GPU on ProLiant ML310e Gen8 or DL320e Gen8

$
0
0

Hi all,

 

I have two kind of servers, ProLiant ML310e Gen8 and DL320e Gen8, and I would like to add GPU on them. I was thinking on adding Nvidia GTX 2080ti.

Do you think it is possible? I tried to do some searches, and I mainly fund people having issues installing them. Are there some specific issue to consider while choosing/installing GPUs?

 

Thank you for your help

 

Regards


Installed RAM memory and usable

$
0
0

Hello,

I recently upgraded the RAM at my HP Proliant ML150 GEN 9 server, added another 32 GB.
Windows Server has recognized the installed quantity but does not allow it to be used, displaying:

Installed memory (RAM): 64.0 GB (usable: 31.7 GB)

I use Windows Server 2012 R2 Standard.

Please, anybody know how i fixes it ?

Run proactiveHA via Oneview in vcenter

$
0
0

Dear all

Hi

 

i want to run proactive HA

my server is DL580 G10

i have download and deploy HPE_OneView_for_VMware_vCenter OVA file and add vcenter to that.

also i have installed HPE_OneView_4.20.01.01_ESXi_Z7550-96659.ova

my vcenter ip = 10.10.50.60

my  one view ip = 10.10.50.77

my HPE_OneView_for_VMware_vCenter  = 10.10.50.78

now from Menu- Administrator - HPE one view for vmware vcenter - server integrations:

in this part we can see to tabs : Oneview - servers

 

in the server tab i added my esxi host (this is lab and i have just one esxi host )

in the one view tab i insert hpe one view ip and creditional  (10.10.50.77)

 

but during registering show : Error while registering Hypervisor Manager or Oneview

 

how can solve the problem ?

How to backup a failing raid controller

$
0
0

Hi,

We have a DL-380 GEN9 server which has a tempormental raid controller (stops working when the server is under alot of load).

We are wondering if there is a process to take a backup of the raid controller / restore onto a replacement raid controller?

Thanks for any replies that do come in!

 

Run proactiveHA via Oneview in vcenter

Remote power on

$
0
0
Hi I own a D380 7gen server and I was wondering
Is there and way not using ilo I could power up my sever without even being home

Such as if my server needed to boot but I wasn’t home how else could I boot it.

DL380 Gen10 M.2 enable

$
0
0

I have installed an NVMe M.2 drive into drive 13 on the riser card.  I was not finding the device, nor any area in the BIOS that finds the devices for boot.  I could not find anywhere to enable the function.  Are these devices available for boot?  

Change Harddisk for HP Proliant ML350 G6 Server

$
0
0

Hi, i need some help or advise from all the experts.

I have a HP Proliant ML350 G6 Server with 300GB x 6 harddisk slots in Raid 5,  due to not enough harddisk space, i would like to replace 300GB x 6 harddisk to 3TB x 6 harddisk in Raid 5, i would appreciate if anyone can tell me how to do it, thanks a lot.


ML570 Server

$
0
0

Hello. My name is Rick.

I recently recieved a server from a friend of mine.

This is a Compaq Proliant ML570. It has 4 scsi 10000 rpm 18.x gig drives. It has one ide cdrom and one 12/24 gb tape drive. It also has a one floppy drive. I have added a scsi cdrom drive. edit: oops. It is a G1 machine. 2/4 Pentium iii Xeon and 1 GB of ram.

I can get it to install RedHat 8.0 but it will not boot.

I believe the two sets of two scsi drives are not seen during boot because a driver is not loaded so they can be seen.

I guess I need a boot drive.

What kind of configuration did this machine have and where can I get SmartStart 5.5?

Thanks.

Server after downgrade firmware doesn't work

$
0
0

Hi. 

I have HP ProLiant DL 580 G7.

I've installed Windows Server 2016, and found that there are missing network drivers.

Later I found one post, that downgrade firmware may help and downloaded this image:

https://downloads.hpe.com/pub/softlib2/software1/cd/p1040529012/v64851/firmware-9.30-0.zip

 

It was showing that it can downgrade three points, I pressed install and after that server rebooted and nothing happened.

Lamp on the monitor is blinking, seems something happened with drivers.

iLO access I don't know.

Please, help me how can I rollback firmware! Or reset bios.

Also in the front of server on health monitor, I see yellow blinking.

Thanks in advance.

