Добрый день.

У нас в наличии есть 2 сервера proliant dl380 gen9, из пяти SAS HDD сделан RAID 5.

Есть ли у вас бесплатное программное обеспечение для отслеживании работоспособности жестких дисков?

Google Translated

RAID software
Good day.

We have 2 proliant dl380 gen9 servers, out of five SAS HDD made RAID 5.

Do you have free software to track hard drive performance?

HPE ProLiant DL20 Gen9 - Memory upgrade

$
0
0

Hey Guys!

I hope you are doing great.

I'm writing this thread, because I'm getting confused with so many documents related to this simple task. Recently I've purchaised HPE ProLiant DL20 Gen9 product code 830702-425. iLO presents that in my server I've following memory (797258-081) inserted. Now on this HPE page here they says it's assembly part number for HPE 8GB (1 x 8GB) Dual Rank x8 DDR4-2133 CAS-15-15-15 Unbuffered Standard Memory Kit and from what I understand I should search for 805669-B21 or 819800-001 memory part numbers, am I correct? Would that be compatibile?

Thank you very much for clearing this doubt.

Best regards,

Adrian

Drive in RAID 1 array "is predicted to fail soon". Replaced with new drive and no change.

$
0
0

Hi, 

I have a DL360P Gen 8 with a P420i SmartArray. 

I have a RAID 1 array that showed a drive "is predicited to fail soon". I replaced the drive with a new drive with the same HP part number. New drive started to show as rebuilding. Rebuild never finished. New drive went into "is predicted to fail soon" status (warning 341) status. 

Can anyone recommend troubleshooting steps? At this point I'm not sure if the new drive is also bad or if there could be something else such as loose cable somehwere. 

Sidenote: I also started receiving message 263: SMART Array P420i in Embedded Slot has one or more cache module batteries/capacitors that are failed. Caching operations such as Expansion, Extension, and MIgration are temporarily suspended until the batteries/capacitors are replaced. Please consult the user guide to identifiy and repalce the failed components.  Are these two problems related?

 

Moving an array from a DL360G9 to another DL360 G9

$
0
0

I plan to save some setup time on my O.S , applications and database. I have an array of RAID 1 which I plan to unplug it from DL360G9and let call  it A server.  I plan to re-plug in these 2  HDD RAID 1 into  another  DL360G9 call it  B server on the same RAID 1 configuration and HDD slot on the B server. Will it work fine for the B server?

HDD Failure or maybe not

$
0
0

Hey guys,

i was going through the inventory of a customer of us and this confused me a bit.

Server is a ProLiant ML330 G6 with a P410 controller.

The Log Viewer claims that there is a failed drive, but the Array config and the LED indicators look fine.

IM Log Viewer

Array Configuration Utility

LEDs up front

I would say safety first and replace the drives, what do you recommend?

Thank you

Connecting to remote console on a DL380 G5 from macOS

$
0
0

I got hold of a decomissioned DL380 G5 which I'm setting up as a home lab and have some issues figuring out how to take advantage of the remote console offered by ILO 2.

Using a Mac my options seem limited to using the Remote Console Java Applet - which is a problem when all browser except IE have recently dropped support for Java Applets.

Does anyone have a solution to accessing the remote console on this server, from a Mac?

Thanks

/Geir

Moving RAID drives from G1610T to DL360e

$
0
0

I've been running a Gen 8 Microserver for a couple of years now, ESXi and a couple of VMs just for basic home office use. I've come to a point where the slow performance of the machine is starting to become a problem and so I've managed to source a faster Gen 8 DL360e to replace it.

I currently have 4 x 3TB drives set up in RAID 10 and I was wondering whether it'll be possible to simply move those drives into the DL360e? To the best of my knowledge both machines have the B120i onboard RAID controller - so I was thinking it should 'just work'. Can anyone confirm?

I was also wondering if I'd be better served getting another couple of 6TB drives and putting them in the new machine at RAID 1, with a view to adding another pair of 6TB drives at a later point. So I was wondering if it's possible to add drives to an existing RAID 1 array to convert to a RAID 10.

Thanks

 

ML350 G6 firmware update DVD

$
0
0

Hi,

I inherited an HP ML350 G6 and was wondering how to update the firmware ( BIOS, disks etc) ?

I understand that HP does not give away any software anymore.  Is there somewhere i still can download the firmware DVD for this machine ?

The machine is ( i guess) 10 years old, and i have no contract with HP.........

Please help .......


changing UEFI to Legacy BIOS and vice versa after server O.S installed.

$
0
0

Hi ,

   I'm have some  DL360G9 servers and installed with W2k12 , W2008k & LInux Redhat O.S. The server was configured to boot on UEFI during the installation of these O.S. Is there any  boot issue if I change it to legacy boot at later stage?

I'm running on RAID 5 and RAID 1+1.

