Prompt Timeout: 15 secs
   Cache Board Present: True
   Cache Status: OK
   Cache Ratio: 100% Read / 0% Write
   Drive Write Cache: Disabled
   Total Cache Size: 2.0 GB
   Total Cache Memory Available: 1.8 GB
   No-Battery Write Cache: Disabled
   SSD Caching RAID5 WriteBack Enabled: False
   SSD Caching Version: 1
   Battery/Capacitor Count: 0
   SATA NCQ Supported: True
   Spare Activation Mode: Activate on physical drive failure (default)
   Controller Temperature (C): 88
   Cache Module Temperature (C): 36
   Capacitor Temperature  (C): 0
   Number of Ports: 2 (1 Internal / 1 External )
   Driver Name: HP HPSA
   Driver Version: 5.5.0
   PCI Address (Domain:Bus:Device.Function): 0000:08:00.0
   Host Serial Number: MXQ41703W6

Now i try the command

/opt/hp/hpssacli/bin/hpssacli ctrl slot=1 modify cacheratio=25/75

and i recieve the message

Error: "cacheratio=25/75" is not a valid option for Smart Array P222 in Slot 1   There are no options currently available.

on the outher 2 servers the command runs without problems.

 

 

HP DL380 Gen10 Network Setup

$
0
0

Hi,
This may sound amature  , I have purchased two DL380 Gen 10 servers, but wanted to understand on ways i can integrate the server to my switches 

I have attached a very simple diagram, i want to utilise the 10GB network cards and wondering if the attached setup would work.  

HP Diagram Option 1 is my preferred setup 


GP Diagram 2 is Option 2 but not my first choice. 
Cisco Switch > Connect 4 DAC cables from the server to single Switch 

 

 

DL380 Gen9 SERVER - DRIVER POWER STATE FAILURE

$
0
0

Hello , 

We have the following Problem on an HP DL380 Gen9 Server . 

Operatingsystem is W2016 Server 64bit . 

Inserted are 2 x H221 , 2x H241 Cards on which is an Netapp E-Series Storage and 4 x LTO7 Tape Drives in an MSL 4048 connected. 

2x H221 - Netapp Storage 

2x H241 - LTO 7 Tape Drives . 

All Engery Save Settings are turned to off . The Server is set in BIOS to maximum Performance Mode. 

All Drivers and Firmware are Up to Date . Service Pack iso 06-2018 is allready installed . 

When we restart the Server then first the "Rebooting" from W2016 Server is shown for 10 minutes , after this the Bluescreen appears with : DRIVER POWER STATE FAILURE 

In the ILO Management Log there are this entrys :          

PCI Bus 07/19/2018 07:41   Uncorrectable PCI Express Error (Embedded device, Bus 0, Device 28, Function 4, Error status 0x00000000)         

PCI Bus 07/19/2018 07:41    Uncorrectable PCI Express Error (Embedded device, Bus 0, Device 0, Function 0, Error status 0x00000000)

System Error      07/19/2018 07:41  Unrecoverable System Error (NMI) has occurred.  System Firmware will log additional details in a separate IML entry if possible

PCI Bus 07/19/2018 07:41      PCI Bus Error (Slot 0, Bus 0, Device 0, Function 0)

The Mainboard is changed from the HP Technical Support for the second time. 

Hope someone can help me . 

Thanks 

Michael 

 

Drive keeps on being unassigned after reboot - B120i Raid Controller (DL320e G8)

$
0
0

Hello,

I've disconnected my disc drive, and instead have opted in to install a SSD instead. The SSD is recognised by the system, under the B120i Embedded Raid Controller. I create a logical drive of RAID 0, rescan the system to see if it's completed, and it's all good! After I reboot the system, the system states that no logical drives have been installed on that raid controller. I open up the raid utility, and it shows that no logical drives have been created! What's the issue?

I also have a B220i raid card installed in the system as well, which works perfectly fine with 4 x 3TB drives installed, all under RAID 0, which is not affected by the above.

Thank You!

HP DL380 G8 Nvidia GRID not showing up

$
0
0

Hello,

i am currently trying to deploy 3x Nvidia GRID K1 and 1x Nvidia GRID K2 in 4 of my DL380 G8 Servers.
For the deployment i ordered the following parts besides already owning the Servers with Dual V2 CPUs and 1200W PSUs:

3x 710727-001 ( Secondary Double Wide GPU Riser Cage)

3x 670728-001 ( GPU Y-Power Cable ) 10pin -> 8pin + 6pin

I have put 2x K1 and 1x K2 in the riser and attached the cable. After Installing the riser into the server i started it and the Riser card LED showed up as green as well. In neither BIOS or Standard Debian Live the cards are showing up. I tried all 3 riser.. No Luck.

For the sake of comfirming that the cards are fine i tried them in my workstation and they showed up from second 1 in my Device Manager on Windows. For eliminating the Riser having issues, i installed an H241 HBA into it and it got recognized as well without issues.

I would really appreciate any help to get those cards working in my Servers.

 

Viewing all 10362 articles