SUM 8.4.1: Unable to upgrade SPS and IE firmware when using command line mode

$
0
0

We discovered that the newest SPP (2019.03) contains firmware updates for SPS (Server Platform Services) and IE (Innovation Engine).

Unfortunately it is not possible to apply them with SUM/smartupdate in command line mode. This has two reasons:

1) smartupdate requires does not list the necessary packages (firmware-spsgen10 and firmware-iegen10):

[root@server ~]# rpm -q sum
sum-8.4.1-1.rhel7.x86_64
[root@server ~]# smartupdate requires
firmware(hp:system:u30)
firmware(pci:v0000102Bd00000538sv00001590sd000000E4bc*sc*i*)
firmware(pci:v0000103Cd000022F6sv00001590sd000000E4bc*sc*i*)
firmware(pci:v0000103Cd00003306sv00001590sd000000E4bc*sc*i*)
firmware(pci:v0000103Cd00003307sv00001590sd000000E4bc*sc*i*)
firmware(pci:v00001077d00002261sv00001590sd000000F9bc*sc*i*)
firmware(pci:v00001077d00002261sv00001590sd000000F9bc*sc*i*)
firmware(pci:v000014E4d00001657sv0000103Csd000022BEbc*sc*i*)
firmware(pci:v000014E4d00001657sv0000103Csd000022BEbc*sc*i*)
firmware(pci:v000014E4d00001657sv0000103Csd000022BEbc*sc*i*)
firmware(pci:v000014E4d00001657sv0000103Csd000022BEbc*sc*i*)
firmware(pci:v000015B3d00001015sv00001590sd000000D4bc*sc*i*)
firmware(pci:v000015B3d00001015sv00001590sd000000D4bc*sc*i*)
firmware(pci:v00008086d00001572sv0000103Csd00000000bc*sc*i*)
firmware(pci:v00008086d00001572sv0000103Csd000022FCbc*sc*i*)
firmware(pci:v00008086d00002014sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002015sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002016sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002018sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002018sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002018sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002020sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002021sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002024sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002025sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002026sv00001590sd000018A9bc*sc*i*)
firmware(pci:v00008086d00002030sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002030sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002030sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002032sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002032sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002034sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002034sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002034sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002035sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002035sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002035sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002036sv00001590sd000018A9bc*sc*i*)
firmware(pci:v00008086d00002036sv00001590sd000018A9bc*sc*i*)
firmware(pci:v00008086d00002036sv00001590sd000018A9bc*sc*i*)
firmware(pci:v00008086d00002040sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002040sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002041sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002041sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002042sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002042sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002043sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002043sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002044sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002044sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002045sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002045sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002046sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002046sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002047sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002047sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002048sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002048sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002049sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002049sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Asv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Asv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Bsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Bsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Csv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000204Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002054sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002055sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002056sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002057sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002058sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002058sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002059sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002059sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002066sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002066sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002080sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002081sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002082sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002083sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002084sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002085sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d00002086sv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Dsv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000208Esv00001590sd000000EAbc*sc*i*)
firmware(pci:v00008086d0000A190sv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A194sv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1A1sv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1AFsv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1B1sv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1BAsv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1BEsv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1C1sv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1ECsv00001590sd000000EBbc*sc*i*)
firmware(pci:v00008086d0000A1EDsv00001590sd000000EBbc*sc*i*)
firmware(pci:v00009005d0000028Fsv0000103Csd00000602bc*sc*i*)
firmware-hdd-*
firmware-powerpic-*
firmware-sas-*
firmware-sata-*
firmware-smartarray-*
hp-firmware-hdd-*
hp-firmware-powerpic-*
hp-firmware-sas-*
hp-firmware-sata-*
hp-firmware-smartarray-*

It should also return firmware-spsgen10 and firmware-iegen10.