Thanks.

 

ihave return cod:7 when installing firmware update 562flb

$
0
0

ihave return code:7 when installing firmware update 562flb with spp 03.2018. how can fix it?

create partition harddisk

$
0
0

Dear All,

i had server HP PROLIANT ML 350 Gen 9 and operation windows 2012 R server, and i buy a new harddisk 1,2 tb sas 2,5 in, please explain to me, how to create a new partition. sorry my english really bad

regards

Tony

 

 

Dynamic Smart Array B120i RAID cache module batteries/capacitors that are recharging

$
0
0

I have a HP Proliant DL360e G8 with the Dynamic Smart Array B120i RAID embedded controller.
the 512MB FBWC module with capacitor pack are installed.
For some reason I get two warnings an the cache is permanently disabled :

772 Dynamic Smart Array B120i RAID in Embedded Slot has one or more cache module batteries/capacitors that are recharging. Caching operations such as Expansion, Extension, and Migration are temporarily suspended until the batteries/capacitors are fully charged. Caching operations will automatically resume when charging is complete.

825 The cache for Dynamic Smart Array B120i RAID in Embedded Slot has been disabled because the cache module encountered a hardware failure.

It must be a firmware problem. I tried installing the most recent firmware cp027853.exe and ran the ADU diagnostics. The status remains charging and the cache is permanently disabled. Can you please help me fix this problem?

NO Option to Select RAID 5 in HP DL 380 Gen 7 Servers

$
0
0

I have been configuring HP DL 380 Gen 7 Server. It has 8 900 GB HDDs and i need to configure it in RAID 5. When i start configuring RAID with SmartStart it is not showing RAID 5. It only shows RAID 0 and RAID 1.+0. I have changed the strip size and sectors/Track etc.. But it doesnt works. It has smartarray P410i.

I have already configured another HP DL 380 Gen 7 server without any issue. It shows RAID 5 in it and i configured it in RAID 5. Both server has smartarray P410i, one shows RAID 5 and other not.

Please Help.

Install Ubuntu server in HP Proliant G20 Gen9 use Smart Array B140i

$
0
0

Hello !!

 Tell me please, how install Ubuntu server OS and configure RAID 1  use internal Smart Array B140i in this server?

I`m try, but when install system installer not see logical volum which I configured in the internal utility , see two hard drive.

When trying to add a new baseline to HP smart update manager 8.3.5 inventory in process never finish

$
0
0

I have been trying to complete a baseline inventory for 3 days now, all it says is inventory in progress, processing 1085 out of 1085 components.  But it never finishes.  Anyone ever see this?  I was able to ad a baseline for the G9, but this G7 is taking forever...I also have had this issues with other s before, wondering what makes this happen.Capture.JPG


Change fan to another fan connector

$
0
0

Hi , all.

Our server Proliant ML350e Gen8 v2,  had problem with noisy fan. We use 2 Fan. Tried with upgrade ILO firmware, but not successfull. Fan1 that connected to fan connector 1 is really noisy , tried to move to fan1 to fan connector 3 and fan1 operate normally. But cause error 1611 - CPU Fan Failure when booting, but I'm sure that fan operated normally , it spin. 
My question why I can't move fan1 to connected to fan connector 3, and cause the server shutdown.

HP ProLiant ML10 Gen9 Won’t Update

$
0
0
Hi,

I’ve been battling with this server for months with HPE changing the MOBO yet I still have the same issues. I’ve tried other hard drives to try eliminate hardware but can’t get past the following updates.

KB2267602
KB4462928

I’m just going round in a continues cycle trying to update then they fail. On other occasions before this most recent install, it would not show any users in the dashboard and stopped sending health reports. They are ok at the minute but expect that to change like before.

The software is HPE ROK Windows Server Essentials 2016. Could it be the software?

Hope you can help.

Cheers, Mick

ILO 4 - overview and system information missing

$
0
0

Hello,

 

We have HPDL380p Gen8 server. Recently we reset ILO as we were unable to login to ILO.  Whilst the login issue has resolve, we are having issue with ILO information displayed in overview and system information.

The  UUID , server serial number, system ROM etc are showing as UNKNOWN and most of the components under system information is showing as NOt available.

Do we really need BIOS upgrade and/or NAND format to resovle this issue?

Will rebooting the server will resolve this issue - as in can we get all the information back by rebooting?

If  there is any other way, please advise.

 

Many thanks.

 

Firmware update using HP Openview

$
0
0

Hi Team,

Can you please point me the steps to upgrade firmware using HPE Openview.

Thanks in advance,

Thiyagu

how long does it take to install this version 7.2

$
0
0

Hi,

Does anyone know how long does it take for this Linux version7.2 take to install? Mostly looking for the manual labor associated with the screen shots that will guide me to install it?

Viewing all 10362 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>