HP Proliant DL380 GEN9 2nd Raid Card

$
0
0

We are having raid performance issues on our HP Proliant DL380 Gen9 server with the P440ar raid card PN 726736-B21. So i would like to install a 2nd raid card to move one of our SQL servers onto a new raid built with SSDs. I'm looking at ordering the HP P440/4GB FBWC 1 port SAS controller PN 726821-B21 with 6 of the HP 400gb 12G SAS Mainstream Endurance drives PN 741142-B21

From what I've read both of these should work with 2 raid cards in the GEN9 server. The problem I'm having is I think I need to order some type of tray that the 2.5" drives actually sit in and that connect the drives to the server.  So basically two questions?

Do I need to order cables or will the new card come with that? 

Do I need to order a hard drive backplan kit? It looks like this could be the correct part? 719067-B21 or 768856-B21..

Am I missing anything else required to get this setup? 

Thanks


Enabled FIPS on ILO5, Now can't login

$
0
0

I enabled FIPS on the ILO on my Gen 10 DL380 and now the logins I had previously setup in the ILO don't work so now I can't login to the ILO and can't disable FIPS again. Is there some way to set this back so I can get back into the ILO? I didn't realize that settings FIPS would lock me out of the ILO. Thanks.

wwpn information

$
0
0

Is it possible to find wwpn/wwnn information for a bare metal server using powershell or REST. I looked at the HP ILO cmdlets and I do not see anything I can use to pull up the information. I could go into the ILO but trying to automate.

 

thanks

dl 380 gen 10 showing error message while booting the windows 2016

$
0
0

x:\windows\system32>hpev CQTESS
Error: deleting EV CQTESS


X:\windows\system32>exit /b 0

X:\windows\system32>

it will halt and cannot boot the 2016 server. help me

trouble booting ubuntu server 18.04 LTS after installation on HPE proliant ML30 gen9

$
0
0

SO! I just bought my first HPE proliant ML30 gen 9.

I just got it.... unboxed it.... unpacked my 2 new harddrives... put them inside the server...  pluged in the cables.

I then put in my usb bootable drive med ubuntu server 18.04 LTS.

I went through the installation....... it had to restart (and the guide on ubuntus site told me to pull out the usb, before restarting)...

Now... it just reboots, and tell me there is nothing bootable?.......

Everything is brand new, and this is clean installation... I can't figure out what I have done wrong?

Please help me, before I have pulled out the last hair on my head.

Does Proliant ML10 supports SSD

Smart Array P440ar warning message

$
0
0

Any thoughts?

The cache for smart array P440ar in Embedded Slot has been disabled because the restore operation failed.

Thanks

Windows server 2019 on HP ProLiant DL360 Gen10

$
0
0

Hi,

We just got DL360 Gen10 and when I'm about to install Windows 2019 from an ISO image stored in USB using Intelligent Provisioning, after selecting the ISO file the page just refreshed and the next button won't come out. this problem didn't happen if I used lower Windows Server version like 2012.


ProLiant ML350p Gen8 : POST Error: 1803-Slot X Drive Array - Cache Module is not installed

$
0
0

Hello,

We have purchased a ML350p G8 and now we are in need of more diskspace, to do so we ordered a second cage and a P420 controller. However after installation of the hardware we keep getting the error that the cache module is not installed. We tried with other hardware (module) but it still gives the error. What are we missing? The controller is recognized, but the cache module not.

The system hosts an ESXI 6.5 instance with 4 Virtual Machines

Poor disk performance on DL380G9 with Smart Array P440ar

$
0
0

Hi,

My Proliant DL380 G9 reflects very poor performance when performing winsat test. I hardly get a 6MB/s random read! I have 3 300GB disks attached to a Smart Array P440ar controller, configured as 2 logical drives: one simple volume (attached to 1 disk) and a stripped volume on 2 disks. No encryption and cache module installed.

Does anyone have an advice to improve performance?

ML10 v2 CPU Current Throttling

$
0
0

I have current throttling when running i7-4790k on default, stock settings. Is there a way to know what the current limit is or adjust BIOS to avoid throttling, assuming it is safe? I'm using Intel Extreme Tuning Utility to monitor the CPU's condition.

What is default IP of ILO Port

$
0
0

Hi everyone,

I just want to configure IP address on iLO port on my server HP 580 G9 without restart server.

So I would like to know what is default IP address of HP server. 

 

Currently it is running VMware ESXi, so I don't want to interrupt operation. Or any solution to configure IP address on ILO port thru ESXi?

Could you anyone help on this ?

 

Thanks so much for your great help.