After we installed these two packages manually and tried to apply them, we got the following error:

[root@server ~]# yum install -y firmware-spsgen10 firmware-iegen10 > /dev/null
[root@server ~]# smartupdate upgrade sum : Smart Update Manager Version 8.4.1 Model: ProLiant DL380 Gen10, ROM: U30, ROM Version: 10/02/2018 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Searching for firmware............................................................................................................................................................................. Analyzing results............................................................................................................................................................................. The following firmware will be applied: Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers [0.2.0.11] Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers [04.01.04.251] The following firmware will be skipped (Use --downgrade or use --rewrite to apply.) HPE Intel Online Firmware Upgrade Utility for Linux x86_64 [1.16.0] Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10 Servers [1.0.4] HPE Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64 [2.22.3] Supplemental Update / Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10 [1.65] Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5 [1.37] Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers [U30 1.46 - (10/02/2018)] Do you want to apply them? [y] : y Deploy accepted successfully.Deployment started.....ERROR: Deployment failed to complete. Check SUM logs for more details... [root@sap00567 localhost]# cat /var/log/sum/localhost/SUM_InstallDetails.xml<?xml version="1.0" encoding="UTF-8"?><HPSUM_InstallDetails version="1.0"><NodeName>localhost</NodeName><NodeReturnCode>-3</NodeReturnCode><IsInstallerSuccess>false</IsInstallerSuccess><HasFailedDependencies>false</HasFailedDependencies><HasOmittedComponents>false</HasOmittedComponents><NodeStatus>Deploy error. Deploy skipped as one (or more) installables doesn't have compsig file.</NodeStatus><DryRun>false</DryRun><ComponentCount>0</ComponentCount><ComponentResults/></HPSUM_InstallDetails> [root@sap00567 sum]# cat /var/log/sum/SUM_Execution_Details_05-28-2019_12-52-16.xml<?xml version="1.0" encoding="UTF-8"?><SUM_Execution_Details version="1.0"><noderesults><node><status>Deploy error. Deploy skipped as one (or more) installables doesn't have compsig file.</status><name>localhost</name><status_code>SUM.8.4.0.DeploymentError</status_code><status_args></status_args><installsets><installset><name>System Recovery Set</name><size>84793235</size><description>Essential System Firmware Components</description><isRecovery>true</isRecovery></installset></installsets><returncode>-3</returncode><componentcount>8</componentcount><selectedcompcount>2</selectedcompcount><baselines><baseline><name>Additional Package</name><location>/tmp/sum-5HWOVZNMRCIC5DWO</location><version>N/A</version></baseline></baselines><error><message>Deploy skipped as one (or more) installables doesn't have compsig file.</message><code>SUM.8.4.0.CompsigMissingInstallables</code></error></node></noderesults><startuperror>false</startuperror><exitcode></exitcode><exitmessage></exitmessage><errorreport/><baselineresults><baseline><status>inventory_completed</status><name>Additional Package</name><missing_sigfile_components/><status_code>SUM.8.4.0.BaselineInventoryCompleted</status_code><location>/tmp/sum-5HWOVZNMRCIC5DWO</location><total_components_count>8</total_components_count><invalid_signature_components/><version>N/A</version><type>local</type><missing_components/></baseline></baselineresults>

If we try to apply them manually (execute setup script) it works without errors:

[root@server ~]# rpm -ql firmware-spsgen10 firmware-iegen10 | grep /setup
/usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.251-1.1/setup
/usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.0.11-1.1/setup
[root@server ~]# /usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.251-1.1/setup -s
[root@server ~]# /usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.0.11-1.1/setup -s
[root@server ~]#

We checked the versions via iLO and the updates were applied. 

DL380p Gen8 Cache Module Capacitor vs Battery

$
0
0

It seems some of these servers used battery packs and others used capacitors.  Which server configurations used capacitors?

Upgrading Smart Array P222 with SSDs: Failure Reason: "Hot Plug Drive Type Mix"

$
0
0

ProLiant DL320e Gen8 with Smart Array P222. It currently has 4x 1TB 7200 RPM SATA HDDs in a RAID 10 configuration. We are trying to upgrade these to 4x 1TB SSDs. When swapping the first one, the system fails the drive ( ADUReport says "The physical drive has failed"). The last failure reason is, "Hot Plug Drive Type Mix (0x25)".  This seems to imply that mixing the SSD with the other HDDs is not supported, which seems a bit weird to me, as I am under the impression these should be compatible. However, I can't seem to find any documention on this error code. Is that truly the issue and I really need to do something drastic like rebuild the whole server, or am I missing something?

 

Here is a snippet from the ADUReport. 

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Device Error Report

Device                                             Severity Error                          
-------------------------------------------------- -------- ------------------------------ 
Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 Critical The physical drive has failed.


Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Physical Drive Status

   SCSI Bus                             0 (0x00)
   SCSIID                               0 (0x00)
   Block Size                           512 Bytes Per Block (0x0200)
   Total Blocks                         1024.2 GB (0x773bd2b0)
   Reserved Blocks                      0x00010000
   Drive Model                          ATA     Samsung SSD 860 
   Drive Serial Number                  S45ENF0M301064R     
   Drive Firmware Revision              RVM01B6Q
   SCSI Inquiry Bits                    0x02
   Compaq Drive Stamped                 Stamped For Monitoring (0x01)
   Last Failure Reason                  Hot Plug Drive Type Mix (0x25)
   Device Flags                         0x00
   More Device Flags                    0xa5
                                        Position Device Flag                            Status        
                                        -------- -------------------------------------- ------------- 
                                        0        SMART Predictive Failure Supported     Informational 
                                        2        SMART Predictive Failure Is Enabled    Informational 
                                        5        Configured Data Drive                  Informational 
                                        7        Write Cache Enabled In Saved Mode Page Informational 

   SCSI Lun                             0x00
   Yet More Device Flags                0xa0
                                        Position Device Flag                             Status        
                                        -------- --------------------------------------- ------------- 
                                        5        Does Not Support Redundant Controllers  Warning       
                                        7        Drive Write Cache Setting Is Changeable Informational 

   Even More Device Flags               0xd0
                                        Position Device Flag                 Status        
                                        -------- --------------------------- ------------- 
                                        4        PHY To PHY Map Is Supported Informational 
                                        6        Ncq Capable                 Informational 
                                        7        Ncq Enabled                 Informational 

   Spi Speed Rules                      0x00000000
   Physical Port                        2I
   Physical Box                         1 (0x01)
   Physical Bay                         1 (0x01)
   RPM                                  0 RPM (0x00000001)
   Device Type                          SATA SSD (0x01)
   SATA Version                         0x00
   Big Total Block Count                0x00000000773bd2b0
   RIS Starting LBA                     0x00000000773adab0
   RIS Size                             160 KB (0x00000140)
.......
   Minimum Good Firmware Revision       empty
   Vendor Unique Inquiry Bytes          All Zeroes (20 x [0x00])
   Current Temperature                  0xff
   Temperature Threshold                0x3c
   Maximum Temperature                  0x31
   Logical Blocks Per Physical Block    0x00
   Current Q Depth Limit                0x0010
   Switch Name                          All Zeroes (10 x [0x00])
   Switch Port                          0x0000
   Alternate Paths Switch Name          All Zeroes (40 x [0x00])
   Alternate Paths Switch Port          0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Power On Hours                       0x0000
   Percent Endurance Used               0x0000
   Drive Authentication                 0x00
   Smart Carrier Authentication         0x00
   Smart Carrier Application Version    0x00
   Smart Carrier Bootloader Version     0x00
   Sanititze Erase Support              0x00
   Encryption Flags                     0x00
  
Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : SmartSSD Wear Gauge

   Status                               FAILED
   Supported                            FALSE

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Monitor and Performance Statistics (Since Factory)

   Command Status                       0x0001
   SCSI Status                          0x02
   Sense Key                            0x05
   ASC                                  0x3a
   ASCQ                                 0x00

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Monitor and Performance Statistics (Since Factory - Cached Values)

   Serial Number                        empty
   Firmware Revision                    empty
   Product Revision                     empty
   Reference Time                       0x00000000
   Sectors Read                         0x0000000000000000
   Read Errors Hard                     0x00000000
   Read Errors Retry Recovered          0x00000000
   Read Errors ECC Corrected            0x0000000000000000
   Sectors Written                      0x0000000000000005
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000000
   Seek Count                           0xffffffffffffffff
   Seek Errors                          0xffffffffffffffff
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0xffff
   Performance Test 3                   0xffff
   Performance Test 4                   0xffff
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0xffffffff
   DRQ Time Outs                        0xffff
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0000
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0xffff
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0xffffffff
   IRQ Deglitch Count                   4294967295 (0xffffffff)
   Bus Faults                           0x00000000
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0000
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Monitor and Performance Statistics (Since Reset)

   Command Status                       0x0001
   SCSI Status                          0x02
   Sense Key                            0x05
   ASC                                  0x3a
   ASCQ                                 0x00

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Monitor and Performance Statistics (Since Reset - Cached Values)