 

Best regards,

 

Kimsin

 

new HDD in old server

$
0
0
Hello everybody
We have a DL 380p gen 8.
We are going to add some new SAS Drive . Accurindg to information within Quickspec we found some new sas drives which are added to last version of QS (since Sep 2015). Can we order this drives and install them into our server? Or they belong to new version of server?
I mean, is server’s production time important?

ProLiant ML110 G7 UEFI?

$
0
0

Hello and good evening,

I'm looking for informations about bio type of  ProLiant ML110 G7 server.

Is it already EFI/UEFI?

Unfortunately I couldn't find any about this topic  in www.

Regards

Walter

Advice on System Power Fault Detected log message

$
0
0

I'm running several ProLiant DL360p Gen8 servers with Centos 6.6 for scientific high-performance computing. All servers where bought in 2012. Now it happens more often that some servers shut down unexpectedly with fast-flashing Health LED on front panel, indicating a Power-fault.

However both power supplies seem to work after reboot. I've installed hp-ams to be able to read BIOS log data. The most recent message is: 

0019 Critical       09:14  07/04/2018 09:14  07/04/2018 0001
LOG: System Power Fault Detected (XR: 10 00 MID: FF 0D FC 06 FF FF 2A 2A 0C 0C 40 3F 04 00 03 01 81 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00)

Q1: Any advice on this error code?

Q2: Where can I get information on the meaning of these error codes?

Q3: Any suggestions on what to do?

Thanks,

KK

 


Hp Ml350P G8 Adding More drives

$
0
0

I have a Hp Ml350P g8 Server, currently it has the 6 x 3.5 LFF drive's in it, and using the Onboard 420i raid card, i have been googling ALOT for the last few days on how to expand the storage capabilities, this is leading me to buy part number 693611-001 witch is a backplane-expander.  No where on this earth am i able to find one, yet it's an option to buy from HP.  Anyone have any links to get one ? I just want to add more drives..

 

Pic attached is what i need. to make this work

 

Thanks in advanced. back-Plane

Blinking Red Internal Health Light on Proliant ML350 G5

$
0
0

Hello,

I've come across a particular problem on our old (but very usefull) server . The internal health light is blinking red and the external health was orange. I put the power cable on the 2nd psu and the external health led is now green but the interal health led in still red. I removed the HDDs, the RAMs and the battery. I reinserted the battery and 1 ram and booted up. Still the same. On the motherboard the only amber led is the PMM2 but there is no PMM2 installed on the server. The server only has 1 cpu. I tried to switch to slot 2 to see if that works but still nothing. Does anyone have any idea of a possible cause? I have provided an image to the motherboard:
http://tinypic.com/r/302tbfk/9

Thank you in advance.

Install HP server SSA

$
0
0

안녕하세요 서버초보자 입니다.

 

HP서버를 설치하고 SPP를 깔고 나서 SSA를 사용하려고하는데

 

SSA를 실행시키면 아래와 같이 오류만 뜹니다.

 

원인이 무엇이며, 어떻게 해결해야 하나요

 

Google Translated

Hello server is a beginner.

After installing the HP server and installing SPP, I try to use SSA, but when I run SSA, I get an error like below.

What is the cause and how do I solve it?

---------------------------------------------------------------------------------------------------------------------

The smart storage administrator (SSA) cannot execute in this browser environment.

Possible reasons include

- this browser is not supported

- the current settings of the browser are preventing scripts from being run. javaScriptmust be enabled for the application to run

Please check the SSA documentation for supported browsers and required browser settings.

---------------------------------------------------------------------------------------------------------------------

Unable to connect error when booting SPP from PXE

$
0
0

Hello everyone,

I have this issue with SPP when booting it from PXE server. Its Windows WDS pxe server, which runs linux boot files (pxelinux.0 if im correct). DHCP and all that stuff works properly. Kernel, initrd files and arguments are set up according to the SPP release notes PDF (page 15).

When selecting SPP from PXE boot menu everything works great, client gets the IP, connects or pulls the ISO image from the IIS share. HPE logo pops up and then it fails with Unable to connect browser screen (see attachments). What could cause the issue (could it be the image itself?).

Had no issues with other OSes.

Microserver (N54L) not booting?

$
0
0

Hi all,

I've bought a G7 N54L second hand - it has 3 drives but had no RAM so I bought a single 4GB RAM and have installed that (while unpowered).  On power-on, the fans spin, the power LED is green, the HP logo is red, and there's no display (no signal detected) on the attached monitor.

Have I bought a pup, or is there more troubleshooting I can do?

Cheers!

Pippa