   Serial Number                        empty
   Firmware Revision                    empty
   Product Revision                     empty
   Reference Time                       0x00000000
   Sectors Read                         0x0000000000000000
   Read Errors Hard                     0x00000000
   Read Errors Retry Recovered          0x00000000
   Read Errors ECC Corrected            0x0000000000000000
   Sectors Written                      0x0000000000000005
   Write Errors Hard                    0x00000000
   Write Errors Retry Recovered         0x00000000
   Seek Count                           0xffffffffffffffff
   Seek Errors                          0xffffffffffffffff
   Spin Cycles                          0x00000000
   Spin Up Time                         0x0000
   Performance Test 1                   0x0000
   Performance Test 2                   0xffff
   Performance Test 3                   0xffff
   Performance Test 4                   0xffff
   Reallocation Sectors                 0xffffffff
   Reallocated Sectors                  0xffffffff
   DRQ Time Outs                        0xffff
   Other Time Outs                      0x0000
   Drive Rebuild Count                  0 (0x0000)
   Spin Retries                         65535 (0xffff)
   Recovers Failed Read                 0x0000
   Recovers Failed Write                0x0000
   Format Errors                        0x0000
   Self Test Failures                   0xffff
   Not Ready Failures                   0x00000000
   Remap Abort Failures                 0xffffffff
   IRQ Deglitch Count                   4294967295 (0xffffffff)
   Bus Faults                           0x00000000
   Hot Plug Count                       0 (0x00000000)
   Track Rewrite Errors                 0xffff
   Write Errors After Remap             0x0000
   Background Firmware Revision         0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
   Media Failures                       0x0000
   Hardware Errors                      0x0000
   Aborted Command Failures             0x0000
   Spin Up Failures                     0x0000
   Bad Target Count                     0 (0x0000)
   Predictive Failure Errors            0x00000000

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Serial SCSI Physical Drive Error Log

   Command Status                       0x0001
   SCSI Status                          0x02
   Sense Key                            0x05
   ASC                                  0x3a
   ASCQ                                 0x00

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : Mode Sense 10

   Low Level Status                     0x80000004

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : VPD Page 80 - Serial Number

   Low Level Status                     0x80000004

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1024.2 GB Solid State SATA) 2I:1:1 : VPD Page 83 - Array Information

   Low Level Status                     0x80000004

Smart Array P222 in slot 2 : Internal Drive Cage at Port 2I : Box 1 : Drive Cage on Port 2I : Physical Drive (1 TB SATA) 2I:1:2 : Physical Drive Status

   SCSI Bus                             0 (0x00)
   SCSIID                               1 (0x01)
   Block Size                           512 Bytes Per Block (0x0200)
   Total Blocks                         1 TB (0x74706db0)
   Reserved Blocks                      0x00010000
   Drive Model                          ATA     MB1000GCEHH     
   Drive Serial Number                  Z1N44ZZS            
   Drive Firmware Revision              HPGD    
   SCSI Inquiry Bits                    0x02
   Compaq Drive Stamped                 Stamped For Monitoring (0x01)
   Last Failure Reason                  No Failure (0x00)
   Device Flags                         0x01
                                        Position Device Flag                   Status        
                                        -------- ----------------------------- ------------- 
                                        0        Drive Present And Operational Informational 

   More Device Flags                    0x25
                                        Position Device Flag                           Status        
                                        -------- ------------------------------------- ------------- 
                                        0        SMART Predictive Failure Supported    Informational 
                                        2        SMART Predictive Failure Is Enabled   Informational 
                                        4        Device Attached To Internal Connector Informational 
                                        5        Configured Data Drive                 Informational 

   SCSI Lun                             0x00
   Yet More Device Flags                0xa0
                                        Position Device Flag                             Status        
                                        -------- --------------------------------------- ------------- 
                                        5        Does Not Support Redundant Controllers  Warning       
                                        7        Drive Write Cache Setting Is Changeable Informational 

   Even More Device Flags               0xd0
                                        Position Device Flag                 Status        
                                        -------- --------------------------- ------------- 
                                        4        PHY To PHY Map Is Supported Informational 
                                        6        Ncq Capable                 Informational 
                                        7        Ncq Enabled                 Informational 

   Spi Speed Rules                      0x00000000
   Physical Port                        2I
   Physical Box                         1 (0x01)
   Physical Bay                         2 (0x02)
   RPM                                  7200 RPM (0x00001c22)
   Device Type                          SATA (0x01)
   SATA Version                         0x00
   Big Total Block Count                0x0000000074706db0
   RIS Starting LBA                     0x00000000746f75b0
   RIS Size                             160 KB (0x00000140)
....

 

Trying to update HP ProLiant DL 120 Gen9 server SPP via offline remotely not locally

$
0
0

Hi community out there,

I would like to update System ROM of the server DL 120 Gen9, its good to update SPP so everthing will get updated. Current version of the System Rom is : P86 v2.00 (12/28/2015) and only  ILO  Firmware verison  before i alreday updated via HP ILO and ILO Firmware version: 2.62 Jan 09 2019.

I attached the ISO of SPP then reset server, went to boot menu F11 option then select HP ILO virtual USB/CD and hit enter. HP logo appeared then select Automatic (alreday did steps with other Bladeserver and it works) then after stuck at place where it shows "mouting a root file system, please wait" then after couple of minutes it same progress percentage without any progress then i restarted server without iso. Could be case ISO file is different location and server is in different location that's why taking time becuase of not local avaible of file but i dont think so that could impact a lot.

 

Thanks 

Syed

 

 

 

 

Windows Essentials 2016 ISO install on DL360 Gen10

$
0
0

Hello,

I am having problems installing Win Essentials 2016 from an ISO by using Intelligent Provisioning Express OS Install.  I copy the ISO to a exFat USB, but the install warns me that the selected OS does not support this install source and I do not get the option of the next button.  I would be greatful for any tips on how to solve this issue. 


HP Proliant G8 not detecting USB devices

$
0
0

we have a proliant G9 NAS Storage in which it is when we connect to USB ports its not detecting and even the remote desktop were also not accessable. checked on the registry configuration as well, all were with default configuration..

suggest & Advice !!

HP P420 Firmware Flash

$
0
0

HI All,

Apologies if I have posted this in the wrong place. I couldn't find a location for storage controllers specifically.

I have a HP P420 Smart Array Controller in a HP Proliant ML310e Gen8, which is being recognised in the BIOS but is not being recognised in the HP SmartArray Configuration utility. I have a feeling the firmware on the card may be corrupted...

I have attempted to flash the firmware on the card via HP SPP but it gives an error (see below). When the SPP highlights that the controller requires an update the current version of firmware is blank. I have tried using the advanced options of rewrite, downgrade etc which produces the same error

Exit Status: 3
Update not attempted. All selected devices are either up-to-date or have new versions installed.

I have also booted a CentOS 7 liveCD and attempted to flash the firmware in terminal with all the switches for rewrite, downgrade, force but still it produces the same error as above

Is the controller broken and I am wasting my time, or is there a way I could flash the firmware back and salvage the card?

Any suggestions would be greatly appreciated.

Thanks in advance

Joe

DL360 G10 - Single RIser and 2 x Dual Port Ethernet cards

$
0
0

Hello,

Will the following configuration work - willl the bus on the riser support it:

DL360 G10 with a single CPU and single riser

2 x  HPE Ethernet 10/25Gb 2-port 640SFP28 Adapter - in PCI slots or riser

1 x HPE Ethernet 10/25Gb 2-port 640FLR-SFP28 Adapter in FlexLOM port

 

I'm concerned that the single riser may not have the bandwidth to support the 2 x 25G PCI cards together

 

Any help would be greatly appreciated

Regards

 

DL360 G7 unable to boot from internal USB

$
0
0

Hi All,

I have a DL360 G7, it has 3 internal SSD drives which I have configured with RAID5 within SmartArray. I have a 16GB SanDisk Cruzer fit that I inserted into the internal USB port. BIOS configuration is currently set to default.

I installed ESXi 6.7 on the internal USB port and upon installation of ESXi, i pressed 'SHIFT+O' to change the format to 'formatwithmbr' as I have found out (googling) that HP will not boot if the disk is formatted with GPT.

The installation was successful and server rebooted, however, it will not boot from the internal USB. I have included a frew screenshots of what I see right after first reboot after installation.

Any help is appreciated.

Update Blade BIOS without OS through SUM

$
0
0

Hello,

I am wondering if is possible to update the BIOS of a collection of Blades throgh the Smart Update Manager (SUM) if there is no O.S. installed on the blades. If I add the blades to SUM as iLO node I can update the only the iLO.

Cheers!